Floor curing function
Off
•
The function is deactivated.
Heating operational (Fh)
•
The first part of the temperature profile is
automatically completed.
Heating "ready for occupancy" (Bh)
•
The second part of the temperature profile is
handled automatically.
Heating "ready for occupancy" /
•
Heating operational
The full temperature profile (1st and 2nd part) is
performed automatically.
Manual
•
No temperature profile is performed, but the control
is performed according to the "manual controlled
drying setpoint". The function is automatically
terminated after 25 days
Important:
The standards and directions of the building
-
contractor must be followed!
This function will not work properly unless
-
the installation has been adequately made
(hydraulics, electricity, settings). Otherwise, the
floors to be dried may be damaged!
The function may be prematurely interrupted by
-
setting it to Off.
The maximum flow temperature limitation
-
remains active.
Heat pump
flow temp
X : Starting day
Days
Bh
Fh
Fh + Bh
Floor curing setpoint manually
The flow temperature setpoint for the "Manually"
controlled floor drying function can be adjusted
respectively for each heating circuit.
Floor curing day current
Displays the current flow temperature setpoint for
the controlled floor drying function.
Floor curing day completed
Displays the current day of the controlled floor
drying function.
Important:
After a power outage, the installation resumes the
controlled drying function as it was when the
outage occurred.
Operating Mode Changeover
LINE
FUNCTION
HC1
HC2
900
1200
Operating mode changeover
(None / Protection / Reduced / Comfort / Automatic)
In case of an external changeover via input H2 (on
the extension module only) the operating mode to
which the changeover will be performed must be
previously defined.
Содержание Waterstage WO*K112LCT
Страница 3: ...1 OUTDOOR UNIT DTW_3SP002E_02 CHAPTER01 2013 2 28 3 PHASE TYPE WO K112LCT WO K140LCT WO K160LCT ...
Страница 30: ...2 HYDRAULIC UNIT DTW_3SP002E_02 CHAPTER02 2013 03 22 3 PHASE TYPE WS K160DC9 ...
Страница 44: ...3 CONTROL SYSTEM DTW_1SP002E_02 CHAPTER03 2013 03 22 WS G140DC6 Hydraulic unit WS K160DC9 Hydraulic unit ...
Страница 125: ... CS01 80 Control system CS01 80 CONTROL SYSTEM CONTROL SYSTEM ...