3-22
SPARC Enterprise T2000 Server Service Manual • April 2007
■
Example showing a fault that was detected by POST. These kinds of faults are
identified by the message
deemed faulty and disabled
and by a FRU name.
■
Example showing a fault that was detected by the PSH technology. These kinds of
faults are identified by the text
Host detected fault
and by a UUID.
3.3.3
Running the
showenvironment
Command
The
showenvironment
command displays a snapshot of the server’s
environmental status. This command displays system temperatures, hard drive
status, power supply and fan status, front panel LED status, voltage and current
sensors. The output uses a format similar to the Solaris OS command
prtdiag
(1m).
●
At the
sc>
prompt, type the
showenvironment
command.
The output differs according to your system’s model and configuration.
Example:
sc>
showfaults -v
ID Time FRU Fault
1 OCT 13 12:47:27
MB/CMP0/CH0/R0/D0 MB/CMP0/CH0/R0/D0 deemed
faulty and disabled
sc>
showfaults -v
ID Time FRU Fault
0 SEP 09 11:09:26
MB/CMP0/CH0/R0/D0 Host detected fault, MSGID:
SUN4U-8000-2S UUID: 7ee0e46b-ea64-6565-e684-e996963f7b86
sc>
showenvironment
=============== Environmental Status ===============
------------------------------------------------------------------------------
--
System Temperatures (Temperatures in Celsius):
------------------------------------------------------------------------------
--
Sensor Status Temp LowHard LowSoft LowWarn HighWarn HighSoft
HighHard
------------------------------------------------------------------------------
--
PDB/T_AMB OK 23 -10 -5 0 45
50 55
MB/T_AMB OK 26 -10 -5 0 50
55 60
MB/CMP0/T_TCORE OK 44 -10 -5 0 85
Содержание SPARC Enterprise T2000
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 16: ...xiv SPARC Enterprise T2000 Server Service Manual April 2007 ...
Страница 18: ...xvi SPARC Enterprise T2000 Server Service Manual April 2007 ...
Страница 27: ...Preface xxv Reader s Comment Form ...
Страница 43: ...Chapter 3 Server Diagnostics 3 3 FIGURE 3 1 Diagnostic Flow Chart flowchart ...
Страница 69: ...Chapter 3 Server Diagnostics 3 29 FIGURE 3 10 Flowchart of ALOM CMT Variables for POST Configuration ...
Страница 106: ...4 12 SPARC Enterprise T2000 Server Service Manual April 2007 ...
Страница 152: ...5 46 SPARC Enterprise T2000 Server Service Manual April 2007 ...
Страница 163: ...Appendix A Field Replaceable Units A 3 FIGURE A 2 Field Replaceable Units 2 of 2 13 11 12 10 14 16 15 ...
Страница 173: ......
Страница 174: ......