2
10
bintec User’s Guide
Frame Relay
Link Configuration Submenu
Polling Interval
When
dte
mode (client) is set and
L
INE
M
ANAGEMENT
is enabled, this field determines
the number of seconds between successive
status enquiry messages sent by the gateway.
Possible values:
5 .. 30
.
Default value:
10
.
Full Enquiry Interval
When
dte
mode (client) is set and
L
INE
M
ANAGEMENT
is enabled, this field determines
the number of status enquiry intervals that pass
before issuing a full status enquiry message.
Possible values:
1 .. 255
.
Default values:
6
.
Idle Interval
When
dce
mode (server) is set and
L
INE
M
ANAGEMENT
is enabled, this field defines the
space of time in seconds within which status
enquiry messages should be received.
Possible values:
10 .. 60
.
Default value:
15
.
Error Threshold
When
L
INE
M
ANAGEMENT
is enabled, this field
defines the maximum number of unanswered
Status Enquiries the gateway accepts before
declaring the interface down.
Possible values:
1 .. 10
.
Default value:
3
.
Field
Description