5-12
SPARC Enterprise T2000 Server Service Manual • April 2007
5.2.3
Removing DIMMs
Note –
Not all DIMMs detected as faulty and offlined by POST must be replaced. In
service (maximum) mode, POST detects memory devices with errors that might be
corrected with Solaris PSH. See
Section 3.4.5, “Correctable Errors Detected by POST”
Caution –
This procedure requires that you handle components that are sensitive to
static discharges that can cause the component to fail. To avoid this problem, ensure
that you follow antistatic practices as described in
Electrostatic Discharge Prevention Measures” on page 5-6
1. Perform the procedures described in
Section 5.1, “Common Procedures for Parts
2. Locate the DIMMs (
) that you want to replace.
Use
and
to identify the DIMMs you want to remove.
Note –
For memory configuration information see
.
Содержание SPARC Enterprise T2000
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 16: ...xiv SPARC Enterprise T2000 Server Service Manual April 2007 ...
Страница 18: ...xvi SPARC Enterprise T2000 Server Service Manual April 2007 ...
Страница 27: ...Preface xxv Reader s Comment Form ...
Страница 43: ...Chapter 3 Server Diagnostics 3 3 FIGURE 3 1 Diagnostic Flow Chart flowchart ...
Страница 69: ...Chapter 3 Server Diagnostics 3 29 FIGURE 3 10 Flowchart of ALOM CMT Variables for POST Configuration ...
Страница 106: ...4 12 SPARC Enterprise T2000 Server Service Manual April 2007 ...
Страница 152: ...5 46 SPARC Enterprise T2000 Server Service Manual April 2007 ...
Страница 163: ...Appendix A Field Replaceable Units A 3 FIGURE A 2 Field Replaceable Units 2 of 2 13 11 12 10 14 16 15 ...
Страница 173: ......
Страница 174: ......