- (OU01 - 04) -
Outdoor unit / 3 phase
O
U
TD
O
O
R U
N
IT
WO
K1
12
-1
60
LC
O
U
TD
O
O
R U
N
IT
WO
K1
12
-1
60
LC
SPECIFICATIONS
21
NOMINAL CAPACITY AND NOMINAL INPUT
2-11
Model name (Outdoor unit)
WO
Û
K112LCT
WO
Û
K140LCT
WO
Û
K160LCT
POWER SOURCE
3Ø 400V/50Hz
+7°C/+35°C
floor heating
Heating capacity
Minimum
kW
6.20
6.20
6.20
Nominal
10.80
13.50
15.17
Maximum
19.50
21.00
22.00
Input power
Nominal
2.51
3.20
3.70
COP
-
4.30
4.22
4.10
+7°C/+45°C
radiators
Heating capacity
Nominal
kW
10.10
12.60
13.00
Input power
3.01
3.81
4.00
COP
-
3.35
3.30
3.25
+2°C/+35°C
floor heating
Heating capacity
Nominal
kW
10.77
13.00
13.50
Input power
3.40
4.15
4.34
COP
-
3.17
3.13
3.11