Upgrade and Maintenance Manual
CX2550/60/70 M4
Basic hardware procedures
Ê
When using ServerView Operations Manager to toggle the ID indicator,
choose
Single System View
and press the
Locate
button.
Ê
Remember to switch off the ID indicator after the maintenance task has been
concluded successfully.
4.1.2
Determining the error class
The Local Service Concept (LSC) allows you to identify defective server
components. Failure events are assigned to one of two error classes:
–
Customer Self Service
(CSS) error events that may be resolved by
operating personnel
–
Global Error
events that need to be resolved by maintenance personnel
Global Error and CSS LEDs (see section
"Controls and indicators on the server
) indicate, if the defective component is a customer
replaceable unit or if maintenance personnel needs to be dispatched to replace
the part.
I
The indicators also light up in standby mode and after a server restart
due to a power failure.
4.1.2.1
Customer Self Service (CSS) indicator
Ê
Check the CSS indicator on the front panel of the server enclosure or I/O
panel on the server (see section
"Controls and indicators on the server
Ê
For further diagnostics, proceed as follows:
– Hardware errors:
Check the System Event Log (SEL), see "Upgrade and Maintenance
Manual" of the related server node.
– Software/agent related errors:
Check the ServerView System Monitor, available on Windows or Linux
based servers with ServerView agents installed.
I
For further information, see "ServerView System Monitor" user
guide.
Содержание PRIMERGY CX2550 M4
Страница 6: ...6 Upgrade and Maintenance Manual CX2550 60 70 M4 ...
Страница 20: ...Upgrade and Maintenance Manual CX2550 60 70 M4 Contents ...
Страница 46: ...46 Upgrade and Maintenance Manual CX2550 60 70 M4 Important information ...
Страница 70: ...70 Upgrade and Maintenance Manual CX2550 60 70 M4 Basic hardware procedures ...
Страница 114: ...114 Upgrade and Maintenance Manual CX2550 60 70 M4 Expansion cards and OCP mezzanine cards ...
Страница 182: ...182 Upgrade and Maintenance Manual CX2550 60 70 M4 Expansion cards and OCP mezzanine cards ...
Страница 192: ...192 Upgrade and Maintenance Manual CX2550 60 70 M4 Main memory Figure 85 Memory dummy module ...
Страница 204: ...204 Upgrade and Maintenance Manual CX2550 60 70 M4 Main memory ...
Страница 320: ...320 Upgrade and Maintenance Manual CX2550 60 70 M4 System board and components ...
Страница 356: ...356 Upgrade and Maintenance Manual CX2550 60 70 M4 GPGPU extension tray ...
Страница 418: ...418 Upgrade and Maintenance Manual CX2550 60 70 M4 SXM2 extension tray ...
Страница 454: ...454 Upgrade and Maintenance Manual CX2550 60 70 M4 Appendix ...