CX2550/60/70 M4
Upgrade and Maintenance Manual
449
Appendix
13.2.2.2 Indicators on the server node
Global Error indicator (orange)
–
Lights up orange
if a prefailure event has been detected that
requires (precautionary) service intervention.
–
Flashes orange
if an error was detected that requires service
intervention.
–
Does not light up
if there is no critical event.
If the event is still acute after a power cycle, the indicator is
activated after the restart.
The indicator also lights up in standby mode.
You can find more details on the indicated errors in the System
Event Log (SEL), in the ServerView Operations Manager or via
the iRMC S4's Web interface.
ID
ID indicator (blue)
Lights up blue when the system has been selected by pressing
the ID button. To deactivate, press the button again.
The ID indicator can also be activated via the ServerView
Operations Manager and the iRMC S4 Web interface and its
status reported to the ServerView Operations Manager and the
iRMC S4.
CSS indicator (orange)
–
Lights up orange
if a prefailure event was detected for a CSS
component that you can fix yourself (for reasons of precaution)
with the CSS concept.
–
Flashes orange
if an error was detected that you can fix
yourself with the CSS concept.
–
Does not light up
when the supervised components are OK.
If the event is still acute after a power cycle, the indicator is
activated after the restart.
The indicator also lights up in standby mode.
!
Содержание PRIMERGY CX2550 M4
Страница 6: ...6 Upgrade and Maintenance Manual CX2550 60 70 M4 ...
Страница 20: ...Upgrade and Maintenance Manual CX2550 60 70 M4 Contents ...
Страница 46: ...46 Upgrade and Maintenance Manual CX2550 60 70 M4 Important information ...
Страница 70: ...70 Upgrade and Maintenance Manual CX2550 60 70 M4 Basic hardware procedures ...
Страница 114: ...114 Upgrade and Maintenance Manual CX2550 60 70 M4 Expansion cards and OCP mezzanine cards ...
Страница 182: ...182 Upgrade and Maintenance Manual CX2550 60 70 M4 Expansion cards and OCP mezzanine cards ...
Страница 192: ...192 Upgrade and Maintenance Manual CX2550 60 70 M4 Main memory Figure 85 Memory dummy module ...
Страница 204: ...204 Upgrade and Maintenance Manual CX2550 60 70 M4 Main memory ...
Страница 320: ...320 Upgrade and Maintenance Manual CX2550 60 70 M4 System board and components ...
Страница 356: ...356 Upgrade and Maintenance Manual CX2550 60 70 M4 GPGPU extension tray ...
Страница 418: ...418 Upgrade and Maintenance Manual CX2550 60 70 M4 SXM2 extension tray ...
Страница 454: ...454 Upgrade and Maintenance Manual CX2550 60 70 M4 Appendix ...