102
Upgrade and Maintenance Manual
CX400
S1
Hard disk drives / solid state drives
7.2.1.1
Configuration with standard CPU
Figure 63: Configuration with standard CPU
7.2.1.2
Configuration with 135 W (8 core) or 130 W (4 core) CPU support
Figure 64: Configuration with135 W (8 core) or 130 W (4 core) CPU support
W ithout E xpander
HDD slot#
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
6G
6G
3G
3G
3G
3G
6G
6G
3G
3G
3G
3G
6G
6G
3G
3G
3G
3G
6G
6G
3G
3G
3G
3G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
1U
onb non-RAID
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
1U
onb SW RAID
1
0
2
1
3
2
4
3
1
0
2
1
3
2
4
3
1
0
2
1
3
2
4
3
1
0
2
1
3
2
4
3
1U
HW RAID
5
6
1
0
2
1
3
6
4
7
5
0
6
1
1
4
2
5
3
6
4
7
5
0
6
1
1
4
2
5
3
6
4
7
5
0
6
1
1
4
2
5
3
6
4
7
2U
onb non-RAID
5
6
1
2
3
4
5
6
1
2
3
4
2U
onb SW RAID
1
0
2
1
3
2
4
3
1
0
2
1
3
2
4
3
2U
HW RAID
5
4
6
5
1
0
2
1
3
2
4
3
5
4
6
5
1
0
2
1
3
2
4
3
W ith E xpander
2U
HW RAID
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
2U
HW RAID
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
not supported
"1, 2, 3…6" means HDD mounting order
Tray2
Tray4
Tray2
Tray2
Tray4
Tray1
Tray2
Tray3
Tray4
Onboard
HW RAID
SCU
AHCI
SCU
LSI 2108
LSI 2108
LSI 2108
LSI 2108
AHCI
SCU
AHCI
SCU
AHCI
red numbers:
disk slot numbering, will be shown on RAID Manager software etc.
1
0
4
5
W ithout E xpander
HDD slot#
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
6G
6G
3G
3G
3G
3G
6G
6G
3G
3G
3G
3G
6G
6G
3G
3G
3G
3G
6G
6G
3G
3G
3G
3G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
6G
1U
onb non-RAID
(3)
(4)
1
2
1
2
(3)
(4)
(3)
(4)
1
2
1
2
(3)
(4)
1U
onb SW RAID
1
0
2
1
1
0
2
1
1
0
2
1
1
0
2
1
1U
HW RAID
(3)
(4)
1
0
2
1
1
0
2
1
(3)
(4)
(3)
(4)
1
0
2
1
1
0
2
1
(3)
(4)
2U
onb non-RAID
1
2
(3)
(4)
1
2
(3)
(4)
2U
onb SW RAID
1
0
2
1
1
0
2
1
2U
HW RAID
1
0
2
1
(3)
(4)
1
0
2
1
(3)
(4)
not supported
(3)
(4) special release only
(3)
(4) technically, OK. But BTO assembly possible for Augsburg factory only
"1, 2, 3…6" means HDD mounting order
Tray1
Tray2
Tray3
Tray4
Tray2
Tray4
SCU
AHCI
SCU
HW RAID
LSI 2108
LSI 2108
LSI 2108
LSI 2108
Onboard
AHCI
SCU
AHCI
SCU
AHCI
red numbers:
disk slot numbering, will be shown on RAID Manager software etc.
1
0
Содержание PRIMERGY CX400 S1
Страница 12: ...12 Bearbeitungsstand Bestellnummer Content ...
Страница 14: ...14 Upgrade and Maintenance Manual CX400 S1 Version history ...
Страница 18: ...18 Upgrade and Maintenance Manual CX400 S1 Introduction ...
Страница 76: ...76 Upgrade and Maintenance Manual CX400 S1 Basic hardware procedures ...
Страница 132: ...132 Upgrade and Maintenance Manual CX400 S1 Hard disk drives solid state drives ...
Страница 194: ...194 Upgrade and Maintenance Manual CX400 S1 Cabling Figure 145 Midplane 1 MB1 2 MB2 3 J14 4 J16 5 MB4 6 MB3 7 J15 8 J13 ...
Страница 196: ...196 Upgrade and Maintenance Manual CX400 S1 Cabling 12 3 Cabling Figure 147 2 5 inch chassis ...
Страница 197: ...CX400 S1 Upgrade and Maintenance Manual 197 Cabling Figure 148 3 5 inch chassis ...
Страница 198: ...198 Upgrade and Maintenance Manual CX400 S1 Cabling ...