Additionally, a lifter is required in the following cases:
–
The server weighs more than 50 kg.
–
The server weighs more than 21 kg and is to be removed above the height
of 25 U.
When using a lifter, this removal procedure needs to be carried out by
maintenance personnel.
Figure 6: Removing the server from the rack
▶
Press on the locking bars on both rack rails (1).
▶
Lift the server out of the rack rails (2) and place it on an even surface.
4.5.4
Removing the top covers
Tools:
Phillips PH2 / (+) No. 2 screw driver (for cover 2 and cover 3)
Basic hardware procedures
RX4770 M6
Upgrade and Maintenance Manual
51