- 62 -
Line
Function
Setting range
or display
Setting
increment
Basic
setting
6201
S
Reset sensors
No, Yes
No
6205
S
Reset to default parameters
No, Yes
No
6220
S
Software version (RVS)
0... 99
--
6300
S
Info 1 OEM
0... 65535
--
6301
S
Info 2 OEM
0... 65535
--
LPB system
6600
S
Device address
0... 16
1
Error
6710
U
Reset Defaut relais
No, Yes
No
6711
U
Reset HP
No, Yes
No
6800
S
History 1
Time, Date, Error code
6802
S
History 2
Time, Date, Error code
6804
S
History 3
Time, Date, Error code
6806
S
History 4
Time, Date, Error code
6808
S
History 5
Time, Date, Error code
6810
S
History 6
Time, Date, Error code
6812
S
History 7
Time, Date, Error code
6814
S
History 8
Time, Date, Error code
6816
S
History 9
Time, Date, Error code
6818
S
History 10
Time, Date, Error code
Maintenance / special regime
7070
S
HP interval
--, 1... 240
1 month
--
7071
S
HP time since maint
Reset ? (no, yes)
0... 240
1 month
0
7073
S
Cur starts compr1/hrs run (since the 6 last weeks)
Reset ? (no, yes)
0... 12
0
7141
U
Emergency operation
Off, On
Off
Off: Heat pump functions normally (with boosters if necessary).
On: Heat pump uses the electric boost system or the boiler connection.
Use the “On” position only in Assist mode or Test mode: may result in high power bills.
7142
S
Emergency operating function type
Manual, Automatic
Manual
Manual: Emergency mode is not active when a fault occurs (Emergency mode = OFF).
Automatic: Emergency mode is active when a fault occurs (Emergency mode = ON).
In "Automatic" position, the energy cost can be onerous if the error is not detected and eliminated.
7150
I
Simulation outdoor temp
-50... 50 °C
0.5
--
Waterstage / Installation / 2011 - EN
Содержание Waterstage WOYK150LJL
Страница 17: ... ...
Страница 37: ... ...
Страница 39: ... 39 fig 33 Cable passages Power cables Sensor cables Waterstage Installation 2011 EN ...
Страница 67: ... ...