The reported data refer to laboratory tests: several factors can influence times & quality of cooking, e.g. installed location, room
temperature, etc. Therefore, the above data is only indicative.
TABLES
Overall Dimensions
60cm Models (without Feet)
820mm (H) × 600mm(W) × 600mm(D)
70cm Models (without Feet)
820mm (H) × 700mm(W) × 600mm(D)
80cm Models (without Feet)
820mm (H) × 800mm(W) × 600mm(D)
90cm Models (without Feet)
820mm (H) × 900mm(W) × 600mm(D)
Height of adjustable Feet
100mm to 160mm Approx.
BURNER SPECIFICATIONS
Type of gas:
Natural Gas – Nominal test point pressure 1.00kPa
Universal LPG – Nominal test point pressure 2.75kPa
Series 1 burner configuration
Natural Gas (Australia & New Zealand)
Burner
Qty
Main Injector
By-Pass
Nominal Gas
(mm)
Adjustment*
Consumption
(MJ/h)
Auxiliary (A)
1
0.90
Adjustable
4.0
Semi-Rapid (SR)
1
1.20
Adjustable
7.1
Rapid (R)
1 or 2
1.55
Adjustable
11.8
Fish (F)
0 or 1
1.65
Adjustable
13.0
Triple Ring Wok (W)
1
1.75
Adjustable
15.0
Oven - 60&70cm (SO)
1
1.55
3/8
11.5
Oven - 80&90cm (LO)
1
2.00
3/4
19.0
Universal LPG
Burner
Qty
Main Injector
By-Pass
Nominal Gas
(mm)
(mm)
Consumption
(MJ/h)
Auxiliary (A)
1
0.50
0.27
3.2
Semi-Rapid (SR)
1
0.70
0.29
6.4
Rapid (R)
1 or 2
0.90
0.39
10.5
Fish (F)
0 or 1
1.00
0.60
13.0
Triple Ring Wok (W)
1
1.00
0.65
13.0
Oven - 60&70cm (SO)
1
0.90
0.55
10.5
Oven (80&90cm) (LO)
1
1.20
0.54(1/4 turn open)
18.5
* By-pass jets are fully tightened for U-LPG (unless otherwise started) and adjusted from fully closed on Natural
Gas.