Enter the commands below, followed by [ENTER]:
1.
/etc/init.d/srvmagt stop
/etc/init.d/srvmagt_scs stop
/etc/init.d/eecd stop
/etc/init.d/eecd_mods_src stop
2.
cd /etc/srvmagt
3.
rm -f cehist.bin
4.
/etc/init.d/eecd_mods_src start
/etc/init.d/eecd start
/etc/init.d/srvmagt start
/etc/init.d/srvmagt_scs start
▶
Ensure that all pre-fail/fail status issues have been resolved in ServerView
Operations Manager.
Using Infrastructure Manager
The status of server (node) which failed CPU is installed becomes error.
When replacing the CPU, the status will be updated after getting information
manually or automatically updated daily.
Proceed as follows to get node information with Infrastructure Manager:
▶
Start up the GUI of the Infrastructure Manager and login.
▶
Display the node list from menu (
manage
>
node
).
▶
Select the target node and display the detail screen.
▶
Execute getting node information from action menu.
5.3.6.2
Resetting the error status after replacing memory modules
In case of a memory error, an error counter may be set for the defective
memory module.
Basic software procedures
RX4770 M6
Upgrade and Maintenance Manual
95
Содержание PRIMERGY RX4770 M6
Страница 80: ...Basic hardware procedures 80 Upgrade and Maintenance Manual RX4770 M6 ...
Страница 166: ...Hard disk drive HDD solid state disk SSD 166 Upgrade and Maintenance Manual RX4770 M6 ...
Страница 298: ...Liquid cooling LC 298 Upgrade and Maintenance Manual RX4770 M6 ...
Страница 314: ...Accessible drives 314 Upgrade and Maintenance Manual RX4770 M6 ...
Страница 386: ... Resuming BitLocker functionality on page 104 System board and components 386 Upgrade and Maintenance Manual RX4770 M6 ...
Страница 420: ...FUJITSU Server PRIMERGY RX4770 M6 System Cabling Overview System Cabling Overview English Cable Plan for November 2020 ...
Страница 428: ...9 RX4770 M6 Power 8x2 5 Cable Plan System Board BTM D3892 A100 C100 PWR 1 8x 2 5 HDD Backplane 1 PWR CA05950 2195 ...