Chapter 9 Operation and Maintenance
■
CD-ROM Drive Unit / DVD-RAM Drive Unit
●
Cannot read data.
• Check to see whether the CD-ROM is inserted properly. If it is not inserted, correctly insert the CD-
ROM so that the label is facing up.
• The CD-ROM may be dirty. If it is dirty, wipe it with a soft, dry cloth.
• The CD-ROM may be scratched or bent. If scratched or damaged, replace the CD-ROM.
●
The unit does not operate properly.
Check to see whether the internal cable is connected properly. If it is not connected, correctly connect
the internal cable.
9.2.2 Error Messages
■
POST Error Messages
This section explains error messages of Power On Self Test: a device check performed during the server
startup (POST).
If an error occurs during POST, the following messages are displayed.
`
When checking/changing the settings of the BIOS Setup Utility, refer to "8.2 BIOS Setup Utility"
(
`
For instructions on checking peripheral connections, refer to "Start Guide".
`
For details on installing internal options, refer to "Chapter 7 Installing Internal Options" (
table: List of POST Errors
Message
Description
Failure Fixed Disk
IDE device error. Confirm the [Parallel ATA] setting on the
[Main] menu of the BIOS Setup Utility. If the message still
appears, the baseboard must be replaced. Contact an office
listed in the "Contact Information" of "Start Guide".
Stuck Key
Keyboard error.Check whether the keyboard is connected
properly. If the message still appears, the keyboard must be
replaced.
Keyboard error
Keyboard controller error
Keyboard controller error. Release any keys held down on the
keyboard. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of "Start Guide".
System RAM Failed at offset: ********h
Memory error. Power off the server and turn it back on. If the
message still appears, check the error log and replace the faulty
memory module.
Shadow RAM Failed at offset: ********h
Extended RAM Failed at address line: ****h
Memory type mixing detected
The installation configuration of the memory is wrong. Verify
that the same type of memory modules are installed in the slots
of the same bank. If the message displays even though the
installation is correct, replace the memory module.
Содержание primergy TX150
Страница 39: ...39 PRIMERGY TX150 S4 User s Guide 1 Overview 2 Press the floppy disk eject button The floppy disk comes out ...
Страница 112: ...112 Chapter 3 OS Installation Using ServerStart ...
Страница 140: ...140 Chapter 4 Manual OS Installation ...
Страница 174: ...174 Chapter 5 Operations after OS Installation ...
Страница 182: ...182 Chapter 6 High Reliability Tools ...
Страница 214: ...214 Chapter 7 Installing Internal Options ...
Страница 248: ...248 Chapter 8 Configuring Hardware and Utilities ...
Страница 300: ...300 D Recycling ...
Страница 304: ...304 ...