49
PRIMERGY BX600 S3 Blade Server System Unit Hardware Guide
4
Install a SFP module to a port to use.
1. Remove the cap from the port using FC Network Blade.
2. Check the SFP module direction and insert it into the port while keeping the lever
raised, until you hear it click.
Connect it to the port whose number is the same as that of the Server Blade slot to be
connected via Fibre Channel (The figure shows an example using FC Pass-Thru Blade).
SFP module is sold separate.
The SFP module is necessary for the number of external ports to use.
5
Connect the Fibre Channel cable to the SFP module.
1. Remove the cap of the SFP module.
2. Insert the cable firmly into the SFP module till the latch clicks.
Set the cable connector key (protrusion on one side of the cable connector) to fit the slot of
the SFP module, and insert the cable.
3. As for the rest of the SFP module, repeat in the same way.
Be sure to install with the lever raised. If the lever is raised after inserting the SFP
module with the lever down, the lock is unlocked and the SFP module becomes loose.
Check that the Fibre Channel cable connector is inserted firmly to the back of the slot.
SFP module
[Port number]
1
3
5
7
9
2
4
6
8
10
Lever