3. The motor is connected to a tri-colored wire. Disconnect the wire before continuing.
Fig. 30
Note: Some wires may be covered in hot-melt adhesive to prevent separation.
4. Remove the screws holding the motor in place ( see Fig. 28).
5. Remove and replace the motor.
6. Replace the screw and reconnect the wire.
Note: It is recommended to secure the wires some way to prevent separation.
7. Turn on the machine and once again go to the set up page.Then go to the “Laser Tools Tab”.
8. There will be a section for Camera Shutter Position. Set the open value to 1.7 and the closed value to 1.3.
9. Test both values and adjust the shutter accordingly(see Fig. 31).
Fig. 31
44