flashing orange
Non-CSS component failure detected.
Possible causes:
– System is out of the specified temperature range
– Defective sensor
– CPU error
– Error detected by server management software
HDD/SSD activity indicator (5)
Status
Description
flashing green
Data access in progress.
iRMC-related status signals
ID indicator
Global error
indicator
Description
flashing blue
off
A remote connection has been
established. Local VGA output has been
disabled during the remote session.
flashing blue
flashing orange An emergency flash of the iRMC firmware
is in progress.
For more information about the iRMC flash procedure, see "Basic
software procedures" in the "FUJITSU Server PRIMERGY RX4770 M6
Upgrade and Maintenance Manual".
HDD prefailure detection
Depending on your hardware configuration HDD prefailure detection will be
supported.
Appendix A
406
Upgrade and Maintenance Manual
RX4770 M6
Содержание PRIMERGY RX4770 M6
Страница 80: ...Basic hardware procedures 80 Upgrade and Maintenance Manual RX4770 M6 ...
Страница 166: ...Hard disk drive HDD solid state disk SSD 166 Upgrade and Maintenance Manual RX4770 M6 ...
Страница 298: ...Liquid cooling LC 298 Upgrade and Maintenance Manual RX4770 M6 ...
Страница 314: ...Accessible drives 314 Upgrade and Maintenance Manual RX4770 M6 ...
Страница 386: ... Resuming BitLocker functionality on page 104 System board and components 386 Upgrade and Maintenance Manual RX4770 M6 ...
Страница 420: ...FUJITSU Server PRIMERGY RX4770 M6 System Cabling Overview System Cabling Overview English Cable Plan for November 2020 ...
Страница 428: ...9 RX4770 M6 Power 8x2 5 Cable Plan System Board BTM D3892 A100 C100 PWR 1 8x 2 5 HDD Backplane 1 PWR CA05950 2195 ...