4. HEATING OPERATION
Switch the airflow [AUTO], and the indoor fan motor will run according to a room temperature,
as shown in Fig.6.
On the other hand, if switched in [HIGH] ~ [LOW], the indoor motor will run at a constant airflow
of [HEAT] operation modes LOW, MED, HIGH, as shown in Table5.
6. DRY OPERATION
Refer to the table 5.
During the dry mode operation, the fan speed setting can not be changed.
01-07
Indoor heat exchanger
temperature
( Fig.6 : Airflow change - over ( Heating : AUTO ) )
TR-Ts > -1.0°C
=
-2.0°C > TR-Ts
1.0°C > TR-Ts > -2.0°C
=
TR-Ts > -1.5°C
=
-2.5°C > TR-Ts
-1.5°C > TR-Ts > -2.5°C
=
LOW mode
MED mode
HIGH mode
5. COOL AIR PREVENTION CONTROL (Heating mode)
The maximum value of the indoor fan speed is set as shown in Fig.7, based on the detected
temperature by the indoor heat exchanger sensor on heating mode.
When the compressor does not operate, the indoor fan motor operates [S-Lo] mode.
( Fig.7 : Cool Air Prevention Control )
*On the Quiet mode, the Quiet mode is kept
*On the Quiet mode, the Quiet mode is kept.
.
13 min. later
SETTING
FAN MODE
Lo mode*
S-Lo
37°C
29°C
I
I
ndoor heat exchanger
t
t
emperature
SETTING
FAN MODE
Lo mode*
Lo mode*
27°C
24°C
ndoor heat exchanger
emperature