38
Operating Manual
RX220
Installing/Removing the Server into/from the Rack
Hardware Installation
The server is removed in the reverse order.
V
CAUTION!
No cable management is available for the server!
Before the server is removed, all cables must be disconnected from their
sockets. Please note the instructions in
section “Installing/Removing the
Server into/from the Rack” on page 29
.
4.3.7
Mounting in 3rd-Party Racks
For mounting the server in the 3rd-Party Rack the following parts are necessary:
–
one left and one right telescopic rail (assembled)
–
possibly ten plugwashers
Ê
Take the original manual of the rack manufacturer regarding the mechanical
installation and/or the climatic conditions to assistance.
V
CAUTION!
With the installation in 3rd-Party Rack it is to be made certain that the
air flow is ensured from the front to the rear in the rack.
Ê
Mount the necessary manufacturer original parts (like support bracket).
I
Sometimes a number of parts of the delivered mounting kit cannot be
used because original parts of the 3rd-Party Rack are to be used.
Ê
Mount the telescopic bars as described in
section “Preparing the Server” on
page 33
.
Ê
Secure the telescopic rails into the rack as described in
section “Mounting in
the PRIMECENTER/DataCenter Rack” on page 34
.
Ê
Mount the server (see
“Installing the Server” on page 37
) and route the
cables as described in the original manual of the rack.