Страница 1: ...TRM 810 RTU 810 RTU 81 User Guide Funk Electronic Piciorgros GmbH Claudiastrasse 5 51149 Cologne Germany...

Страница 2: ...3 Ethernet Interface 16 2 2 4 Extension Port for additional I O modules only devices with embedded I O 16 2 2 5 Connecting the I O RTU 810 DAx types only 17 2 2 6 Connecting the Antenna 20 2 3 LED Fun...

Страница 3: ...93 4 1 1 Tunneling a serial connection with the SIG 810 Q2 3 2017 93 4 1 2 Operating modes 94 4 1 3 Address detection and routing 95 4 1 4 Configuring the IP link 96 4 1 5 IP link status information 9...

Страница 4: ...mands 112 6 2 Accessing the I O using the IEC60870 protocol Future option 113 6 2 1 Native internal IEC60870 support for the basic I O s 113 7 PICOLOGO USER APPLICATION INTERFACE 114 8 TROUBLESHOOTING...

Страница 5: ...should be taken to ensure that the radio and antenna systems are installed and commissioned only by trained persons This radio equipment should not be used in life support systems or in safety systems...

Страница 6: ...4 MHz with a transmit power of up to 10mW It also has only a fixed internal I O setup of 8 binary inputs 8 binary outputs and 2 analog inputs Apart from this it has the same features as the RTU 810 In...

Страница 7: ...10 DA3 Radio modem with two serial ports one Ethernet port 16DI 16DO no embedded AI and an expansion port connector for PEM type expansion modules with additional I O RTU 810 DA4 Radio modem with two...

Страница 8: ...RTU 810 V2 30 Page 8 of 126 By default the RTU 810 will be delivered with two serial RS 232 ports RS 422 or RS 485 are options which must be provided with the order They can t be activated or changed...

Страница 9: ...ace The PicoLogo option is a powerful User Application Interface that can be used similar to a Micro PLC to generate Alarms Text Messages M2M Communication or to monitor and supervise digital or analo...

Страница 10: ...available in short or mid term These features are described in blue paragraphs Related hardware devices and hardware options will be GSM LTE option for the RTU 810 SIG 810 Serial to IP Gateway for tun...

Страница 11: ...V2 30 Page 11 of 126 1 9 Document Changes The history of this documentation is listed below Firmware Version Document Version Comments Changes 2 30 2 30 Initial Document Release Software Release Notes...

Страница 12: ...provided to connect PEM I O expansion modules Also on the upper side of the unit the plug in terminal connector for the power supply 12 24 VDC 20 and a BNC socket for the antenna can be found RTU 810...

Страница 13: ...lted downward slightly The Module is then pushed upward 1 and rotated backward 2 until the upper lip of the clip snaps onto the upper flange of the DIN rail 2 1 3 Dismounting To dismount the Module fo...

Страница 14: ...nnected through 3 way screw terminal connector located on the upper side of the enclosure The terminals are assigned as follows viewed from the front of the module facing the front panel Outer left En...

Страница 15: ...ng is 9600 bps 8 data bits no parity 1 stop bit If a frame error is detected or if the parity bit does not conform to the setting the received data block is rejected Pin No Pin Assignment RS 232 2 TxD...

Страница 16: ...xtension Port for additional I O modules only devices with embedded I O The I O expansion connector is located at the upper right part of the RTU 810 of all TMO versions with embedded I O The connecto...

Страница 17: ...nal If the C terminal is connected to the ground the inputs will be active if the positive voltage 12 14V applies If the C terminal is connected to the positive voltage the inputs are activated by app...

Страница 18: ...supply must be provided externally in the loop The input range is 0 20mA with a resolution of 12 bit Analog outputs DA4 DA5 type The analog outputs are an active source for 0 20mA which means that i e...

Страница 19: ...Funk Electronic Piciorgros GmbH RTU 810 V2 30 Page 19 of 126 2 2 6 Connection diagram RTU 81...

Страница 20: ...requency The antenna cable 50 ohm should not be longer than 5 meters and should be good quality low loss type RG 213 or Aircell Overvoltage protection suitable for protecting the modem is available Th...

Страница 21: ...e 21 of 126 2 3 LED Functions Groups of LED lamps on the front panel of the RTU 810 indicate the operating condition of the modem the field strength of the received radio signal and error conditions i...

Страница 22: ...RTU 810 sends data via the COM interface COM Rx Lights up while the RTU 810 receives data via the COM interface AUX Tx Lights up while the RTU 810 sends data via the AUX interface AUX Tx Lights up whi...

Страница 23: ...S 100 time server Permanently on The time synchronization is up to date and time slot operation can be used Mostly off with an on blip every second DCF PTS 100 only The RTU 810 is waiting for the seco...

Страница 24: ...ils MSG If the RTU 810 has a GSM option this LED lights up if a SMS is being transmitted or received GSM If the RTU 810 has a GSM option this LED shows the registration status of the GSM module Slow 1...

Страница 25: ...168 0 199 20 regardless of the configured Ethernet IP address Long flash short flash alternating The device is processing or performing a firmware update 4 blinks then pause The internal radio module...

Страница 26: ...l then perform a reset to factory defaults 2 5 Temporary reset to default IP address If the IP address of a RTU 810 is unknown it can be temporarily reset to the default address Press for one second o...

Страница 27: ...0 0 If the IP address of the RTU 810 is typed into the web browser the login page will appear The first login will be done using the default username and password take care as both are case sensitive...

Страница 28: ...Funk Electronic Piciorgros GmbH RTU 810 V2 30 Page 28 of 126 After 5 minutes without activity the user will be automatically logged out...

Страница 29: ...ctronic Piciorgros GmbH RTU 810 V2 30 Page 29 of 126 3 1 1 Navigation using the Menu To select a menu move the cursor over the desired headword and click it Then the menu will open displaying the next...

Страница 30: ...s which have been transmitted initially Note that a Reset will not work after the changes have been applied Note Instead of clicking Apply pressing the Enter key will have the same function on most pa...

Страница 31: ...An easy way to continue the configuration session is to reload the page by hitting the F5 key 3 1 5 Recommended Web Browsers For the configuration of the RTU 810 these Browsers are recommended Mozilla...

Страница 32: ...3 2 Radio configuration This section explains the radio configuration of the RTU 810 Most important thing to start with is to set the correct radio frequency and transmit power 3 2 1 Configuration The...

Страница 33: ...n t send or transmit data to the own radio network This radio layer address is displayed here It is a 4 digit hexadecimal number Variable address A customer can apply for a radio layer address range i...

Страница 34: ...the hardware is listed below this field The frequency must be a multiple of 12 5 kHz If this is not the case the entered frequency will be automatically corrected when the page is applied Output power...

Страница 35: ...he own radio among the general RSSI of the data traffic on this frequency Peak hold expire If for this amount of minutes no access to the RTU 810 has occurred the peak hold LED will start to flash A f...

Страница 36: ...ted Value instead of a calibrated dBm value The device ID will not be 0x0800 to indicate it s an RTU 810 it s instead reporting the old ID from the 710 series RTU 810 DA1 0x0011 RTU 710 DA1 RTU 810 DA...

Страница 37: ...RTU master mode is used to achieve point to point or point to multipoint connections the routing table which should be used can be directly selected for each slave For the serial master modes the used...

Страница 38: ...would be Data which should be sent to slave address 1 will take this route RTU 810 slave addr 2 slave addr 7 slave addr 1 Data which should be sent to slave address 2 will take this route RTU 810 sla...

Страница 39: ...are configured to the particular failed slave will be switched to OFF The digital and analog outputs of the respective slave are also written to OFF by the RTU 810 master If the radio link to the sla...

Страница 40: ...g polled itself it will set its outputs to OFF state 0 disables the X timeout at the slaves Delay after each station polling If this value is greater than 0 the RTU 810 will wait this number of second...

Страница 41: ...nsmitted from the master RTU 810 to the remote slave Routing table Determines which radio routing table should be used to route the radio telegrams to the particular slave This will be changed from so...

Страница 42: ...s on port A0 A3 of the slave 1 will now be transferred to the outputs C0 C3 of the master RTU 810 At the same time the valid range for the same parameter on the following slaves have been updated The...

Страница 43: ...at once it ll be possible to enter more I O in total as are available on the master RTU 810 In this case after pressing Apply an error message will indicate this fact on the page The communication to...

Страница 44: ...CADA routing tables with its IP entry do have the ability to specify an IP address beside the radio slave address In the slave configuration a selection for each slave will be added to configure wheth...

Страница 45: ...able information about the slave like available physical I O etc The slave will be automatically set to the same family address as the master and will have a slave address automatically assigned Final...

Страница 46: ...ronic Piciorgros GmbH RTU 810 V2 30 Page 46 of 126 The automatically configured setup will be available in the RTU Master Mode configuration page afterwards It can be modified and fine tuned anytime a...

Страница 47: ...connection to the RTU 810 is a DCF 77 coded signal hence it requires the DCF or PTS option at the RTU 810 DCF 77 The DCF option is a hardware option and includes a socket for an active DCF 77 antenna...

Страница 48: ...t configuration This selects any of the 10 available time slots for radio operation If all time slots are set to off the RTU 810 operates in continuous operation Each 6 seconds time slot can be furthe...

Страница 49: ...not possible to monitor devices from other customers on the same frequency or to communicate with them The RSSI monitor will not list any alien devices outside the own radio networks The RSSI monitor...

Страница 50: ...can be used to set the threshold for the Low RSSI counts in a range between 60 and 140 dBm Note Clicking Apply on this page will reset all collected statistics If the RSSi monitor values just should...

Страница 51: ...be used to identify the device It can also be used as a placeholder in PicoLogo TextSend blocks PicoLogo state State of the internal PicoLogo application This can be Stopped Running or Error Parse for...

Страница 52: ...face The settings of the COM and AUX serial interfaces are identical therefore both are described in this chapter Both interfaces can operate completely separated from each other so two different serv...

Страница 53: ...data via the serial interface is treated as MODBUS RTU data The RTU 810 will answer them locally if a MODBUS RTU telegram addressed to the local MODBUS address of the RTU 810 is seen on the interface...

Страница 54: ...ace will use the IP address which is determined from the selected SCADA routing table If the IP address is 0 0 0 0 no data will be sent In Mixed mode the slaves can be partially in the radio network a...

Страница 55: ...col will run on the particular interface Communication protocol used on COM AUX Selects a known SCADA protocol User defined protocol gives the ability to define the position and format of the address...

Страница 56: ...But any number of bits between 1 and 32 will work here in case the address is only a part of a byte or a word Offset address bit In case the address does not start with bit 0 LSB of a byte an offset t...

Страница 57: ...ble to determine the radio slave address to which the data should be sent This option can be used to override these mechanisms If all fields are set to 0 the protocol extraction routing tables are use...

Страница 58: ...al parameter settings This configures the serial parameters for the serial interface Baudrate The baud rate of the interface in the range between 300 and 57600 bit s Databit The number of data bits pe...

Страница 59: ...transparent communication Once the first character is received on the interface a timer is set counting down milliseconds With each character which is received before this timer runs out the characte...

Страница 60: ...application interface is to name it as a serial interface but with a different physics It can i e be used to use an IP LAN network where otherwise a very long serial cable would be needed to connect t...

Страница 61: ...ly the listening port must be defined further down TCP client The interface will act as a TCP client and opens a TCP connection to a given IP address and port If the connection can t be established th...

Страница 62: ...on of the Radio addr and IP address fields are optional By default the SCADA addresses 1 239 are preset with radio slave addresses 1 239 all other fields are set to 0 3 3 4 1 Browse page As only 10 20...

Страница 63: ...logical address is set to a certain value the ID number is the result of the extracted SCADA address minus the value of the first logical address field in the interface IP address IP address of the s...

Страница 64: ...able reset option When CLR is types in this field and then Apply is clicked the SCADA routing table will be restored to default state This means a 1 1 routing for SCADA addresses 1 239 to radio slave...

Страница 65: ...he port needs a device restart MODBUS IP Active Turns the MODBUS IP function On or Off A change needs a device restart MODBUS IP protocol Selects the use of UDP or TCP for the MODBUS IP access Default...

Страница 66: ...6 1 Internal clock Date The current date in format DD MM YYYY To set the date to a different value the data can be entered in these fields Internal time Current time in 24h format It requires a page r...

Страница 67: ...e internal real time clock and the internal time slot synchronization This method is eligible as a clock source for time slot operation mode SNTP server IP The IP address of the SNTP time server This...

Страница 68: ...nternet or should access the internet or other devices in the LAN by itself using a router In this case the IP address of the router must be entered here The standard gateway must be in the same IP su...

Страница 69: ...the email address which is used in the From field of the email and in the email envelope during transmission to the email server AUTH username This is the username which is used for SMTP authenticatio...

Страница 70: ...up The RTU 810 can send logger messages and events to a SYSLOG server via the SNMP trap protocol It does not support management by SNMP Messages are sent via UDP to port 162 of the given syslog server...

Страница 71: ...serial master mode ZZTR ZZTRM can be used If the RTU 810 receives a ZZTR telegram it will check if this is a MODBUS RTU datagram when this option is turned on If the MODBUS address is matching the RT...

Страница 72: ...y connected equipment will write into these registers Local equipment can read write these registers from MODBUS address 650 689 For remote equipment these will be seen as common analog inputs The vir...

Страница 73: ...or a MDP 310 200 can change if the number of available I O is changing I e the virtual analog outputs will shift back to a different register address if an expansion module with analog outputs is add...

Страница 74: ...TU 810 s start and each time the RTU 810 is accessed by a master regardless which protocol the access is using DNP3 IEC 60870 MODBUS and regardless of the interface which was used radio GSM Ethernet s...

Страница 75: ...ry inputs Inputs provided by expansion modules do not provide advanced functions 3 5 2 1 Browse page As only 10 entries are displayed per page but the configuration table holds a maximum of 16 entries...

Страница 76: ...time unit is 100ms This function can be used to suppress glitches Any delays configured here will be applied before any other processing functions like SCADA queries or PicoLogo Num Number of the inpu...

Страница 77: ...he maximum frequency is 10 Hz This can be used as a pulse counter Configured as a time counter the counting register will be increased by 1 in every second the input is active Resolution is 100ms The...

Страница 78: ...N mode This switch is non volatile and the setting is preserved during a power down of the RTU 810 3 6 1 2 PicoLogo status This section indicates the status of the PicoLogo application STOPPED No Pico...

Страница 79: ...al the run time version in the RTU 810 Device ID The device ID of the RTU 810 ID of program The device ID for which the application was compiled Program name The name which was used to store the appli...

Страница 80: ...orgros GmbH RTU 810 V2 30 Page 80 of 126 3 6 1 4 Erase program A loaded PicoLogo application can be erased here For security reasons the word Delete must be typed into the text field and Apply must be...

Страница 81: ...ition these addresses can be viewed and edited in the contact table 3 6 2 1 Browse page As only 10 entries are displayed per page but the contact holds a maximum of 50 entries the start index of each...

Страница 82: ...r contact is opened To make destination addresses for messages easily changeable without recompiling the whole application in the PicoLogo editor addresses are listed in the contact table The applicat...

Страница 83: ...for an easy on the fly change 3 6 3 1 Browse page As only 10 entries are displayed per page but the parameters section can hold more entries the start index of each page can be entered here A click o...

Страница 84: ...an be put into the web server for easy reviewing and changing In this case the checkbox Description visible in web server must be checked for the constants in the PicoLogo block as done in the applica...

Страница 85: ...is the contact information of Piciorgros GmbH After login the RTU 810 web server comes up with this page 3 7 2 Manage password This changes the password of the current logged in user The password must...

Страница 86: ...bH RTU 810 V2 30 Page 86 of 126 3 7 3 Configuration This page allows some configuration for the Protocol Logger Event logger can show the status of the additional RTU 810 features and can be used to e...

Страница 87: ...res up to 650 events like communications failures for the RTU master mode device restarts and much more The entries are nonvolatile and survive power downs If 650 entries are stored each new entry wil...

Страница 88: ...an have this status announced Enabled The feature is permanently enabled and can be used Temporary This feature is in trial mode for a certain time The remaining time is also listed After the remainin...

Страница 89: ...or which it was ordered In this example an activation key is purchased to turn the serial master mode activation into a permanent one and to activate the RTU master mode feature This is the situation...

Страница 90: ...to reset if to factory default Restart A click on this button restarts the RTU 810 Reset to factory default A click on this button does a full reset to factory defaults Any customer settings are erase...

Страница 91: ...The register addresses are identical to the MODBUS register addresses therefore it can be used to check the content of the I O registers Also in a support case you might be asked to read out certain...

Страница 92: ...The event logger stores events and exceptions communication failures in RTU master mode and much more This is the first point to check if the communication to a RTU 810 was disturbed or if other prob...

Страница 93: ...es All IP data must be addressed to the RTU 810 as the IP connection is just locally To route the data to different destinations in the radio network the known mechanism of address detection and the u...

Страница 94: ...4 of 126 4 1 2 Operating modes The operating modes available for the IP Application Interface are exactly the same as for the serial ports they are not described here again in detail For a detailed de...

Страница 95: ...inside the data payload received on the interface This may be common and known serial SCADA protocols which are embedded in the IP packet to the RTU 810 but also customer specific data containing an a...

Страница 96: ...d for a receiver device the RTU 810 will learn the source IP and port of the last packet which was sent to it and send any received data for the IP Application Interface back to it If an IP port is co...

Страница 97: ...ction it can be used to send and receive data 4 1 5 IP link status information On top of the configuration page the status of the connection can be seen In TCP modes the status is CONNECTED once a TCP...

Страница 98: ...of setup is an IP link between the RGW 810 and the radio master which can be a RTU 810 a TRM 810 a RTU 81 or by end of 2017 the MDP 810 The RGW 810 includes a configurable radio part similar to the RT...

Страница 99: ...each other was covered by the ability to give a block of radio layer addresses to a customer where he can select one of the addresses inside this range by his own For the 810 series we ll introduce th...

Страница 100: ...dio gateway to use remote parts of the radio network via this connection in case no local Ethernet connection is in place It can also communicate directly with other RTU 810 via IP in a Point to Multi...

Страница 101: ...via SMS Commands can be sent to the RTU 810 via MMI message Man Machine Interface requesting the receive field strength in the GSM network switching binary outputs setting analog outputs or query the...

Страница 102: ...a received over a predefined period of time Factory default is set to 10 ms for 9600 bps That reflects 10 characters in sequence Basically if used other baud rates a timeout period of 10 character tim...

Страница 103: ...yte s is are located With that knowledge the RTU 810 extracts this logical address byte and using the predefined address translation or routing table it can convert the protocol address into the desti...

Страница 104: ...ally Outstations can send data at any time to the master device unsolicited messaging With the 60870 DNP3 option this protocol can also be used to access the RTU 810 itself Future option 5 2 4 IEC 608...

Страница 105: ...ted or where the Address Range exceeds the RTU 810 storage spectrum 1024 entries e g sometimes that can happen using the HART protocol can be transmitted in the broadcast mode T1X Future option In thi...

Страница 106: ...Page 106 of 126 5 3 IP based Communication Protocols In the future it is planned to have the ability to also transport IP based protocols using the TRM 810 RTU 810 This will be a firmware update toge...

Страница 107: ...e is 10 Hz The control and measurement I O can be accessed using any of the following protocols MoP MoP2 This is the Piciorgros radio protocol which is used to access the RTU 810 from a serial master...

Страница 108: ...follows Bit 7 Will be set on device restart The bit can be cleared if the status register is written with a value where bit 7 is set Bit 6 A set bit means that an I O error has occurred This can be a...

Страница 109: ...cted equipment Refer to 3 5 1 3 Virtual analog I O 750 799 Digital outputs I O port C0 is the LSB 800 899 Analog Outputs if present first value reflects input D0 Virtual analog outputs are added after...

Страница 110: ...ynchronized time slot use possible Bit 3 1 Time base currently not synchronized but in reserve mode Time slot use is still possible Bit 4 1 DCF is in decoding process 1434 Remaining sync reserve Numbe...

Страница 111: ...6 Radio slave address Configured radio slave address 1737 914 Last data RSSI RSSI of the latest received data in dBm Will be an uncalibrated value in RTU 710 compatibility mode 1745 900 Radio Layer ad...

Страница 112: ...ed by the RTU 810 Command Description 1 0x01 Read Coil Status 2 0x02 Read Input Status 3 0x03 Read Holding Registers 4 0x04 Read Input Registers 5 0x05 Force Single Coil 6 0x06 Write Single Register 8...

Страница 113: ...2 80 There are two ways of accessing the I O of the RTU 810 with IEC60870 protocol which are explained below 6 2 1 Native internal IEC60870 support for the basic I O s If the IEC60870 option is active...

Страница 114: ...latform that can be used to combine the embedded I O with logic functions set up M2M communication send text and alarm messages to cellphones GSM option required or SNTP trap messages to syslog server...

Страница 115: ...RTU 810 can be saved to the computer to have a configuration backup or to clone the configuration to other RTU 810 The IPLoader software is needed for this 8 1 1 Configuration download from the RTU 81...

Страница 116: ...30 Page 116 of 126 Specify a location on the computer where the file should be stored and give config tmo as the file name A progress bar will be shown below the button to indicate the transfer is ong...

Страница 117: ...ardware version This gives you the ability to restore the exact configuration if someone has broken it or to upload the configuration into other RTU 810 s to clone a certain configuration If the confi...

Страница 118: ...Funk Electronic Piciorgros GmbH RTU 810 V2 30 Page 118 of 126 Followed by a success message The RTU 810 will automatically restart to apply the new configuration...

Страница 119: ...ken with the software IPlogger This requires an Ethernet connection of the PC running the IPLogger to the RTU 810 Due to the high amount of data don t use the IPLogger over a WAN or internet connectio...

Страница 120: ...Funk Electronic Piciorgros GmbH RTU 810 V2 30 Page 120 of 126 The extension log should be kept Finally the button Start can be pressed to start the logging...

Страница 121: ...Even when the IPLogger is restarted it will always append its data at the end of the specified log file If the log file should be cleared press the button Clear file This can be done during a running...

Страница 122: ...e RTU 810 main firmware The RTU 810 firmware is a single file with the extension pfo To update the RTU 810 it must be connected to the PC via Ethernet The software version in the RTU 810 can be checke...

Страница 123: ...orgros GmbH RTU 810 V2 30 Page 123 of 126 In the IPLoader the IP address of the RTU 810 must be entered in the IP network field Then the button Firmware update must be clicked Select the RTU 810 firmw...

Страница 124: ...nk LED on the Ethernet plug will go off for approximately around 30 seconds Important During the internal reprogramming DO NOT INTERRUPT THE POWER TO THE RTU 810 Otherwise the RTU 810 will not start a...

Страница 125: ...860 870 MHz M RTU 81 433 434 MHz Receiver Sensitivity SN typ 1 2uV f r 20dB dF 2 4kHz fm 1kHz SINAD typ 0 5uV CCITT Filter dF 2 4kHz fm 1kHz Interfaces COM AUX Ethernet RS 232 or RS 485 422 Sub D F R...

Страница 126: ...he radio network via RGW 810 radio gateway Protocols MODBUS RTU MODBUS TCP IEC 60870 5 101 IEC 60870 5 104 DNP3 DNP3 IP PakBus Siemens Sinaut BSAP RP570 Custom protocols serial or IP based RF Conforma...