4.9 Dump Environment Setup (Linux: Red Hat)

4.9.3.2

Setting a label for the dump saving area

Use the e2label command to set a label for the area to which a dump is to be saved.

4.9.3.3

Setting up the dump environment

Edit /etc/kdump.conf to specify the area to which a dump is to be saved.  Also, make 

settings for the dump function and others.  The setting procedure is explained using a 

definition example below.  Code the parts, which are not explained, as indicated in the 

definition example.

1

Set /dump and the label for the area to which the dump is to be collected, and 
define the label as the dump saving area.

2

Specify reboot for the operation to be performed after dump collection.  If 

sadump has been applied, the sadump definition is followed after kdump 

collection, and therefore the values set here are ignored.

3

Specify this to use the compressed dump function.  Omit it if the function is not 

used.  The compressed dump function can reduce the dump collection area but 

may take more time for dump collection.  Perform performance verification 

sufficiently before enabling the compressed dump function.

4

Specify this to use the partial dump function.  Omit it if the function is not used.  

Also, add the following definition to KDUMP_COMMANDLINE_APPEND of  

 

/etc/sysconfig/kdump.

If /etc/kdump.conf is set again, the sadump service or system needs to be restarted.

# e2label /dev/sdb2 /dump                 

Set

# e2label /dev/sdb2                       

Verify

/dump

ext3 LABEL=/dump

           ~~~~~(1)

path /

core_collector makedumpfile

default reboot

~~~~~~~~~~~~~~(2)

core_collector makedumpfile -c -d 3

                            ~(3)~~~~(4)

swiotlb=128

Содержание PRIMEQUEST 400 Series

Страница 1: ...C122 E001 10EN Front Cover INSTALLATION MANUAL ...

Страница 2: ......

Страница 3: ...as office work personal device household appliance and general industrial applications This product is not intended for use in nuclear reactor control systems aeronautical and space systems air traffic control systems mass transportation control systems medical devices for life support missile launch control systems or other specialized uses in which extremely high levels of reliability are requir...

Страница 4: ...re designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause ha...

Страница 5: ... noted with trademark or registered trademark symbols TERMS AND CONDITIONS The product includes software provided by third parties in addition to that provided by Fujitsu Ltd You are granted permission to use the third parties software subject to the terms and conditions below If you acquire the source code of the software to which the following terms and conditions apply refer to LICENSE1_EN pdf ...

Страница 6: ...1 10EN The contents of this manual shall not be disclosed in any way or reproduced in any media without the express written permission of Fujitsu Limited All Rights Reserved Copyright FUJITSU LIMITED 2005 2008 ...

Страница 7: ...E correction Addition of notes for network settings Correction of the procedures for Linux installation Addition of notes for PSA installation 06 2006 08 11 All chapters correction CHAPTER 2 correction APPENDIX A correction APPENDIX D correction Addition of description for PRIMEQUEST 500 series Addition of description for SUSE Addition of description and notes for XPAR setting Addition of descript...

Страница 8: ...ption for Linux dump function kdump 09 2008 03 10 Entire manual addition Addition of description for PRIMEQUEST 580A 540A 520A 10 2008 04 10 Entire manual correction Technical brushup Note In this table the revised section is indicated by its section number in the current edition An asterisk indicates a section in the previous edition ...

Страница 9: ...ack Structure and Contents of this Manual This manual is organized as described below CHAPTER 1 PRIMEQUEST Overview Provides an overview of the hardware software and network connections and describes the workflow leading up to the initiation of operation CHAPTER 2 Setup Describes how to perform the setup procedures required after installing the main unit CHAPTER 3 Operating System Installation Des...

Страница 10: ...wer Control Describes power on and power off Appendix D Installation in the SAN Boot Environment Describes how to set up the SAN boot environment Appendix E Setting Item List Provides lists of default values for the MMB server management unit and PSA PRIMEQUEST Server Agent Appendix F Overall View of Management LAN IP Addresses Describes the IP addresses used for PRIMEQUEST Glossary Explains the t...

Страница 11: ...22 E001EN PRIMEQUEST 580A 540A 520A 500 400 Series Reference Manual Basic Operation GUI Commands Explains operations setup methods and the system management method that are required for the system operation of the PRIMEQUEST The explanation covers basic operations and functions of the MMB PSA and EFI C122 E003EN PRIMEQUEST 500A 500 400 Series Reference Manual Tools Operation Information Explains s...

Страница 12: ... 10 for Itanium Processor Family SUSE Linux Enterprise Server 9 for Itanium Processor Family SUSE9 SUSE Linux Enterprise Server 10 for Itanium Processor Family SUSE10 Microsoft Windows XP Professional Windows XP Microsoft Windows XP Home Edition Microsoft Windows Server 2003 Enterprise Edition for Itanium based Systems Windows Windows Server 2003 Microsoft Windows Server 2003 Datacenter Edition fo...

Страница 13: ...ux Enterprise Server 10 for Itanium Processor Family z The IO Unit is indicated as IOU in the MMB Web UI and in the figures shown in this manual Conventions for Alert Messages This manual uses the following conventions to show alert messages An alert message consists of an alert signal and alert statements The command syntax is shown in a frame such as this one This indicates a hazardous situation...

Страница 14: ...tion of all components and initial settings z Removal of front rear or side covers z Mounting de mounting of optional internal devices z Plugging or unplugging of external interface cards z Maintenance and inspections repairing and regular diagnosis and maintenance In this manual it is assumed that two BMMs optional products can be connected to a single IO Unit and IOX this is reflected both in th...

Страница 15: ...eb UI z Microsoft IE Internet Explorer v5 5 SP2 or later z Netscape v7 02 or later P 2 9 Data destruction When power to the main processing unit is turned off in an operation from the MMB only the following LEDs of the OPL and the MMB stay lit z MMB Ready LED of the OPL z Power LED of the MMB z Ready LED of the MMB z Active LED of the MMB Before turning off the main power UPS power distribution bo...

Страница 16: ...mber of times after which a specified action Stop rebooting and Power Off Stop rebooting or Diagnostic Interrupt assert is performed The retry count for restarting the operating system and the action to be performed are determined according to the settings of the ASR Automatic Server Restart Control window of the MMB At this time by clicking the Apply button after checking the Cancel Boot Watchdog...

Страница 17: ...ix NOTE ON SAFETY Alert Labels The following labels are attached to this product These labels provide information to the users of this product PRIMEQUEST 580A 540A 580 540 480 440 Main unit Do not peel off the labels ...

Страница 18: ...x C122 E001 10EN NOTE ON SAFETY Extended Power Cabinet ...

Страница 19: ...C122 E001 10EN xi NOTE ON SAFETY Extended I O Cabinet ...

Страница 20: ...xii C122 E001 10EN NOTE ON SAFETY PCI_Box ...

Страница 21: ...C122 E001 10EN xiii NOTE ON SAFETY PRIMEQUEST 520A 520 420 Main unit ...

Страница 22: ......

Страница 23: ...Plugging or unplugging of external interface cards z Maintenance and inspections repairing and regular diagnosis and maintenance The following tasks regarding this product and the optional products provided from Fujitsu should only be performed by a certified service engineer Users must not perform these tasks Incorrect operation of these tasks may cause malfunction z Unpacking optional adapters a...

Страница 24: ......

Страница 25: ...rkflow for starting operation 1 1 1 2 Setup Workflow 1 1 1 2 1 Items required for setup 1 3 CHAPTER 2 Setup 2 1 2 1 Before Starting Setup 2 1 2 2 MMB Connection and Setup 2 3 2 2 1 Connection environment settings for actual operation 2 3 2 2 1 1 Specifying the IP address for the PC to be used as the MMB console 2 4 2 2 1 2 Connecting the MMB console PC to the MMB user port 2 4 2 2 1 3 External LAN...

Страница 26: ...setting flow 2 43 2 5 2 Shutting down a partition 2 45 2 5 3 Splitting and merging SBs IO Units and IOXs in the PRIMEQUEST 500A 500 series only 2 47 2 5 3 1 Splitting an SB and merging SBs 2 47 2 5 3 2 Splitting an IO Unit or IOX and merging IO Units or IOXs 2 49 2 5 4 Configuring a partition 2 51 2 5 4 1 Adding an SB IO Unit and IOX 2 51 2 5 4 2 Removing an SB IO Unit or IOX 2 55 2 5 5 Setting a ...

Страница 27: ...1 Hardware requirements and procedure 3 17 3 2 3 2 Connecting the devices 3 19 3 2 3 3 Installing the Linux OS 3 21 3 2 3 4 Installing bundled software package 3 22 3 2 3 5 Work required after installation 3 22 3 3 Windows Installation 3 23 3 3 1 Preparing for installation 3 24 3 3 1 1 Setting up a SAN boot environment 3 24 3 3 1 2 Connecting a SAN storage unit 3 25 3 3 1 3 Pre installation notes ...

Страница 28: ...0 4 3 4 2 1 Checking the management LAN settings 4 4 4 2 2 Checking the SELinux function settings 4 12 4 2 3 Checking the firewall function releasing ports 4 13 4 2 4 Installing FJSVfefpcl 4 14 4 2 5 Setting the destination of trap sending from the partition 4 14 4 2 6 Setting the destinations of trap and e mail sending via the MMB 4 17 4 2 7 Other settings 4 18 4 2 8 PSA update installation 4 20 ...

Страница 29: ...ending via the MMB 4 76 4 5 4 Windows firewall setting 4 77 4 5 5 Setting Watchdog monitoring after a STOP error a fatal system error occurs 4 79 4 5 6 PSA update installation 4 80 4 5 7 PSA uninstallation 4 84 4 6 PSA Installation Windows Server 2003 PRIMEQUEST 520A 520 420 4 85 4 6 1 Checking the management LAN settings 4 88 4 6 2 Setting the destination of trap sending from the partition 4 89 4...

Страница 30: ...Client Setup 4 132 4 11 1 NTP operation on PRIMEQUEST 4 132 4 11 2 NTP server setup 4 134 4 11 3 Setting each partition as an NTP client 4 136 4 11 3 1 NTP client operation in a partition running Linux 4 136 4 11 3 2 Setting NTP in a Windows partition 4 137 4 11 3 3 NTP setting for a domain belonging to a partition 4 139 4 12 OS Backup Settings 4 140 4 12 1 Linux Red Hat backup 4 140 4 12 1 1 Back...

Страница 31: ...dure B 1 B 1 Connecting a General purpose PC B 1 B 2 Initializing the MMB B 4 B 3 Logging in to the Web UI B 5 Appendix C Power Control C 1 C 1 Power On Off Procedures for the Main Unit C 1 C 1 1 Powering on and off by controlling the main power C 1 C 1 1 1 Power on procedure using circuit breakers PRIMEQUEST 580A 540A 580 540 480 440 C 2 C 1 1 2 Power on procedure PRIMEQUEST 520A 520 420 C 5 C 1 ...

Страница 32: ...4 2 Making settings for logical units D 5 D 4 3 Setting up the FC switch D 6 D 4 4 Configuring the EFI driver D 7 D 4 4 1 Configuring the EFI driver 3 10a6 version D 7 D 4 4 2 Configuring the EFI driver 3 11a4 version 3 11x1 version D 12 D 4 5 Notes on replacing an FC card D 17 D 5 Operating System Installation D 18 Appendix E Setting Item List E 1 E 1 Setting Items for MMB E 1 E 2 Setting Items f...

Страница 33: ...e 2 12 Alarm E Mail window 2 23 Figure 2 13 Alarm E Mail Filtering Condition window PRIMEQUEST 580A 540A 580 540 480 440 2 24 Figure 2 14 Alarm E Mail Filtering Condition window PRIMEQUEST 520A 520 420 2 24 Figure 2 15 User List window 2 27 Figure 2 16 Add User window 2 28 Figure 2 17 System Information window 2 30 Figure 2 18 Date Time window 2 32 Figure 2 19 Management LAN Port Configuration win...

Страница 34: ...on window PRIMEQUEST 480 440 2 61 Figure 2 39 Reserved SB Configuration windows PRIMEQUEST 520A and PRIMEQUEST 520 This window is displayed for an MMB firmware version 3 24 or later 2 62 Figure 2 40 Reserved SB Configuration window PRIMEQUEST 520 This window is displayed for an MMB firmware version earlier than 3 23 2 62 Figure 2 41 Reserved SB Configuration window PRIMEQUEST 420 2 62 Figure 2 42 ...

Страница 35: ...le of connections for installation using the KVM 3 37 Figure 3 19 USB Video DVD Switch window 3 37 Figure 3 20 Power Control window 3 38 Figure 3 21 Tera Term startup window 3 44 Figure 3 22 Setup window 3 45 Figure 3 23 Software license agreement window 3 45 Figure 3 24 Product key input window 3 46 Figure 3 25 OS restart window 3 46 Figure 3 26 Example of connections for installation using the i...

Страница 36: ...team mode 4 72 Figure 4 20 Selection Completed window 4 73 Figure 4 21 Team Number 0 Properties window 4 73 Figure 4 22 Local Area Connection Properties dialog box 4 74 Figure 4 23 Advanced tab 4 75 Figure 4 24 Add a Port dialog box 4 77 Figure 4 25 Add a Port dialog box 4 78 Figure 4 26 Installation preparation window 4 80 Figure 4 27 Update installation window 4 80 Figure 4 28 Update completion ...

Страница 37: ... box in time synchronization with an NTP server 4 139 Figure 4 62 Export List window example 4 150 Figure 4 63 Export window example 4 151 Figure 4 64 Backup EFI Configuration window example 4 152 Figure 5 1 Access Control window example 5 2 Figure 5 2 Edit Filter window example 5 3 Figure 5 3 Network Protocols window example 5 5 Figure 5 4 SNMP Community window example 5 7 Figure 5 5 SNMP Trap wi...

Страница 38: ...9 Power Control window C 18 Figure D 1 SAN boot configuration example 1 2 path configuration D 3 Figure D 2 SAN boot configuration example 2 4 path configuration D 3 Figure F 1 Management LAN network configuration and IP addresses PRIMEQUEST 580A 540A 580 540 480 440 F 1 Figure F 2 Management LAN network configuration and IP addresses PRIMEQUEST 520A 520 420 F 3 ...

Страница 39: ...on enabled ports in VLAN Mode of management LAN 2 36 Table 2 16 Communication enabled ports in Port Disable Mode of management LAN 2 36 Table 2 17 Displayed and setting items in the Management LAN Port Configuration window 2 38 Table 2 18 Displayed and setting items in the Mirror License window 2 39 Table 2 19 Displayed and setting items in the XPAR License window 2 41 Table 2 20 Displayed and set...

Страница 40: ...w 4 104 Table 4 6 Devices usable as dump devices 4 111 Table 4 7 Modes and sizes of memory dump 4 124 Table 4 8 Displayed and setting items in the Export window 4 150 Table 5 1 Displayed and setting items in the Access Control window 5 2 Table 5 2 Displayed and setting items in the Edit Filter window 5 4 Table 5 3 Displayed and setting items in the Network Protocols window 5 6 Table 5 4 Displayed ...

Страница 41: ...C122 E001 10EN xxxiii Contents Table C 3 Displayed and setting items in the Power Control window C 15 Table E 1 List of setting items for MMB E 1 Table E 2 List of setting items for PSA E 14 ...

Страница 42: ......

Страница 43: ...EQUEST 580A 540A 580 540 480 440 See the PRIMEQUEST 580A 540A 580 540 480 440 System Design Guide C122 B001EN z PRIMEQUEST 520A 520 420 See the PRIMEQUEST 520A 520 420 System Design Guide C122 B009EN 1 2 Setup Workflow This chapter describes how to set up the PRIMEQUEST Some setup tasks should be performed by a certified service engineer whereas other setup tasks should be performed by the user Th...

Страница 44: ...tion 2 5 z Set up the mode when necessary See Section 2 5 8 z Save the specified setting values for MMB and GSWB See Section 2 6 z GSWB is supported only in PRIMEQUEST 580A 540A 580 540 480 440 GSWB initialization MMB connection and setup operating environment Network setup for normal operation MMB initialization Partition initialization Mode settings z Install the operating systems See Chapter 3 ...

Страница 45: ...e the following items If you need to prepare these items contact the sales personnel or a certified service engineer Note An external switching hub is required to construct a system in a configuration where the PRIMEQUEST is connected to an external switching hub via a LAN z PC to be used as a console z LAN cables for user LAN ...

Страница 46: ......

Страница 47: ...ting MMB setup you need to determine the following IP address host name subnet mask and gateway address IP address of the PC to be used for the MMB console User accounts Name of the PRIMEQUEST system also used as the SNMP system name Environment used for management VLAN and others 2 Partition setup see Section 2 5 for the procedure If you use the partition function to configure multiple partitions...

Страница 48: ...s referred to here mean functions that do not use a GSWB VLAN The PRIMEQUEST GSWB User s Manual C122 E028EN explains the settings to be made during installation These settings are not required unless you plan to use GSWB To make these settings you must determine the following in advance Host name host IP address subnet mask default gateway Port to be enabled Remarks These settings are required for...

Страница 49: ...ent settings for actual operation The connection environment for testing must be reset for actual operation You need to perform the following operations z Specifying the IP address for the PC to be used as the MMB console 2 2 1 1 z Connecting the MMB console PC to the MMB user port 2 2 1 2 z External LAN connection for PRIMEQUEST PRIMEQUEST 580A 540A 580 540 480 440 2 2 1 3 Connection environment ...

Страница 50: ...MB console PC to the MMB user port by using a LAN cable After connection is complete the MMB console PC becomes able to communicate with the MMB LAN The PRIMEQUEST 580A 540A 580 540 480 440 uses a redundant MMB configuration in which one MMB is active and the other is a standby When connecting the cable to an MMB LAN port during the setup select the port of the active MMB ACT LED normally MMB 0 is...

Страница 51: ...ess 192 168 1 102 in the above figure The virtual IP address is used for communication with the externally connected targets Web browser maintenance terminal REMCS and others BMM 1 BMM 1 IOU 0 BMM 0 BMM 0 IOU 7 MMB 1 REMCS center Dial up router or external switch REMOTE REMOTE External switch Maintenance terminal FST IP 192 168 1 201 IP 192 168 1 100 IP 192 168 1 101 IP 192 168 1 200 IP 192 168 3 ...

Страница 52: ...ddresses of MMB 0 and MMB 1 can pass through The destination server is an external server outside the firewall IP addresses are restricted by the mail server used Also if the REMOTE MAINTENANCE port is used with the PRIMEQUEST 580A 540A under the above conditions the servers must be configured such that the packets with the IP addresses for REMOTE MAINTENANCE can pass through Remarks z The physica...

Страница 53: ...unction such as the spanning tree protocol and domain separation as an external switch suppress the loop guard function by disabling Spanning Tree Protocol for the port for connection between the switching hub and the main unit or by turning on Domain Separation BMM 1 BMM 1 IOU BMM 0 BMM 0 IOX REMCS center Dial up router or external switch REMOTE REMOTE External switch Maintenance terminal FST IP ...

Страница 54: ...also used for linkage with PRIMECLUSTER z If REMCS connection is involved the connection method explained below is used For details see Chapter 6 REMCS in the PRIMEQUEST 580A 540A 520A 500 400 Series Reference Manual Basic Operation GUI Commands C122 E003EN Internet connection The REMCS ports are connected to an external switching hub or to the center via the firewall from the external switch of t...

Страница 55: ...g 2 Enter the following URL nodename Specifies an MMB FQDN or IP address adminport Specifies a port number that is allocated to the MMB management port default value 8081 for standard or 432 for SSL 3 Enter a user account name and password as follows and click the Login button Remarks When the browser is started for the first time or a setting change is not made the following default user account ...

Страница 56: ...0A 540A 580 540 480 440 as an example Information displayed on the window Figure 2 4 Web UI Frame Information Window a FUJITSU logo display The FUJITSU logo mark is displayed Click this mark to display the FUJITSU homepage b Information area This area displays the following information z Model Displays the PRIMEQUEST model name Product Info Product Name of operation panel FRU a FUJITSU logo displa...

Страница 57: ...ystem status display c Active MMB display Displays the number of the MMB that is operating as an active MMB with the Web UI connected d Maintenance status display When a certified service engineer is maintaining this device by using a maintenance wizard menu Under Maintenance is displayed in orange When maintenance is not being conducted no information is displayed e Navigation bar The top layer m...

Страница 58: ...here to display the content window of that menu g Sub menu The sub menu of the menu selected on the navigation bar is displayed Figure 2 5 Sub menu Example System System Status The sub menu is displayed as follows Up to three menu hierarchies are displayed A display at the beginning indicates that there are lower layer menus A display at the beginning indicates that there are lower layer menus whi...

Страница 59: ... area The Refresh button is not displayed on all windows It is not displayed on one where only settings are made and its status is not automatically changed Remarks Use Refresh Rate in the Network Configuration menu to set a refresh rate Windows with a Refresh button display are subject to automatic refreshing Excluding PSA This area is not scrolled together with Status display and setting area z ...

Страница 60: ...area 2 Select a menu from the sub menu The window of the selected menu is displayed in the content area 3 Check and set information on the displayed window Click the Apply button to set the information Click the Cancel button to return the information to its state before it was input Remarks To return to the upper hierarchy click the Back button on the IE toolbar The upper hierarchy screen is disp...

Страница 61: ...annel Partition z Describing one of multiple components The actual Web UI is indicated with a number Component name x Example Describing a partition number in the second hierarchy Click Partition Partition x Mode If one of the MMB error or warning states shown in the following operation interruption check conditions occurs refrain from operating the window Instead contact your Fujitsu certified se...

Страница 62: ...is information may have already been set by a Fujitsu certified service engineer If the information need not be changed proceed with the next setting Notes z Specify the same subnet for the physical and virtual IP addresses of MMB 0 and MMB 1 z When the virtual IP address is set and the PRIMEQUEST series machine is accessed from an external device for example from a Web browser maintenance termina...

Страница 63: ...rtual IP Address items The host name must be specified Table 2 3 Displayed and setting items in the Network Interface window 3 In MMB 0 IP Address or MMB 1 IP Address click Enable for the Interface item and enter values for each item Specify the physical IP address to be assigned Item Description Hostname Specify the host name IP Address Specify the virtual IP address to be used to access the Web ...

Страница 64: ...EQUEST 520A 520 420 Specify information including the IP address used to access the Web UI Note that this information may have already been set by a Fujitsu certified service engineer If the information need not be changed proceed with the next setting Remarks When the IP address is changed the connection to the MMB Web UI is terminated To use the MMB Web UI log in again Procedure 1 Click Network ...

Страница 65: ...tton Note If an incorrect value is specified for the IP address or another required parameter the MMB Web UI is not displayed Connect a general purpose PC to the COM port of the MMB and specify the correct values For details on how to set the parameters see Appendix B Installation Procedure Item Description Hostname Specify the host name IP Address Specify the IP address to be used to access the W...

Страница 66: ...rotocols window 2 Specify the settings to the Telnet items Table 2 6 Displayed and setting items in the Network Protocols window 3 Click the Apply button Item Description Telnet Telnet Sets Enable Disable of Telnet Default Disable Telnet Port Sets a port to be used for Telnet Default 23 Timeout Sets a time interval allotted for entering data with Telnet connected before the connection is cut off A...

Страница 67: ...g up the DNS server Specify the DNS server to enable its use You may specify it at a later time Procedure 1 Click Network Configuration Network Interface The Network Interface window appears Figure 2 10 Network Interface window PRIMEQUEST 580A 540A 580 540 480 440 ...

Страница 68: ...et up MMB SMTP Simple Mail Transfer Protocol More specifically specify whether to report errors by e mail if they occur during operation If you specify reporting by e mail you will also need to specify the error level and the report destinations Item Description DNS Specify whether to use the DNS server Enabled Use the DNS server Disabled Do not use the DNS server The default is Disabled DNS Serve...

Страница 69: ...ck the Apply button To send e mail for testing Click the Test E Mail button Note A DNS server must be specified prior to specifying a fully qualified domain name FQDN You can specify it by selecting Network Configuration Network Interface Item Description Alarm E Mail Specifies whether to transmit an Alarm E Mail if an event occurs To specify transmission select Enable From Sets the E Mail address...

Страница 70: ...mail sending conditions click the Filter button in the Alarm E Mail window The Alarm E Mail Filtering Condition window is displayed Figure 2 13 Alarm E Mail Filtering Condition window PRIMEQUEST 580A 540A 580 540 480 440 Figure 2 14 Alarm E Mail Filtering Condition window PRIMEQUEST 520A 520 420 ...

Страница 71: ...lways important but likely be a problem in the future Info Normal events such as partition power on Default All errors Partition Selects the target partition for reporting by mail More than one can be selected Default All partitions Unit Selects a unit to be displayed Select All or Specified with a radio button If All is selected filtering by Unit is not done If Specified is selected filtering by ...

Страница 72: ... 5000 Event communication from PSA It is recommended to back up the setup information after completing the following setup tasks For backing up the settings made here see Section 2 6 Saving Configuration Information z Registering user accounts 2 2 4 1 z Specifying a user account for the certified service engineer in charge 2 2 4 2 z Specifying the system name 2 2 4 3 z Setting the date and time 2 ...

Страница 73: ...istration User List The User List window appears Figure 2 15 User List window Table 2 10 Displayed and setting items in the User List window Item Description User name Displays the user name Full Name Displays the actual name of User Name Privilege Displays permission for the user account Status Displays the current status of this account Enabled or Disabled ...

Страница 74: ...pecify the user name using 8 to 32 characters The characters that can be used to specify the user name are 0 to 9 a to z A to Z and _ The user name must begin with a letter from a to z or A to Z Password Specify the password in 8 to 32 characters The password cannot be one that can be easily guessed by the help of dictionary If the specified password is inappropriate the system prompts for another...

Страница 75: ...o turn on off the power to the partition or the system using the normal procedure Maintenance operations are permitted Operator The user account is permitted to read and specify the PRIMEQUEST system status However it is not permitted to perform user management or LAN configuration change operation Admin The user account is permitted to perform any operation Note Admin means administrator privileg...

Страница 76: ...e same as that described in Section 2 2 4 1 Registering user accounts Specify the user permission for the certified service engineer as CE 2 2 4 3 Specifying the system name Specify a name for the PRIMEQUEST system Only users who are granted Admin permission can change this name This name is also used as the SNMP system name Procedure 1 Click System System Information The System Information window...

Страница 77: ...o be used as the SNMP system name SNMP system name specification cannot be performed separately The system name specified here is displayed on the SNMP Configuration window and it cannot be changed Product Name The product name of the PRIMEQUEST system is displayed Part Number The part number of the PRIMEQUEST system is displayed Note When Read Error is displayed contact your Fujitsu certified ser...

Страница 78: ...erver functions The NTP client function of the MMB makes time adjustments using the other NTP server Each PRIMEQUEST partition uses the NTP server function of the MMB to adjust the time in a partition However the MMB need not be specified for the NTP servers in any of the partitions For stable NTP operation specify multiple NTP servers from the NTP client Fujitsu recommends at least three Procedur...

Страница 79: ...d No setting is required if an NTP server is used Time zone Select a time zone from the pull down menu NTP Sets Enable Disable of the NTP function If the NTP function is set to Enable the MMB makes the NTP server time synchronizations that are set in NTP Server1 to NTP Server3 below The NTP function must also be set to Enable when other clients such as partitions use the MMB as an NTP server Defau...

Страница 80: ... Duplex is set to a value other than AUTO the appropriate cable for use is the same as that for the USER port z For the PRIMEQUEST 580A 540A 520A The REMCS port does not have the Auto MDI X function Use the following cable regardless of the Speed Duplex setting To connect a switching hub device Straight cable To directly connect a PC Crossover cable Note A different cable is used compared with tha...

Страница 81: ...ified service engineer ports and user ports and communication among REMCS ports certified service engineer ports and partition ports are not possible Table 2 14 z VLAN Mode Inter partition communication disconnection mode Inter partition communication is disconnected Communication is possible between the user port and a partition port as well as between the MMB and a partition in the PRIMEQUEST ca...

Страница 82: ...ports N N Y Y N MMB Y Y Y Y Y Partition ports Y N N Y Y Y Communication enabled N Communication disabled VLAN mode User ports Certified engineer ports REMCS ports MMB Partition ports User ports Y N N Y Y Certified engineer ports N Y N Y N REMCS ports N N Y Y N MMB Y Y Y Y Y Partition ports Y N N Y N Y Communication enabled N Communication disabled Port disable mode User ports Certified engineer po...

Страница 83: ...k Configuration Management LAN Port Configuration The Management LAN Port Configuration window is displayed Figure 2 19 Management LAN Port Configuration window PRIMEQUEST 580A 540A 580 540 480 440 Figure 2 20 Management LAN Port Configuration window PRIMEQUEST 520A 520 420 ...

Страница 84: ... communication at 100 Mbps 10M Full Full duplex communication at 10 Mbps 10M Half Half duplex communication at 10 Mbps Default Auto Speed Duplex for MMB 0 PRIMEQUEST 580A 540A 580 540 480 440 Sets Speed Duplex of MMB 0 port Auto Automatic setting 100M Full Full duplex communication at 100 Mbps 100M Half Half duplex communication at 100 Mbps 10M Full Full duplex communication at 10 Mbps 10M Half Ha...

Страница 85: ...d with the System Mirror Option into the CD ROM drive of the MMB console 2 Click Network Configuration License Mirror License The Mirror License window is displayed Figure 2 21 Mirror License window Table 2 18 Displayed and setting items in the Mirror License window Item Description Select the license key file in the license key CD Select the license key file used to validate the license License S...

Страница 86: ... date in the sheet which is supplied with the System Mirror Option in the License box and click the Apply button Then Extended Mirror Mode can be set in each partition Remarks For details on how to set Extended Mirror Mode see 2 5 8 Setting various modes Note The system mirror option must be purchased separately from the PRIMEQUEST main unit ...

Страница 87: ...d with the XPAR option into the CD ROM drive of the MMB console 2 Click Network Configuration License XPAR License The XPAR License window is displayed Figure 2 22 XPAR License window Table 2 19 Displayed and setting items in the XPAR License window Item Description Select the license key file in the license key CD This field is used to select the license key file to enable the license License Sta...

Страница 88: ...on the sheet supplied with the XPAR option into the License boxes and click the Apply button Each partition then becomes ready to be set with XPAR Remarks For details on setting XPAR see Section 2 5 3 Splitting and merging SBs IO Units and IOXs in the PRIMEQUEST 500A 500 series only Note The XPAR option is procured separately from the PRIMEQUEST main unit ...

Страница 89: ... Adding an SB IO Unit and IOX 2 5 4 1 z Removing an SB IO Unit or IOX 2 5 4 2 z Setting a Home IOU 2 5 5 z Setting a reserved SB 2 5 6 z Setting partition names 2 5 7 z Setting various modes 2 5 8 z Starting a partition 2 5 9 z Checking partition information 2 5 10 2 5 1 Partition setting flow When creating partitions follow the workflow in the chart shown below as many times as the number of crea...

Страница 90: ...it and IOX Release the reserved SB 2 5 6 and add it Remove the SB IO Unit and IOX from an existing partition 2 5 4 2 and add them to the target partition Setting the partition name Setting various modes Shut down the target partition Only if the partition is active Reboot the partition Split merge SBs IO Unit and IOXs PRIMEQUEST 500A 500 series only ...

Страница 91: ... Power Control window select Power Off for the partition and click the Apply button Note You may not be able to shut down a partition in which Windows is installed by using the shutdown command from the MMB Web UI In such cases execute the Windows shutdown command to power off the partition For details on how to shut down Windows see the relevant Windows manual or the PRIMEQUEST 580A 540A 520A 500...

Страница 92: ... are not displayed for a powered off partition Power On Powers on the partition Power Off Powers off the partition Power Cycle Forcibly powers off the partition and powers it on again Reset Resets the partition INIT Generates an INIT interrupt for the partition and produces a Dump Force Power Off Forcibly powers off the partition Not specified Takes no action for the partition Note To forcibly ter...

Страница 93: ...has not been registered the Split Configuration menu SB Split window and IOU Split window are not displayed Extended Mirror Mode cannot be set in partitions containing SBs IO Units or IOXs split with XPAR set No split SB IO Unit or IOX can be assigned to a partition that is set in Extended Mirror Mode No SB split with XPAR set can be assigned as the reserved SB of a partition that is set in Extend...

Страница 94: ...e SBs 1 Uncheck the Split check box of the SBs to be merged and click the Apply button The SBs are merged and shown as one merged SB in the window Item Description SB Displays an SB identification number numbers If the SB is already split xA and xB are displayed Partition Displays a partition number or Free which indicates that the SB is free Status Displays the SB status Number of CPUs Displays t...

Страница 95: ...or IOX or merging IO Units or IOXs Only free IO Units and IOXs belonging to a partition can be split Notes If the XPAR license has not been registered the IOU Split window is not displayed 1 Click Partition Split Configuration IOU Split The IOU Split window is displayed Figure 2 25 IOU Split window PRIMEQUEST 580A 540A 580 540 Figure 2 26 IOU Split window PRIMEQUEST 520A 520 ...

Страница 96: ... be merged and click the Apply button The IO Units or IOXs are merged and shown as one merged IO Unit or IOX in the window Item Description IOU Displays an IO Unit identification number numbers If the IO Unit is already split xA and xB are displayed IOX in the PRIMEQUEST 520A 520 only Displays an IOX identification number numbers If the IOX is already split xA and xB are displayed Partition Displa...

Страница 97: ... assigned to a partition that is set in Extended Mirror Mode No SB split with XPAR set can be assigned as the reserved SB of a partition that is set in Extended Mirror Mode Extended Mirror Mode cannot be set in partitions to which split SBs are assigned as reserved SBs XPAR is supported only in the PRIMEQUEST 500A 500 series and the XPAR option is required for setting XPAR Remarks You can add an S...

Страница 98: ...2 52 C122 E001 10EN CHAPTER 2 Setup Figure 2 27 Partition Configuration window PRIMEQUEST 580A 540A 580 540 480 440 Figure 2 28 Partition Configuration window PRIMEQUEST 520A 520 420 ...

Страница 99: ...ame to be set on the OS to make the name easy to recognize Status Displays partition status OK Normal Degraded Component error has occurred The failed component can be disconnected to continue operation Failed Failure has occurred None No partition configuration Specifically SBs and IO Units are not allocated Power Status Displays partition power status On ON Standby Standby SB Displays z to indic...

Страница 100: ...l all the necessary SBs IO Units or IOX are added Item Description Free SB IOU Displays free SBs IO Unit and IOX SBs not belonging to any partition Status Displays the status of a free SBs IO Unit and IOX Note For SB Number of CPUs Displays the number of CPUs installed on the SB Memory Displays the size of memory installed on the SB Note When an SB is extracted and inserted unknown unknown memory ...

Страница 101: ...IOX from a partition while the OS of the partition is operating In such cases set the partition power to the standby state and then remove the SB IO Unit or IOX Procedure 1 Click Partition Partition Configuration The Partition Configuration window is displayed Figure 2 30 Partition Configuration window PRIMEQUEST 580A 540A 580 540 480 440 Figure 2 31 Partition Configuration window PRIMEQUEST 520A ...

Страница 102: ...X at a time 5 Click the Apply button A confirmation dialog box appears 6 Click the OK button The selected SB IO Unit or IOX is removed from the partition and becomes free Item Description SB IOU Displays the SBs IO Units and IOX belonging to the partition Status Displays the status of each SB IO Unit and IOX Note For SB Number of CPUs Displays the number of CPUs installed on the SB Memory Displays...

Страница 103: ... and IOX in a partition as its Home IOU Procedure 1 After SBs IO Units and IOX are included click Partition Partition Configuration The Partition Configuration window is displayed Figure 2 33 Partition Configuration window PRIMEQUEST 580A 540A 580 540 480 440 Figure 2 34 Partition Configuration window PRIMEQUEST 520A 520 420 ...

Страница 104: ...radio buttons of an IO Unit or IOX to be made home Note For the SB to be defined as the home SB always select the one having the smallest number 4 Click the Apply button The specified IO Unit or IOX is set respectively as partition home H is displayed in the corresponding IOU column in the Partition Configuration window Item Description Home IOU IOU Displays the IO Units and IOX that contain BMMs ...

Страница 105: ...split SBs are assigned as reserved SBs The reserved SB defined for a partition is recommended to be one that has the same memory and CPU configurations as those of SBs configured in the partition If the number of CPUs increases during switching to the specified reserved SB additional licenses are required The reserved SB must contain the same type of CPU as those of SBs configured in the partition...

Страница 106: ... is displayed The check boxes are displayed vertically in an SB column that contains the free or reserved SBs Remarks For PRIMEQUEST 500 series the contents of the Reserved SB Configuration window vary with the MMB firmware version If the firmware version is 3 24 or later the window in Figure 2 36 or Figure 2 39 is displayed If the firmware version is earlier than 3 23 the window in Figure 2 37 or...

Страница 107: ... Partition Initialization Figure 2 37 Reserved SB Configuration window PRIMEQUEST 580 540 This window is displayed for an MMB firmware version earlier than 3 23 Figure 2 38 Reserved SB Configuration window PRIMEQUEST 480 440 ...

Страница 108: ...EQUEST 520A and PRIMEQUEST 520 This window is displayed for an MMB firmware version 3 24 or later Figure 2 40 Reserved SB Configuration window PRIMEQUEST 520 This window is displayed for an MMB firmware version earlier than 3 23 Figure 2 41 Reserved SB Configuration window PRIMEQUEST 420 ...

Страница 109: ...ee SB or reserved SB 3 Replacement Condition sets the condition that determines the timing at which the reserved SB is to be switched PRIMEQUEST 580A 540A 520A or PRIMEQUEST 500 series running MMB firmware whose version level is 3 24 or later 4 Click the Apply button Notes To change a reserved SB to a free SB clear its check box in the Reserved SB Configuration window ...

Страница 110: ...his can be performed by users with administrator privilege Procedure 1 Click Partition Partition Configuration The Partition Configuration window is displayed Figure 2 42 Partition Configuration window PRIMEQUEST 580A 540A 580 540 480 440 Figure 2 43 Partition Configuration window PRIMEQUEST 520A 520 420 ...

Страница 111: ...tion name in the Partition Name cell Remarks z The name can include up to 16 characters You can use the following characters 0 9 a z A Z en size space hyphen _ underscore z Set the same name as host name to be set on the OS to make the name easy to recognize 3 Click the Set Partition Name button The name is set for the entered partition ...

Страница 112: ...s IO Units or IOXs split with XPAR set No split SB IO Unit or IOX can be assigned to a partition that is set in Extended Mirror Mode No SB split with XPAR set can be assigned as the reserved SB of a partition that is set in Extended Mirror Mode Extended Mirror Mode cannot be set in partitions to which split SBs are assigned as reserved SBs XPAR is supported only in the PRIMEQUEST 500A 500 series a...

Страница 113: ...C122 E001 10EN 2 67 2 5 Partition Initialization Figure 2 45 Mode window PRIMEQUEST 580 540 Figure 2 46 Mode window PRIMEQUEST 520A 520 Figure 2 47 Mode window PRIMEQUEST 480 440 ...

Страница 114: ...e set in PCI Segment Mode a PCI device under IOU 0 appears in the space under segment 0 and a PCI device under IOU 1 also appears in the space under segment 1 PCI Address Mode setting only for PRIMEQUEST 580A 540A 580 540 480 440 Sets the PCI address mode of a partition The set mode is enabled after the partition is reset Notes Set PCI Bus Mode for the partition that uses Windows Server 2003 as th...

Страница 115: ...e default for Hyper Threading is Disable disabled Dynamic Partitioning current PRIMEQUEST 580A 540A series only Displays whether the Dynamic Partitioning function is enabled Enabled Dynamic Partitioning is enabled Disabled Dynamic Partitioning is disabled Dynamic Partitioning setting PRIMEQUEST 580A 540A series only Specifies whether to enable the Dynamic Partitioning function Enable Enables Dynam...

Страница 116: ... C122 E001 10EN CHAPTER 2 Setup To apply the changes to settings made on this window the partition needs to be turned on off 3 Click the Apply button A confirmation window is displayed 4 Click the OK button ...

Страница 117: ... partition The Power On menu item is not displayed for a powered on partition Conversely the Power Off Power Cycle Reset INIT and Force Power Off menu items are not displayed for a powered off partition Power On Powers on the partition Power Off Powers off the partition Power Cycle Forcibly powers off the partition and powers it on again Reset Resets the partition INIT Generates an INIT interrupt ...

Страница 118: ...Figure 2 50 Information window Table 2 29 Displayed and setting items in the Information window Item Description Partition Name Displays a partition name Status Displays partition status OK The partition is operating normally Degraded The partition contains a failing component operation continues with the failing component isolated Warning The partition is in the warning state a problem will proba...

Страница 119: ...oration using Systemcast Wizard is in progress OS Running The operating system is running OS Shutdown The operating system is shut down Panic The partition is in the panic state Power Off In Progress Partition power off processing is in progress Check Stop The partition has stopped Number of CPU packages Displays the number of CPU packages included in a partition Notes Degraded CPUs are not includ...

Страница 120: ...MB configuration information at a regular interval 2 6 1 MMB Configuration Information Backup This section describes how to back up the MMB configuration information The MMB configuration information is backed up to a remote PC Remarks For backing up the MMB configuration information see the Section 5 6 2 1 Backup Restore Configuration window in the PRIMEQUEST 580A 540A 520A 500 400 Series Referen...

Страница 121: ...e browser saving destination dialog box is displayed 3 Select a saving path and click the OK button This starts the downloading of a configuration information file The default name of the MMB configuration information file to be backed up is as follows MMB_ backup date _ MMB version dat ...

Страница 122: ......

Страница 123: ...amily SUSE Linux Enterprise Server 10 for Itanium Processor Family Microsoft Windows Server 2003 Enterprise Edition for Itanium based Systems Microsoft Windows Server 2003 Datacenter Edition for Itanium based Systems Microsoft Windows Server 2008 for Itanium Based Systems 3 1 2 Types of installation methods This section describes the types of Linux and Windows installation methods and the differen...

Страница 124: ...allation in multiple partitions Ease of operation Local installation Installation using the KVM Display USB keyboard USB mouse and USB floppy drive that are connected to the KVM interface unit Not allowed High Installation without using the KVM Display USB keyboard USB mouse and USB floppy drive that are connected to the server unit Remote installation Installation using SystemcastWizar d Lite Dep...

Страница 125: ...the PRIMEQUEST server is used to install Windows Most of this installation method is automated except for CD ROM DVD replacement and some other operations The High Reliability Tools are automatically installed after Windows installation is completed For details see Section 3 3 3 Windows installation using the installation support tool Manual installation using the KVM Windows is manually installed...

Страница 126: ...ting the installation of the operating system you need to perform the tasks indicated in the Table 3 3 For further information on each task see Chapter 4 Work Required After Operating System Installation Table 3 3 Tasks required after installation Remarks The components required by REMCS functions on the OS side are installed when PSA is installed under Linux Red Hat or Windows REMCS configuration...

Страница 127: ...ig file is a file that contains OS installation option settings etc Use the installation support tool to create a config file Table 3 4 provides an outline of the system requirements for the installation support tool For details see the PRIMEQUEST Installation Support Tool User s Guide Red Hat C122 E005EN or the PRIMEQUEST Installation Support Tool User s Guide SUSE C122 E047EN Table 3 4 System re...

Страница 128: ...tallation procedure is as follows 3 2 1 2 Creating a config file installation support Using the tool choose OS installation options etc For details see the PRIMEQUEST Installation Support Tool User s Guide Red Hat C122 E005EN or the PRIMEQUEST Installation Support Tool User s Guide SUSE C122 E047EN ...

Страница 129: ...tions for installation using the KVM 2 On the MMB Web UI click Partition USB Video DVD Switch The USB Video DVD Switch window appears Remarks For information on how to log in to the MMB see Section 2 2 2 1 Login to and logout from the MMB Web UI Figure 3 2 USB Video DVD Switch window 3 Select the USB Video and DVD radio button for the partition on which you are installing the OS and click the Appl...

Страница 130: ...Partition Partition x Boot Control The Boot Control window appears Figure 3 3 Boot Control window 2 Select Force boot from DVD in Boot Selector and click the Apply button 3 Setting PCI address mode Set PCI Bus Mode as the PCI address mode of the partition in which the operating system is to be installed 1 From the Web UI window of the MMB click Partition Partition x Mode The Mode window appears Fi...

Страница 131: ...the KVM interface unit Then insert the floppy disk containing the configuration file into the USB floppy disk drive 5 Inserting the Linux OS CD ROM disk 1 Insert the CD ROM of the Linux OS to be installed into the KVM DVD ROM drive 6 Turning on the power to the partition Turn on the power to the partition as described below If the power is already on reset the partition 1 On the MMB Web UI window ...

Страница 132: ...ing the OS follow the instructions displayed on the KVM display to insert the supplied CD ROM into the KVM DVD ROM drive and install the attached software program For details of the bundled software package installer see the PRIMEQUEST Installation Support Tool User s Guide Red Hat C122 E005EN or the PRIMEQUEST Installation Support Tool User s Guide SUSE C122 E047EN 3 2 1 6 Work required after ins...

Страница 133: ...he PRIMEQUEST Installation Support Tool User s Guide Red Hat C122 E005EN or the PRIMEQUEST Installation Support Tool User s Guide SUSE C122 E047EN Table 3 5 System requirements for the installation support tool When config file creation is complete the following devices are required for the installation Display USB Keyboard USB Mouse USB floppy disk drive The installation procedure is as follows C...

Страница 134: ...ation Support Tool User s Guide Red Hat C122 E005EN or the PRIMEQUEST Installation Support Tool User s Guide SUSE C122 E047EN 3 2 2 3 Connecting the devices Perform the following steps to connect the devices required for the installation to the partition on which you are installing the Linux OS 1 Connecting the independent KVM switch 1 Connect the independent KVM switch to the USB port of an IO Un...

Страница 135: ...rom the MMB Web UI Figure 3 7 DVD Switch window 3 Select the DVD radio button for the partition on which you are installing the OS and click the Apply button 2 Setting up the EFI Set up the EFI for the partition on which you are installing the OS to ensure that the system will be booted from the DVD ROM 1 On the MMB Web UI window click Partition Partition x Boot Control The Boot Control window app...

Страница 136: ...ector and click the Apply button 3 Connecting a USB floppy disk drive 1 Connect a USB floppy disk drive to the BMM USB port Then insert the floppy disk containing the configuration file into the USB floppy disk drive 4 Inserting the Linux OS CD ROM disk 1 Insert the CD ROM of the Linux OS to be installed into the OPL DVD ROM drive ...

Страница 137: ... partition that is the installation target select Power On Remarks If the power to the partition is already on select Reset 3 Click the Apply button 3 2 2 4 Installing the Linux OS Boot the OS from the CD to install it For details see the PRIMEQUEST Installation Support Tool User s Guide Red Hat C122 E005EN or the PRIMEQUEST Installation Support Tool User s Guide SUSE C122 E047EN Follow the instru...

Страница 138: ...ls of the bundled software package installer see the PRIMEQUEST Installation Support Tool User s Guide Red Hat C122 E005EN or the PRIMEQUEST Installation Support Tool User s Guide SUSE C122 E047EN 3 2 2 6 Work required after installation After installation is complete remove the USB floppy drive from the USB port of the KVM interface unit Then proceed with the work required after Linux OS installa...

Страница 139: ...ystem requirements For details see the PRIMEQUEST SystemcastWizard Lite User s Guide C122 E010EN Table 3 6 Outline of system requirements Classification Compatible environment Hardware PRIMERGY FMV series IA 32 A CD ROM or DVD ROM drive is required The server OS must be one of the following Windows Server 2003 Standard Edition Service Pack 1 or later Windows Server 2003 Enterprise Edition Service ...

Страница 140: ...3 18 C122 E001 10EN CHAPTER 3 Operating System Installation The installation procedure is as follows ...

Страница 141: ...not activate the network across a router Therefore connect the deployment server to the management LAN to which the PRIMEQUEST machine is connected The target partition is started remotely or MMB 0 is used for all communication for backup or restoration Always perform this operation with MMB 0 connected to the management LAN However MMB 0 need not be active PRIMEQUEST Partition Partition Partition...

Страница 142: ...the MMB with RMCP can be specified 1 Click Network Configuration Remote Server Management in the MMB Web UI window The Remote Server Management window is displayed Figure 3 11 Remote Server Management window example 2 Select the applicable user radio button and click the Edit button The Edit User window is displayed Figure 3 12 Edit User window example ...

Страница 143: ...PRIMEQUEST SystemcastWizard Lite User s Guide C122 E010EN 4 Obtaining resources required for installation For the resources required for installation using SystemcastWizard Lite see the PRIMEQUEST SystemcastWizard Lite User s Guide C122 E010EN 5 Checking the statuses of the required service functions Check the service statuses on the deployment server by checking the following Whether you can use ...

Страница 144: ...hich the operating system has been installed For the setting method see Section 2 5 8 Setting various modes After setting the PCI address mode perform the installation work for the Linux OS For details see Chapter 4 Work Required After Operating System Installation PRIMEQUEST 520A 520 420 After installation perform the work required after Linux OS installation For details on the work see Chapter 4...

Страница 145: ...annel connection diagram created in Design the SAN boot environment Retrieve and specify the RAID partition and zone information created in Design the SAN boot environment and the WWPNs recorded in Make SAN boot settings for the PRIMEQUEST machine Install the High Reliability Tools and support drivers Install and set up the High Reliability Tools and drivers For details on these operations see Sec...

Страница 146: ...oducts and Fibre Channel switches see their respective manuals A Fujitsu certified service engineer sets up the SAN boot environment For details contact your Fujitsu certified service engineer 3 3 1 1 Setting up a SAN boot environment The following types of work are required for setting up the SAN boot environment For details on the procedure see Appendix D Installation in the SAN Boot Environment...

Страница 147: ...ne is connected through a single path to the SAN storage Installing Windows on SAN storage by using SystemcastWizard Lite Deployment server Console keyboard display mouse External RAID e g ETERNUS Fibre Channel card Optical fiber cable LAN cable Installing Windows on SAN storage by using the KVM Console keyboard display mouse External RAID e g ETERNUS Fibre Channel card Optical fiber cable Floppy ...

Страница 148: ...Mode The Mode window is displayed Figure 3 14 Mode window PRIMEQUEST 580A 540A 2 Select PCI Bus Mode and click the Apply button The message box A Partition power off on is required in order to make set is displayed click OK to continue processing Note Install Windows when the disk partition is in the appropriate state If installation is attempted in overwrite mode when Linux is already installed i...

Страница 149: ...nts For details see the PRIMEQUEST SystemcastWizard Lite User s Guide C122 E010EN Table 3 7 Outline of system requirements Classification Compatible environment Hardware PRIMERGY FMV series IA 32 A DVD ROM drive is required for reading the Windows Server 2003 IA64 installation DVD The server OS must be one of the following Windows Server 2003 Standard Edition Service Pack 1 or later Windows Server...

Страница 150: ...3 28 C122 E001 10EN CHAPTER 3 Operating System Installation The installation procedure is as follows ...

Страница 151: ...u cannot activate the network across a router Therefore connect the deployment server to the management LAN to which the PRIMEQUEST machine is connected The target partition is started remotely or MMB 0 is used for all communication for backup or restoration Always perform this operation with MMB 0 connected to the management LAN However MMB 0 need not be active PRIMEQUEST Partition Partition Part...

Страница 152: ...zard Lite can be specified If following message is displayed connect the USB floppy disk drive to the KVM USB port and insert the driver disk created following the remark in Step 3 into the floppy disk drive 1 Click Network Configuration Remote Server Management in the MMB Web UI window The Remote Server Management window is displayed Figure 3 16 Remote Server Management window ...

Страница 153: ... window 3 Specify the user management information in the Edit User window and click the Apply button User Name Specify a user name consisting of at least 8 and up to 16 characters Password Specify a password consisting of at least 8 and up to 16 characters Confirm Password Enter the specified password again for confirmation Privilege Select Admin Status Select Enabled ...

Страница 154: ...ee the PRIMEQUEST SystemcastWizard Lite User s Guide C122 E010EN 3 3 2 3 Installing the Windows Create resources on the deployment console and issue a request to install Windows For information on the procedure see the PRIMEQUEST SystemcastWizard Lite User s Guide C122 E010EN Remarks z When installation is completed perform the work required after operating system installation For details on this ...

Страница 155: ...ools required for stable operation Installation using Installation Support Tool for Windows has the following advantages Using an installation floppy disk that has been verified in advance can prevent procedural mistakes during installation Operations for installing Windows in multiple partitions having the same configuration are easy to perform Compared with installation using SystemcastWizard Li...

Страница 156: ...loppy disk in Windows in advance Table 3 8 System requirements for Installation Support Tool for Windows Note Restrictions on installing Windows Server 2003 Enterprise Edition Installation Support Tool for Windows cannot be used to install Windows Server 2003 Enterprise Edition IA64 purchased with a volume license Use SystemcastWizard Lite which is supplied with the PRIMEQUEST product Classificati...

Страница 157: ... Support Tool for Windows User s Guide C122 048EN Set up the device Turn on power to partitions Execute the installation preparation script Begin Windows setup Install the High Reliability Tools 1 Remove the storage devices in which Windows is not to be installed 2 Connect the USB floppy disk drive 3 Set PCI address mode PRIMEQUEST 580A 540A 580 540 480 440 4 Connect the DVD drive display mouse an...

Страница 158: ...he SAN disk The installation procedure assumes that all the following devices are connected Keyboard Display Mouse SAN storage unit e g ETERNUS Fibre Channel card Optical fiber cable Floppy disk drive It must be prepared separately This is connected during the Windows installation procedure Remarks For the connections between the PRIMEQUEST machine and ETERNUS units see the topologies shown in the...

Страница 159: ...ections for installation using the KVM 2 On the MMB Web UI click Partition USB Video DVD Switch The USB Video DVD Switch window appears Remarks For information on how to log in to the MMB see Section 2 2 2 1 Login to and logout from the MMB Web UI Figure 3 19 USB Video DVD Switch window 3 Select the USB Video and DVD radio button for the partition on which you are installing the OS and click the A...

Страница 160: ...122 E024 referred to as the Drivers CD in this document Prepare a driver disk on a separate PC running Windows Preparing an FC driver disk 1 Format a floppy disk 2 Insert the Drivers CD into the drive of the separate PC 3 Using Explorer access the following folder on the Drivers CD E Drivers FC Emulex assuming that E is the CD ROM drive 4 Select all files in the folder and copy them to the floppy ...

Страница 161: ...e 5 Select DVD Acpi xxxxxxxx and press the Enter key If an active area has been allocated to the hard disk the message shown below appears While the message is displayed press any key to boot the system from the DVD ROM drive 6 The Windows Server 2003 setup screen is displayed The following message is displayed at the bottom of the setup screen immediately after the screen is displayed This messag...

Страница 162: ...ollowing the instructions from the setup program For details see the OS manual When a message requesting a floppy disk appears during installation insert the driver disk and press the Enter key Remarks The setup program requests a product ID during installation The product ID location varies depending on the installed operating system and purchase method To specify additional SCSI adapters CD ROM ...

Страница 163: ...ystem Windows Server 2003 Datacenter or Windows Server 2003 Enterprise Edition has been added to the EFI Boot Manager screen Select this added item from the boot menu to start Windows 10 Install the High Reliability Tools after Windows startup For details see 3 3 6 1 Installation using the PRIMEQUEST Software Installer Installed operating system Purchase method Product ID location Windows Server 2...

Страница 164: ...llation program prompts you to press the Fx function key press the ESC key and then the number key corresponding to x If the installation program prompts you to press the Page Down key press the ESC key and then the key If the installation program prompts you to press the Page Up key press the ESC key and then the key Note Press the number key key or key promptly after pressing the ESC key If you ...

Страница 165: ...s UTF 8 If terminal connection software that does not support UTF 8 is used corrupt characters appear Select a keyboard type from the following list To continue setup press the Enter key To quit setup press the F3 key 106 Japanese Keyboard Including USB 101 English Keyboard Including USB NEC 98 Layout USB Keyboard USB Keyboard Scroll down ...

Страница 166: ...are as follows Table 3 10 Setting items of the terminal software Prepare and apply driver disks in advance by following steps 3 in Section 3 3 4 3 Installing Windows When text setup on the blue screen is completed follow the procedure below to make the appropriate settings 1 Start Tera Term When the following window is displayed press the ESC and TAB keys Figure 3 21 Tera Term startup window Setti...

Страница 167: ...on 2 When the following window is displayed press the Enter key Figure 3 22 Setup window 3 When the following window is displayed confirm the displayed contents press the ESC key and then the 8 key Figure 3 23 Software license agreement window ...

Страница 168: ...rd input window is displayed enter a password and press the Enter key The password input window is displayed only in custom installation Figure 3 24 Product key input window 5 When the following window is displayed the operating system restarts Do not press any key for key input until it restarts though the restart takes about 15 minutes Figure 3 25 OS restart window ...

Страница 169: ...disk The installation procedure assumes that all the following devices are connected Independent KVM switch Keyboard Display Mouse SAN storage unit e g ETERNUS Fibre Channel card Optical fiber cable Floppy disk drive It must be prepared separately This is connected during the Windows installation procedure Remarks For the connections between the PRIMEQUEST machine and ETERNUS units see the topolog...

Страница 170: ...ent KVM switch to the USB port and VGA interface of the IO Unit Figure 3 26 Example of connections for installation using the independent KVM switch 2 On the MMB Web UI click Partition DVD Switch The DVD Switch window appears Remarks For information on how to log in to the MMB see Section 2 2 2 1 Login to and logout from the MMB Web UI Figure 3 27 DVD Switch window 3 Select the radio button of the...

Страница 171: ...the Fibre Channel card driver FC driver stored on the PRIMEQUEST Drivers CD for Microsoft Windows Server 2003 C122 E024 referred to as the Drivers CD in this document Prepare a driver disk on a separate PC running Windows Preparing an FC driver disk 1 Format a floppy disk 2 Insert the Drivers CD into the drive of the separate PC 3 Using Explorer access the following folder on the Drivers CD E Driv...

Страница 172: ... drive of the separate PC 3 Using Explorer access the following folder on the Drivers CD E Drivers SAS LSILogic assuming that E is the CD ROM drive 4 Select all files in the folder and copy them to the floppy disk 4 Click the Apply button The EFI Boot Manager message is displayed on the display connected to the KVM Note Confirm that the USB floppy disk drive is not installed If a floppy disk is in...

Страница 173: ...displayed 7 Install the driver manually 1 When the following message appears press the S key 2 When the following message appears connect the USB floppy disk drive To connect the drive to an IOU connect it to the USB port on the left side as viewed from the back of the main unit To connect it to an IOX connect it to the lower USB port 3 Insert the driver disk created in step 3 into the floppy disk...

Страница 174: ...e CoA sticker is one of the supplied items be sure to read the bundled Important Notice and then affix the sticker to the main unit 3 Use a CoA sticker with an Enterprise marking If more than one CoA sticker has that marking be careful not to use more than one product ID during installation 4 Use a CoA sticker of the Datacenter that carries a 4 CPU marking Emulex LPX000 PCI Fibre Channel HBA LSI L...

Страница 175: ...n an IO Unit z Key operations for terminal software differ from those for screen display If the installation program prompts you to press the Fx function key press the ESC key and then the number key corresponding to x If the installation program prompts you to press the Page Down key press the ESC key and then the key If the installation program prompts you to press the Page Up key press the ESC ...

Страница 176: ...supports UTF 8 If terminal connection software that does not support UTF 8 is used corrupt characters appear Select a keyboard type from the following list To continue setup press the Enter key To quit setup press the F3 key 106 Japanese Keyboard Including USB 101 English Keyboard Including USB NEC 98 Layout USB Keyboard USB Keyboard Scroll down ...

Страница 177: ...follows Table 3 12 Setting items of the terminal software Prepare and apply driver disks in advance by following steps 3 in Section 3 3 4 3 Installing Windows When text setup on the blue screen is completed follow the procedure below to make the appropriate settings 1 Start Tera Term When the following window is displayed press the ESC and TAB keys Figure 3 29 Tera Term startup window Setting item...

Страница 178: ... Operating System Installation 2 When the following window is displayed press the Enter key Figure 3 30 Setup window 3 When the following window is displayed press the ESC key and 8 key Figure 3 31 Software license agreement window ...

Страница 179: ... window is displayed enter a password and press the Enter key The password input window is displayed only in custom installation Figure 3 32 Product key input window 5 When the following window is displayed the operating system restarts Do not press any key for key input until it restarts though the restart takes about 15 minutes Figure 3 33 OS restart window ...

Страница 180: ...ty Tools need to be manually installed after Windows is installed 3 3 6 1 Installation using the PRIMEQUEST Software Installer The PRIMEQUEST Software Installer automatically checks whether the applicable tools are installed and it automatically installs the tools that have not been installed The installer applies the latest drivers This section describes the installation procedure using the PRIME...

Страница 181: ...n an installation completion message appears click the Exit button 7 To complete installation restart the partition At this point installation using the PRIMEQUEST Software Installer is completed Remarks Log files are created at the following locations z Software installation results systemroot system32 LogFiles PQSetup log z Driver installation results systemroot system32 LogFiles pqdad yyyymmdd ...

Страница 182: ...r Supported Neterion LAN driver Emulex FC Driver Fibre Channel card driver LSI Logic SCSI Driver SCSI driver LSI Logic SAS Driver SAS driver HP DAT72 Driver DAT72 driver TANDBERG LTO2 Driver LTO2 driver Quantum LTO3 Driver LTO3 driver Driver management tool Intel PROSet Provides the Intel LAN load balance function etc Broadcom Advanced Controller Suite BACS Provides an on board LAN driver with loa...

Страница 183: ... cards Fibre Channel cards etc are mounted in the IO Unit of the partition z SIRMS and HRM server are installed only under a Japanese version of Windows SIRMS SIRMS MNS and HRM server are installed only under a Japanese version of Windows z Some messages may appear during the installation process When a dialog box with warning that a driver has not passed Windows logo testing is displayed during i...

Страница 184: ...isplay Adapter and then select Disable from the menu 4 Restart the system according to the popup instruction 3 3 7 2 Installing the multipath driver After setting up the operating system in a single path environment make Fibre Channel cable settings in a multipath environment Install the multipath driver and then make the cable settings in the multipath environment Notes Do not establish a multipa...

Страница 185: ...perating system installation return it back to its original location Start the operating system when the environment designed for the system has been configured This ends installation of Windows To use the system in a single path environment install the ETERNUS device driver For details see the information available under the following URL ...

Страница 186: ......

Страница 187: ...ST 580A 540A 580 540 480 440 4 5 PRIMEQUEST 520A 520 420 4 6 PSA monitoring setup Set up S M A R T Set up Watchdog Linux or Windows PRIMEQUEST 500A 500 400 series common 4 8 Dump environment setup Set up a dump environment Linux Red Hat only PRIMEQUEST 500A 500 400 series common 4 9 Windows PRIMEQUEST 500A 500 400 series common 4 10 NTP client setup Set up NTP clients Linux or Windows PRIMEQUEST 5...

Страница 188: ...tion Remarks The components required by REMCS functions on the OS side are installed when PSA is installed under Linux Red Hat or Windows REMCS configuration will be performed by the certified service engineer in charge PSA installation and PSA monitoring setting are required ...

Страница 189: ...nstaller or SystemcastWizard Lite to install PSA If you want to manually install PSA see Chapter 4 Manual PSA Installation in the PRIMEQUEST 500A 500 400 Series Reference Manual Tools Operation Information C122 E074EN For details on the installation support tool see the PRIMEQUEST Installation Support Tool User s Guide Red Hat C122 E005EN For details on the bundled software package installer see t...

Страница 190: ...or on the PSA window of the MMB Web UI may occur and errors detected by the PSA are not reported 4 2 1 Checking the management LAN settings This section describes how to check the management LAN settings For communication of PSA with the MMB via the management LAN the NIC connected to the management LAN on the partition side must be active 1 Checking the settings for the NIC of the management LAN ...

Страница 191: ...rrier 0 collisions 0 txqueuelen 1000 RX bytes 390009908 371 9 MiB TX bytes 809006934 771 5 MiB eth1 Link encap Ethernet HWaddr 00 0E 0C 21 83 97 inet addr 192 168 0 162 Bcast 10 24 17 255 Mask 255 255 255 0 inet6 addr fe80 20e cff fe21 8397 64 Scope Link UP BROADCAST RUNNING MULTICAST MTU 1500 Metric 1 RX packets 1538726 errors 0 dropped 0 overruns 0 frame 0 TX packets 356 errors 0 dropped 0 overr...

Страница 192: ...o choices of duplication software Bonding or PRIMECLUSTER GLS Either one monitors the transmission line that extends to the external switch and if it detects an error switches the transmission line As shown in Figure 4 1 PRIMEQUEST achieves duplication of the transmission line from the partition to the external switch by including the external switch connected to the MMB user port in the target of...

Страница 193: ...A 580 540 480 440 Figure 4 2 Concept of management LAN duplication in PRIMEQUEST a configuration characterized by improved reliability PRIMEQUEST MMB 1 NIC MMB 0 NIC Partition Virtual interface NIC 0 NIC 1 User port External switch 1 External switch 2 User port Remote system ...

Страница 194: ...Bonding interface The following example of the etc modprobe conf file assumes that the management LAN interface names are eth0 and eth1 In the configuration shown in Figure 4 2 the IP address of external switch 1 is 10 20 100 10 and the IP address of external switch 2 is 10 20 100 11 vi etc modprobe conf alias management LAN NIC interface name 1 e100 alias management LAN NIC interface name 2 e100 ...

Страница 195: ...resses in the ifcfg file as the IP addresses for Bonding Modify the ifcfg file by rewriting it as described for duplication setting in this item Management LAN NIC interface 0 ifcfg interface name 1 Example ifcfg eth0 Management LAN NIC interface 1 ifcfg interface name 2 Example ifcfg eth1 Bonding interface ifcfg Bonding interface name Example ifcfg bond0 A hardware address is required for setting...

Страница 196: ...LTICAST MTU 1500 Metric 1 RX packets 1107704 errors 0 dropped 0 overruns 0 frame 0 TX packets 2653820 errors 0 dropped 0 overruns 0 carrier 0 collisions 0 txqueuelen 1000 RX bytes 390009908 371 9 MiB TX bytes 809006934 771 5 MiB vi etc sysconfig network scripts ifcfg NIC interface name Change or add the subsequent lines as shown below you can arrange the lines in any order DEVICE NIC interface nam...

Страница 197: ...ate the management LAN using PRIMECLUSTER GLS see the PRIMECLUSTER GLS manuals Only the NIC switching method can be used for the duplication of the management LAN At this time specify the external switches connected to the MMB user ports shown in Figure 4 1 and Figure 4 2 as the monitored hubs DEVICE eth1 BOOTPROTO none HWADDR 00 04 23 AB 94 5F ONBOOT yes MASTER bond0 SLAVE yes DEVICE bond0 BOOTPR...

Страница 198: ...t the PSA Command syntax 4 2 2 Checking the SELinux function settings On the OS redhat Linux running in the partition on which you are installing the PSA check whether SELinux functions are enabled If they are disable them The PRIMEQUEST system runs with the SELinux functions disabled Do as follows to verify whether the SELinux function is disabled If not disable it by editing the config file etc ...

Страница 199: ... of the MMB icmp icmp type0 icmp type8 to the virtual IP address of the MMB 1 Release the port only when a PCL linkage is used Use the iptables command for checking the firewall setting 2 web mmb communication port 3 This is communication for the MMB 5000 port Because the partition operates as the client under this communication the port number used at the partition side is undefined Any number fr...

Страница 200: ...d If SNMP trap sending from the partition is defined a trap is also sent when authentication fails Multiple destinations can be defined by specifying multiple pairs of the trapsink and trap2sink lines If COMMUNITY is not specified the character string previously specified by the trapcommunity directive is used The trapcommunity command sets the default community string used to send traps When usin...

Страница 201: ...t snmp snmpd conf file in the trap sender u secName Specifies the SNMPv3 account It must be the same as the setting in the manager l secLevel Specifies one of the following according to the security level of SNMPv3 messages Table 4 2 secLevel settings a authProtocol Specifies MD5 or SHA as the protocol used to authenticate SNMPv3 messages If SHA is to be used a package must be created using openss...

Страница 202: ...ay be omitted X privPassword Specifies an encryption password eight or more characters The password must be the same as the setting in the manager If encryption is included in the security level specified by the l option this option is valid otherwise it may be omitted Example When you want to send SNMPv3 traps with the PRIMEQUEST account with authentication and encryption enabled to port 162 of t...

Страница 203: ...example if the trap transfer destination is a Linux machine the following message is added to syslog when snmptrapd receives the trap and this indicates that the trap transfer destination can correctly receive such traps Aug 17 12 00 53 shaka snmptrapd 2600 2005 08 17 12 00 53 pq server fujitsu com 192 168 0 162 via 192 168 0 162 TRAP SNMP v1 community public NET SNMP MIB netSnmpAgentOIDs 10 Cold ...

Страница 204: ...PSA is active Command syntax Example PSA is active if the following processes under opt FJSVpsa bin are displayed 2 If PSA is active use the service command to stop PSA Command syntax ps ax grep psa ps ax grep psa 4562 S 0 00 opt FJSVpsa bin pm o 70 etc opt FJSVpsa global pmpsa conf 4563 S 0 18 opt FJSVpsa bin loggetd p 4564 S 0 06 opt FJSVpsa bin sisp p 4565 S 0 00 opt FJSVpsa bin mmbm p 4566 S 0...

Страница 205: ...change to any value in up to 34 hexadecimal digits provided that it is unique throughout the partitions in the same cabinet Example To change the value of oldEngineID to 0x19760523 6 Enter the service command to start snmpd Command syntax 7 Change the current directory to opt FJSVpsa sh to regenerate the snmpv3 password used for the PSA internal communication Command syntax ps ax grep snmpd ps ax ...

Страница 206: ...ands in the order shown stop the PSA service and perform update installation for the PSA package Note If the PEXU has been mounted use PSA 1 10 or later Command syntax Update from PSA 1 2 X X or later Update from PSA 1 1 X X X X X X indicates the PSA version snmpsetup sh install sbin service y30FJSVpsa start sbin service y30FJSVpsa stop bin rpm Uvh FJSVpsa X X X X ia64 rpm sbin service y30FJSVpsa ...

Страница 207: ...ommand syntax 4 2 11 SIRMS uninstallation Using the following commands uninstall the two SIRMS packages Command syntax Note SIRMS is a function to collect software configuration information when REMCS is in use It must be installed at the time of PSA installation However you do not need to install it if you perform batch installation using the PRIMEQUEST installation support tool or bundled softwa...

Страница 208: ...ystemcastWizard Lite to install PSA If you want to manually install PSA see Chapter 4 Manual PSA Installation in the PRIMEQUEST 500A 500 400 Series Reference Manual Tools Operation Information C122 E074EN For details on the installation support tool see the PRIMEQUEST Installation Support Tool User s Guide Red Hat C122 E005EN For details on the bundled software package installer see the PRIMEQUEST...

Страница 209: ...or on the PSA window of the MMB Web UI may occur and errors detected by the PSA are not reported 4 3 1 Checking the management LAN settings This section describes how to check the management LAN settings For communication of PSA with the MMB via the management LAN the NIC connected to the management LAN must be active 1 Checking the settings for the NIC of the management LAN Execute the following ...

Страница 210: ...0 TX packets 2653820 errors 0 dropped 0 overruns 0 carrier 0 collisions 0 txqueuelen 1000 RX bytes 390009908 371 9 MiB TX bytes 809006934 771 5 MiB eth1 Link encap Ethernet HWaddr 00 0E 0C 21 83 97 inet addr 192 168 0 162 Bcast 10 24 17 255 Mask 255 255 255 0 inet6 addr fe80 20e cff fe21 8397 64 Scope Link UP BROADCAST RUNNING MULTICAST MTU 1500 Metric 1 RX packets 1538726 errors 0 dropped 0 overr...

Страница 211: ...ows an example of the ifcfg file on the assumption that the management NIC LAN interface is eth0 sbin ifconfig a sbin ifconfig a eth0 Link encap Ethernet HWaddr 00 D0 B7 53 89 C3 inet addr 10 24 17 149 Bcast 10 24 17 255 Mask 255 255 255 0 inet6 addr fe80 2d0 b7ff fe53 89c3 64 Scope Link UP BROADCAST RUNNING MULTICAST MTU 1500 Metric 1 RX packets 1107704 errors 0 dropped 0 overruns 0 frame 0 TX pa...

Страница 212: ...e network interface Command syntax To make the management LAN NIC settings effective PSA need to be restarted Command syntax DEVICE eth0 BOOTPROTO static HWADDR 00 D0 B7 53 89 C3 ONBOOT yes BROADCAST 192 168 0 255 IPADDR 192 168 0 1 NETMASK 255 255 255 0 sbin service network restart sbin service y30FJSVpsa stop sbin service y30FJSVpsa start ...

Страница 213: ...whether SELinux functions are enabled If they are disable them The PRIMEQUEST system runs with the SELinux functions disabled Do as follows to verify whether the SELinux function is disabled If not disable it by editing the config file etc selinux config z Checking the setting z Changing the setting cd etc selinux more config SELINUX disabled vi etc selinux config Change the following definition S...

Страница 214: ... type8 to the virtual IP address of the MMB 1 Release the port only when a PCL linkage is used Use the iptables command for checking the firewall setting 2 web mmb communication port 3 This is communication for the MMB 5000 port Because the partition operates as the client under this communication the port number used at the partition side is undefined Any number from tcp 1025 to 65535 is selected...

Страница 215: ...ined a trap is also sent when authentication fails Multiple destinations can be defined by specifying multiple pairs of the trapsink and trap2sink lines If COMMUNITY is not specified the character string previously specified by the trapcommunity directive is used The trapcommunity command sets the default community string used to send traps When using trapcommunity to set the community string spec...

Страница 216: ... the security level of SNMPv3 messages Table 4 3 secLevel settings a authProtocol Specifies MD5 or SHA as the protocol used to authenticate SNMPv3 messages If SHA is to be used a package must be created using openssl that is installed This option is valid when authentication is included in the security level specified by the l option It can be omitted if authentication is not included A authPasswo...

Страница 217: ...f encryption is included in the security level specified by the l option this option is valid otherwise it may be omitted Example When you want to send SNMPv3 traps with the PRIMEQUEST account with authentication and encryption enabled to port 162 of the manager with IP address 192 168 0 162 After setting the trap transfer destination restart snmpd by executing the following command After restart ...

Страница 218: ... example if the trap transfer destination is a Linux machine the following message is added to syslog when snmptrapd receives the trap and this indicates that the trap transfer destination can correctly receive such traps Aug 17 12 00 53 shaka snmptrapd 2600 2005 08 17 12 00 53 pq server fujitsu com 192 168 0 162 via 192 168 0 162 TRAP SNMP v1 community public NET SNMP MIB netSnmpAgentOIDs 10 Cold...

Страница 219: ...PSA is active Command syntax Example PSA is active if the following processes under opt FJSVpsa bin are displayed 2 If PSA is active use the service command to stop PSA Command syntax ps ax grep psa ps ax grep psa 4562 S 0 00 opt FJSVpsa bin pm o 70 etc opt FJSVpsa global pmpsa conf 4563 S 0 18 opt FJSVpsa bin loggetd p 4564 S 0 06 opt FJSVpsa bin sisp p 4565 S 0 00 opt FJSVpsa bin mmbm p 4566 S 0...

Страница 220: ... to any value in up to 34 hexadecimal digits provided that it is unique throughout the partitions in the same cabinet Example To change the value of oldEngineID to 0x19760523 6 Enter the service command to start snmpd Command syntax 7 Change the current directory to opt FJSVpsa sh to regenerate the snmpv3 password used for the PSA internal communication Command syntax ps ax grep snmpd ps ax grep s...

Страница 221: ... the PSA service and perform update installation for the PSA package Note If the PEXU has been mounted use PSA 1 10 or later Command syntax X X X X indicates the PSA version 4 3 9 SIRMS update installation Using the following commands perform update installation for the two SIRMS packages Command syntax X X X X indicates the version snmpsetup sh install sbin service y30FJSVpsa start sbin service y...

Страница 222: ...he following commands uninstall the two SIRMS packages Command syntax Note SIRMS is a function to collect software configuration information when REMCS is in use It must be installed at the time of PSA installation However you do not need to install it if you perform batch installation using the PRIMEQUEST installation support tool or bundled software package installer sbin service y30FJSVpsa stop...

Страница 223: ... to install PSA If you want to manually install PSA see Chapter 4 Manual PSA Installation in the PRIMEQUEST 500A 500 400 Series Reference Manual Tools Operation Information C122 E074EN For details on the installation support tool see the PRIMEQUEST Installation Support Tool User s Guide SUSE C122 E047EN For details on the bundled software package installer see the PRIMEQUEST Bundled Software Packa...

Страница 224: ...tions 2 Added Port Port numbers are not checked for duplication when contents are added to the fj webgate 24450 services file They may need to be changed Note If the IP address of the MMB or the IP address of the management LAN on the partition side has been changed be sure to restart the PSA Otherwise a display error on the PSA window of the MMB Web UI may occur and errors detected by the PSA are...

Страница 225: ...t addr 192 168 1 10 Bcast 192 168 1 255 Mask 255 255 255 0 inet6 addr fe80 2d0 b7ff fe53 89c3 64 Scope Link UP BROADCAST RUNNING MULTICAST MTU 1500 Metric 1 RX packets 1107704 errors 0 dropped 0 overruns 0 frame 0 TX packets 2653820 errors 0 dropped 0 overruns 0 carrier 0 collisions 0 txqueuelen 1000 RX bytes 390009908 371 9 MiB TX bytes 809006934 771 5 MiB eth1 Link encap Ethernet HWaddr 00 0E 0C...

Страница 226: ...420 0000 01 08 0 Command syntax Example As the result of command execution for eth0 and eth1 these two interfaces match the NICs for the management LAN Note The following example assumes that a PRIMEQUEST 580A 540A 580 540 480 440 is used 3 Execute the following command for the found NIC for the management LAN and record the hardware address Command syntax Example Command execution for eth0 and et...

Страница 227: ... inet addr 192 168 1 10 Bcast 192 168 1 255 Mask 255 255 255 0 inet6 addr fe80 2d0 b7ff fe53 89c3 64 Scope Link UP BROADCAST RUNNING MULTICAST MTU 1500 Metric 1 RX packets 1107704 errors 0 dropped 0 overruns 0 frame 0 TX packets 2653820 errors 0 dropped 0 overruns 0 carrier 0 collisions 0 txqueuelen 1000 RX bytes 390009908 371 9 MiB TX bytes 809006934 771 5 MiB sbin ifconfig eth1 Link encap Ethern...

Страница 228: ...der the redundant physical configuration The duplication software monitors the transmission line that extends to the external switch and if it detects an error switches the transmission line As shown in Figure 4 3 PRIMEQUEST achieves duplication of the transmission line from the partition to the external switch by including the external switch connected to the MMB user port in the target of monito...

Страница 229: ...00 series common Figure 4 4 Concept of management LAN duplication in PRIMEQUEST a configuration characterized by improved reliability PRIMEQUEST MMB 1 NIC MMB 0 NIC Partition Virtual interface NIC 0 NIC 1 User port External switch 1 External switch 2 User port Remote system ...

Страница 230: ...e of the NIC interface for the management LAN Change or add lines as shown below Example The editing of the ifcfg file shown in the following example assumes that the Bonding interface is ifcfg bond0 Then enter start for the network service to activate the Bonding interface Command syntax rcnetwork stop rm etc sysconfig network ifcfg eth id hardware address vi etc sysconfig network ifcfg bonding i...

Страница 231: ...n the PRIMECLUSTER GLS manuals After configuring the duplication settings by the GLS restart the network service and then restart the PSA Command syntax SUSE 10 1 Add the line shown below to the end of etc modprobe conf local Name the Bonding interface bondN where N is a number assigned in ascending order such as 0 1 2 1 For the configuration shown in Figure 4 5 specify one IP address For the conf...

Страница 232: ...d reliability 2 Edit the ifcfg file for the relevant interface in etc sysconfig network If the file does not exist create it To edit the file first stop the network Bonding interface name ifcfg Bonding interface name Example ifcfg bond0 Remarks If the relevant interface for the management LAN is in etc sysconfig network disable it by deleting it File name of the ifcfg file of the interface for the...

Страница 233: ...s for the management LAN effective PSA needs to be restarted Command syntax rcnetwork stop rm etc sysconfig network ifcfg eth id hardware address vi etc sysconfig network ifcfg Bonding interface name ifcfg bond0 BOOTPROTO static MTU REMOTE_IPADDR IPADDR 192 168 16 138 Same subnet as the MMB NETMASK 255 255 255 0 BROADCAST 192 168 16 255 STARTMODE onboot BONDING_MASTER yes BONDING_SLAVE_0 bus pci 0...

Страница 234: ...vate YaST Command syntax 3 Select Network Devices Network Card from the menu and proceed to the network card selection window 4 From the network cards displayed in the Network Card Configuration window select the card NIC for the management LAN that has the name recorded in step 1 Note The name that is recorded in step 1 may not be displayed completely according to YaST specifications As shown in ...

Страница 235: ... controller matches the last part of the name recorded in step 1 5 Go to the Network Address Setup window to set up the network card Confirm that the value of Configuration Name includes the hardware address that was checked in 1 Checking the settings for the NIC of the management LAN Check Static address setup and specify the IP address and the subnet mask Note The specified IP address and the IP...

Страница 236: ...JSVpsa path syslogd fifo Operation not permitted Remarks Use the and keys to move the cursor up and down on the YaST screen 1 Enter the following command to confirm the active syslog daemon If SYSLOG_DAEMON If syslog ng is displayed for SYSLOG_DAEMON sbin syslog ng is running as the syslog daemon If SYSLOG_DAEMON If syslog is displayed for SYSLOG_DAEMON sbin syslogd is running as the syslog daemon...

Страница 237: ...tive syslog daemon under Profile Name The active syslog daemon is the one that was confirmed in step 1 If you do not find the active syslog daemon under Profile Name the subsequent settings need not be made In this case select Abort from the bottom menu and press the Enter key to exit from this window Then select Quit from the bottom menu and press the Enter key to quit YaST If you find the active...

Страница 238: ...2 C122 E001 10EN CHAPTER 4 Work Required After Operating System Installation Figure 4 10 AppArmor Profile select screen 4 Press the Tab key to select Add Entry from the bottom menu and press the Enter key ...

Страница 239: ...ter key s Figure 4 11 Entry addition and selection screen 5 Enter var opt FJSVpsa path syslog_fifo at the Enter or modify Filename field and press the Tab key Next in the Permissions field use the Space key to mark the Read and Write checkboxes Press the Tab key to select OK and press the Enter key Figure 4 12 Adding the Profiles Entry screen ...

Страница 240: ...changes made in step 5 have been applied Figure 4 13 Entry list screen 7 Press the Tab key to select Done from the bottom menu The Save changes to the Profile screen is then displayed From the Save changes to the Profile screen select Yes and press the Enter key Figure 4 14 Saving the profiles screen ...

Страница 241: ...o quit YaST 9 Restart AppArmor 10 Restart the syslog services 4 4 3 SELinux function By default the SELinux function is disabled on the PRIMEQUEST series machine after OS installation Do not use the SELinux function etc init d boot apparmor restart Reloading AppArmor profiles done etc init d syslog restart Shutting down syslog services done Starting syslog services done ...

Страница 242: ... icmp icmp type0 icmp type8 to the virtual IP address of the MMB 1 Release the port only when a PCL linkage is used Use the iptables command for checking the firewall setting 2 web mmb communication port 3 This is communication for the MMB 5000 port Because the partition operates as the client under this communication the port number used at the partition side is undefined Any number from tcp 1025...

Страница 243: ... trap is also sent when authentication fails Multiple destinations can be defined by specifying multiple pairs of the trapsink and trap2sink lines If COMMUNITY is not specified the character string previously specified by the trapcommunity directive is used The trapcommunity command sets the default community string used to send traps When using trapcommunity to set the community string specify th...

Страница 244: ... snmpd conf file in the trap sender u secName Specifies the SNMPv3 account It must be the same as the setting in the manager l secLevel Specifies one of the following according to the security level of SNMPv3 messages Table 4 4 secLevel settings a authProtocol Specifies MD5 or SHA as the protocol used to authenticate SNMPv3 messages If SHA is to be used a package must be created using openssl that...

Страница 245: ...may be omitted X privPassword Specifies an encryption password eight or more characters The password must be the same as the setting in the manager If encryption is included in the security level specified by the l option this option is valid otherwise it may be omitted Example When you want to send SNMPv3 traps with the PRIMEQUEST account with authentication and encryption enabled to port 162 of ...

Страница 246: ...trapd 2600 2005 08 17 12 00 53 pq server fujitsu com 192 168 1 10 via 192 168 1 10 TRAP SNMP v1 community public NET SNMP MIB netSnmpAgentOIDs 10 Cold Start Trap 0 Uptime 0 00 00 17 Note If the operating system is SUSE Linux Enterprise Server 9 Service Pack 2 and direct reporting of traps to the SNMP manager has been set 0 0 0 0 is reported as the Agent Address value in the SNMP layer in reported ...

Страница 247: ... MMB Notes z Make this setting only if required z The setting is required for linkage with operation management software such as Systemwalker The destinations of trap and e mail sending via the MMB can be set with the MMB Web UI See Section 5 1 2 System SNMP setting for the MMB trap destination See Section 2 2 3 5 SMTP settings for the e mail destination ...

Страница 248: ...PSA is active Command syntax Example PSA is active if the following processes under opt FJSVpsa bin are displayed 2 If PSA is active use the following command to stop PSA Command syntax ps ax grep psa ps ax grep psa 4562 S 0 00 opt FJSVpsa bin pm o 70 etc opt FJSVpsa global pmpsa conf 4563 S 0 18 opt FJSVpsa bin loggetd p 4564 S 0 06 opt FJSVpsa bin sisp p 4565 S 0 00 opt FJSVpsa bin mmbm p 4566 S...

Страница 249: ... change to any value in up to 34 hexadecimal digits provided that it is unique throughout the partitions in the same cabinet Example To change the value of oldEngineID to 0x19760523 6 Enter the following command to start snmpd Command syntax 7 Change the current directory to opt FJSVpsa sh to regenerate the snmpv3 password used for the PSA internal communication Command syntax ps ax grep snmpd ps ...

Страница 250: ...g commands in the order shown stop the PSA service and perform update installation for the PSA package Note If the PEXU has been mounted use PSA 1 10 or later Command syntax Update from PSA 1 2 X X or later Update from PSA 1 1 X X X X X X indicates the PSA version snmpsetup sh install etc init d y30FJSVpsa start etc init d y30FJSVpsa stop bin rpm Uvh FJSVpsa X X X X ia64 rpm etc init d y30FJSVpsa ...

Страница 251: ...tion Linux SUSE PRIMEQUEST 500A 500 400 series common 4 4 9 PSA uninstallation Using the following commands in the order shown stop the PSA service and uninstall the PSA package Command syntax etc init d y30FJSVpsa stop bin rpm e FJSVpsa ...

Страница 252: ...l the PSA see Chapter 4 Manual PSA Installation in the PRIMEQUEST 500A 500 400 Series Reference Manual Tools Operation Information C122 E074EN For details on installation using the PRIMEQUEST Software Installer see Section 3 3 6 1 Installation using the PRIMEQUEST Software Installer For details on installation using SystemcastWizard Lite see the PRIMEQUEST SystemcastWizard Lite User s Guide C122 E...

Страница 253: ...ries Reference Manual Basic Operation GUI Commands C122 E003EN 5 Window Management Instrumentation WMI setting PSA collects information on PCI cards and SCSI devices by using WMI which is installed as standard with Windows If the amount of memory and the number of internal handles that WMI uses to collect this information are insufficient because there are many LUNs such as in RAIDs change setting...

Страница 254: ...nt viewer of the application log do not change the operation that is performed when the maximum log size is reached to Do not overwrite events clear log manually Otherwise any error that occurs when the maximum log size is reached is not output to the log Do not stop the Windows service print spooler service The operating system information collection function uses the Windows Management Instrumen...

Страница 255: ...MMB 0 PCI Bus 1 Device 8 Function 0 MMB 1 PCI Bus 1 Device 0 Function 0 Use the teaming function of Intel PROSet to configure the above network adapters for duplicated communication with the management LAN For Intel PROSet teaming specify the IP addresses of the devices for the management LAN that are configured for duplicated communication 2 Configuring the two network adapters for the management...

Страница 256: ...N is changed a connection established from a remote desktop to the management LAN may be terminated In this event establish a connection by using the KVM and specifying the correct IP address For the connection to the server specify an actual server name and IP address in servername ip address A virtual IP address in the cluster cannot be specified For details on the options for mstsc you can ente...

Страница 257: ...100 VE Network Connection Properties dialog box opens Click the Teaming tab select Team with other adapters and click the New Team button Figure 4 16 Teaming tab 4 The New Team Wizard window is displayed Enter a team name the default team name is Team n and click the Next button Figure 4 17 New Team Wizard dialog box ...

Страница 258: ...adapters is displayed for teaming Select Intel R PRO 100 VE Network Connection and Intel R Pro 100 M Network Connection check boxes and click the Next button Figure 4 18 List of network adapters 6 Select Adapter Fault Tolerance from the mode list and click the Next button Figure 4 19 List of team mode ...

Страница 259: ...Teaming device is created and Team properties are displayed Click the Settings tab and confirm that the displayed adapter information is correct If the information is correct click the OK button to exit Otherwise click the Remove Team button to delete the Teaming device and start again from step 2 of this procedure Figure 4 21 Team Number 0 Properties window 9 The Intel R PRO 100 VE Network Connec...

Страница 260: ...me is the specified Team name e g Team 0 and select Properties from the right click menu 12 Select Internet Protocol TCP IP click the Properties button and specify the IP address subnet mask default gateway and other parameters in the Internet Protocol TCP IP Properties dialog box 13 Click the Configure button to display the Team properties Figure 4 22 Local Area Connection Properties dialog box ...

Страница 261: ...nation of trap sending from the partition Note z SNMP v 3 is not supported in Windows z Perform the tasks for this setting only if the setting is required z If partitions are managed by operation management software this setting is required 1 Click Control Panel Administrative Tools 2 Click Computer Management 3 In the left tree click Services and Applications Services 4 In the right pane click SN...

Страница 262: ...pt application at the trap transfer destination receives the ColdStart standard SNMP Service trap For example if the trap transfer destination is a Linux machine the following message is added to syslog when snmptrapd receives the trap and this indicates that the trap transfer destination can correctly receive such traps Aug 17 14 50 03 shaka snmptrapd 2600 2005 08 17 14 50 03 pq server fujitsu co...

Страница 263: ... received from the MMB through the following ports z TCP port used by PSA 24450 port z UDP port used for SNMP 161 port 1 Click Control Panel Windows Firewall The Windows Firewall window opens 2 Click the Exceptions tab and click the Add Port button The Add Port dialog box opens 3 Enter the port number used by PSA and click the OK button Figure 4 24 Add a Port dialog box 4 Click the Add Port button...

Страница 264: ...ork Required After Operating System Installation 5 Enter the port number used by SNMP and click the OK button Figure 4 25 Add a Port dialog box 6 In the Windows Firewall window click the OK button and this ends the setting procedure ...

Страница 265: ...and the OS is rebooted Setting procedure 1 Open the following file PSA installation folder etc opt FJSVpsa usr pnwatchdog conf Example C Program Files fujitsu FJSVpsa etc opt FJSVpsa usr pnwatchdog conf 2 Specify a key value as shown below The default is 0 Section WATCHDOG Key TIMER Set value unit seconds 0 Watchdog timer not used 1 to 6000 Watchdog timer monitoring time Remarks For the set value ...

Страница 266: ...center Note If the PEXU has been mounted use PSA 1 10 or later 1 Minor update installation 1 Save the fix program fjpsaxxxx exe to the desired folder 2 Start the fix program The following installation preparation window opens Figure 4 26 Installation preparation window 3 When the following window is displayed to indicate that the system is ready for installation click the Next button to perform in...

Страница 267: ...displayed that prompts the user to specify whether to restart the computer When this dialog box is displayed confirm that a restart at this time would cause no problem select the restart option and click the Finish button 2 Major update installation 1 Save the fix program fjpsaxxxx exe to the desired folder 2 Start the fix program The following installation preparation window opens Figure 4 29 Ins...

Страница 268: ...ious version of PSA window 4 When uninstallation is completed installation of the new version is started Figure 4 31 Update installation window 5 Specify the installation destination and click the Next button By default the new version is installed in Program Files Fujitsu To change the installation destination click the View button and specify a destination Figure 4 32 Select Features window ...

Страница 269: ...hown below is displayed Click the Finish button Figure 4 33 Installation completion window 7 If a restart is necessary a dialog box is displayed that prompts the user to specify whether to restart the computer When this dialog box is displayed confirm that a restart at this time would cause no problem select the restart option and click the Finish button ...

Страница 270: ...ion confirmation message appears Click OK to start uninstallation Figure 4 34 Confirmation message window 4 When uninstallation is completed a maintenance completion window is displayed Click Finish Figure 4 35 Maintenance completion window 5 If a restart is necessary a dialog box is displayed that prompts the user to specify whether to restart the computer When this dialog box is displayed confir...

Страница 271: ...e PSA see Chapter 4 Manual PSA Installation in the PRIMEQUEST 500A 500 400 Series Reference Manual Tools Operation Information C122 E074EN For details on installation using the PRIMEQUEST Software Installer see Section 3 3 6 1 Installation using the PRIMEQUEST Software Installer For details on installation using SystemcastWizard Lite see the PRIMEQUEST SystemcastWizard Lite User s Guide C122 E010E...

Страница 272: ...rence Manual Basic Operation GUI Commands C122 E003EN 5 Window Management Instrumentation WMI setting PSA collects information on PCI cards and SCSI devices by using WMI which is installed as standard with Windows If the amount of memory and the number of internal handles that WMI uses to collect this information are insufficient because there are many LUNs such as in RAIDs change settings to the ...

Страница 273: ... of the application log do not change the operation that is performed when the maximum log size is reached to Do not overwrite events clear log manually Otherwise any error that occurs when the maximum log size is reached is not output to the log Do not stop the Windows service print spooler service The operating system information collection function uses the Windows Management Instrumentation WM...

Страница 274: ... settings in Location on the General tab Connect the network adapter for the management LAN to MMB as follows MMB PCI Bus 1 Device 8 Function 0 2 Setting the network adapter for the management LAN Note z The Spanning Tree Protocol STP function of the switch connected to the user port management LAN of the MMB must be disabled z To make settings through a connection to a remote desktop a console se...

Страница 275: ...rtition Note z SNMP v 3 is not supported in Windows z Perform the tasks for this setting only if the setting is required z The setting is required for linkage with operation management software 1 Click Control Panel Administrative Tools 2 Click Computer Management 3 In the left tree click Services and Applications Services 4 In the right pane click SNMP Service The SNMP Service dialog box appears ...

Страница 276: ... the trap and this indicates that the trap transfer destination can correctly receive such traps Aug 17 14 50 03 shaka snmptrapd 2600 2005 08 17 14 50 03 pq server fujitsu com 192 168 0 162 via 192 168 0 162 TRAP SNMP v1 community public SNMPv2 SMI enterprises 211 1 31 1 2 100 3 Cold Start Trap 0 Uptime 0 00 00 00 4 6 3 Setting the destinations of trap and e mail sending via the MMB Note z Perform...

Страница 277: ...irewall The Windows Firewall window opens 2 Click the Exceptions tab and click the Add Port button The Add Port dialog box opens 3 Enter the port number used by PSA and click the OK button Figure 4 36 Add a Port dialog box 4 Click the Add Port button in the Windows Firewall window again The Add Port dialog box opens ...

Страница 278: ...ork Required After Operating System Installation 5 Enter the port number used by SNMP and click the OK button Figure 4 37 Add a Port dialog box 6 In the Windows Firewall window click the OK button and this ends the setting procedure ...

Страница 279: ...et and the OS is rebooted Setting procedure 1 Open the following file PSA installation folder etc opt FJSVpsa usr pnwatchdog conf Example C Program Files fujitsu FJSVpsa etc opt FJSVpsa usr pnwatchdog conf 2 Specify a key value as shown below The default is 0 Section WATCHDOG Key TIMER Set value unit seconds 0 Watchdog timer not used 1 to 6000 Watchdog timer monitoring time Remarks For the set val...

Страница 280: ...center Note If the PEXU has been mounted use PSA 1 10 or later 1 Minor update installation 1 Save the fix program fjpsaxxxx exe to the desired folder 2 Start the fix program The following installation preparation window opens Figure 4 38 Installation preparation window 3 When the following window is displayed to indicate that the system is ready for installation click the Next button to perform in...

Страница 281: ...ed that prompts the user to specify whether to restart the computer When this dialog box is displayed confirm that a restart at this time would cause no problem select the restart option and click the Finish button 2 Major update installation 1 Save the fix program fjpsaxxxx exe to the desired folder 2 Start the fix program The following installation preparation window opens Figure 4 41 Installati...

Страница 282: ...ious version of PSA window 4 When uninstallation is completed installation of the new version is started Figure 4 43 Update installation window 5 Specify the installation destination and click the Next button By default the new version is installed in Program Files Fujitsu To change the installation destination click the View button and specify a destination Figure 4 44 Select Features window ...

Страница 283: ...low is displayed Click the Finish button Figure 4 45 Installation completion window 7 If a restart is necessary a dialog box is displayed that prompts the user to specify whether to restart the computer When this dialog box is displayed confirm that a restart at this time would cause no problem select the restart option and click the Finish button ...

Страница 284: ...ion confirmation message appears Click OK to start uninstallation Figure 4 46 Confirmation message window 4 When uninstallation is completed a maintenance completion window is displayed Click Finish Figure 4 47 Maintenance completion window 5 If a restart is necessary a dialog box is displayed that prompts the user to specify whether to restart the computer When this dialog box is displayed confir...

Страница 285: ...tings that have been made see Section 4 13 1 Saving PSA setup information 4 8 1 Setting S M A R T Setting Targets of S M A R T The Self Monitoring Analysis and Reporting Technology S M A R T function for predictive monitoring can be set for hard disks This section explains how to enable or disable S M A R T for predictive detection of hard disks that support S M A R T S M A R T applies to the enti...

Страница 286: ...ernate sectors After monitoring is set the system periodically at about six hour intervals polls S M A R T on each disk to check for predictive detection z Processing performed at detection of a predictive sign of error Blinks the Fault LED on the relevant disk by repeating a cycle of four quick blinks pause Outputs information posted from S M A R T to SYSLOG and reports it REMCS e mail Procedure ...

Страница 287: ...within the specified period Boot Watchdog options other than the time out value can be set in the MMB ASR window In the MMB ASR window Boot Watchdog can be disabled in case of emergency Before making the Watchdog setting Before setting the TimeOut value for Boot Watchdog measure the standard value for a TimeOut value according to the procedure below For the actual setting value use a value that is...

Страница 288: ...n Stop rebooting and Power Off Stop rebooting or Diagnostic Interrupt assert is performed The retry count for restarting the operating system and the action to be performed are determined according to the settings of the ASR Automatic Server Restart Control window of the MMB At this time by clicking the Apply button after checking the Cancel Boot Watchdog check box in the ASR Automatic Server Rest...

Страница 289: ...C122 E001 10EN 4 103 4 8 PSA Monitoring Setup Procedure 1 Click Partition Partition x PSA Setup Watchdog The Watchdog window is displayed Figure 4 50 Watchdog window ...

Страница 290: ...monitoring is enabled Specification range 60 6000 seconds This option can be specified only when Watchdog is Enable Default 3600 Watchdog Action Select the action to be taken if recovery fails after time out occurs Select one from the drop down list No Action Do nothing Do SEL output however Reset Reset the partition Power Off Forcibly turn off the partition without executing the normal end proces...

Страница 291: ...is enabled Specification range 60 6000 seconds Note Determine the value based on the duration from when the partition power is turned on and System Progress in the Power Control window of the MMB changes to Boot to when it changes to OS Running To prevent incorrect detection Fujitsu recommends setting a sufficiently large value larger than double the above duration Also take into account the time ...

Страница 292: ...2 B009EN When Linux Red Hat is used with PRIMEQUEST the dump function that can be used depends on the Linux OS version The following briefly explains the dump environment for each Linux OS version RHEL AS4 IPF When RHEL AS4 IPF is used with PRIMEQUEST the dump function diskdump provided by the Linux distribution and the dump function sadump dedicated to PRIMEQUEST can be used Figure 4 51 shows an ...

Страница 293: ...the PRIMEQUEST 500A 500 400 Series Reference Manual Message Logs C122 E004EN If a system failure occurs in the PRIMEQUEST the user should notify the certified service engineer of the failure as an incident The certified service engineer in turn will perform investigation based on the collected dump data Before the dump data required for this investigation can be collected the initialization tasks ...

Страница 294: ...dump initial setting 4 9 3 Do these operations with the root privilege Note Regarding the environment setting from X Window System or networks such as telnet Set up the dump environment at run level 3 wherever possible without using X Window System If X Window System is used to set up the dump environment some console messages such as those related to a dump device space shortage are not displayed...

Страница 295: ...T 520A 520 420 System Design Guide C122 B009EN Remarks By using the installer on a PRIMEQUEST accessory CD ROM the dump can automatically be created The operation flow is shown below The operations require the root privilege The following explains the procedure 4 9 1 1 Creating a dump device Use the parted command to allocate a dump device area The example in this section creates the dump device d...

Страница 296: ...ce can be shared with a file system or swap partition To determine the exact size of a dump device so as to reduce disk usage when using diskdump perform the following operation The total block size is displayed in memory pages In this example an area of 262 042 x 16 384 bytes is required for the dump device Redundant dump device To guarantee that a dump can be collected on an alternate dump devic...

Страница 297: ...peration to confirm that this directory exists RHEL5 IPF Reserve a dedicated partition example dev sdb2 for the dump saving area and format it as a file system example ext3 Perform the following operation to confirm that this directory has been created correctly To ensure that destruction does not occur during operation be sure not to mount the dump saving area For Linux Red Hat prepare the follow...

Страница 298: ...d command displays the size of the entire disk partition including the management area used by the ext3 file system Therefore to check the size of the necessary dump saving area divide the displayed size value by 1 1 to determine the size of the area in which an ext3 file can be created If a dump is saved normally a file called vmcore is created If the saving area runs short of free space an incom...

Страница 299: ...eration requires the root privilege The following explains the procedure 1 Setting a dump device Use a text editor such as vi to add the following definition to the diskdump definition etc sysconfig diskdump Note Specify the name of a compatible device as the device name Remarks When specifying a dump device list including at least one redundant device use a colon to delimit adjacent device names ...

Страница 300: ...vi to add the following line to the diskdump module parameter etc modprobe conf Use the file command in the manner shown below to confirm the compression of the dump area If the dump area is not compressed As shown in the example below a file is displayed in ELF format If the dump area is compressed If the dump file type has been reset while the diskdump service is active the system needs to be re...

Страница 301: ...g command If 1 is displayed it indicates that the setting has been validated For the system parameter check tool see Appendix A 5 System Parameter Check Tool z When the system parameter check tool is not installed Correct the kernel sysrq value in the etc sysctl conf file to validate the setting Enter the following command If 1 is displayed assumed that the setting is reflected 5 Setting a dump se...

Страница 302: ...these messages 2 Checking dump collection If the system actually crashes the dump may not be collected because of an area shortage To prevent that check whether the crash dump is actually collected Note If the crash dump is forcibly collected the system is forced to crash Before checking the dump collection stop any important applications Unnecessary file systems should also be demounted 1 Manuall...

Страница 303: ...stem To reset the system click Partition Power Control on the MMB Web UI specify Reset as the status and click the Apply button 4 Confirm that a dump has been collected Perform the following two procedures Confirm that a directory of var crash 127 0 0 1 date and time has been created To check whether a dump has been collected check whether a vmcore file has been created under the above directory 5...

Страница 304: ...nstalling kexec tools The package kexec tools which is required for kdump may not automatically be installed depending on how RHEL5 IPF is installed When necessary therefore install it manually as follows kernel debuginfo and kernel debuginfo common may also need to be installed When necessary install them as follows rpm q kexec tools rpm ivh kexec tools version level to be installed el5 ia64 rpm ...

Страница 305: ...formed after dump collection If sadump has been applied the sadump definition is followed after kdump collection and therefore the values set here are ignored 3 Specify this to use the compressed dump function Omit it if the function is not used The compressed dump function can reduce the dump collection area but may take more time for dump collection Perform performance verification sufficiently ...

Страница 306: ...owing to check whether the dump service has been set correctly The settings are displayed as shown below 4 9 3 5 Setting the kernel parameter Specify the following with the kernel parameter append in boot efi efi redhat elilo conf 4 9 3 6 Rebooting the system Enter the following to reboot the system chkconfig kdump on chkconfig list kdump kdump 0 off 1 off 2 on 3 on 4 on 5 on 6 off append crashker...

Страница 307: ...unted 1 Manually collecting a dump Select Partition Power Control from the MMB Web UI to set the INIT control and then click the Apply button to start dump collection 2 Confirming that dump collection is complete Confirm that dump collection has been completed with the following message displayed on the console Note When the dump has been collected successfully the message shown in the example tha...

Страница 308: ... Note If UTC false is set in etc sysconfig clock the displayed date time is 9 hours added to the date time of dump collection Be careful not to mistake it for the date time of dump collection Confirm that the dump is collected or the size of vmcore under the above directory is more or less the same as the estimated size of the dump file Because the dump saving area is not mounted with the operatin...

Страница 309: ...n z Setting a memory dump file and paging file 4 10 1 z Early troubleshooting DSNAP 4 10 2 4 10 1 Setting a memory dump file and paging file This section explains how to set a memory dump file and paging file The memory dump file is used to save debug information when a STOP error fatal system error occurs in the system After the operating system and applications used for operation are installed m...

Страница 310: ...verwritten The default setting can be changed so that an existing file is not overwritten However note that no new file would be created unlike in a minimum memory dump Notes Select the setting mode appropriate for system operation by considering the following If the PRIMEQUEST Software Installer is executed the mode is automatically set to kernel memory dump Because a kernel memory dump does not ...

Страница 311: ...rt the system For details on the dump file save path and overwrite settings see Setting a kernel memory dump minimum memory dump Setting a kernel memory dump minimum memory dump Set the memory dump file as follows 1 Log on to the server with the administrator privilege 2 Check the amount of free space on the drive on which the memory dump file is to be stored For details see Section 4 10 1 4 Setti...

Страница 312: ...mory dump file is saved If the Overwrite any existing file check box is selected for kernel memory dump debug information is always written to the specified file Small memory dump 64 KB or 128 KB Minimum information is logged in the memory dump file In the Small Dump Directory field specify the full path of the directory used to store small dumps Every time an unrecoverable error occurs a new file...

Страница 313: ...ded To implement a dump specify INIT for the target partition by selecting Partition Power Control from the MMB Web UI For details see Chapter 5 MMB Web UI in the PRIMEQUEST 580A 540A 520A 500 400 Series Reference Manual Basic Operation GUI Commands C122 E003EN 4 10 1 4 Setting the paging file Set the paging file by following the procedure below Unless otherwise instructed use the values that are ...

Страница 314: ...4 128 C122 E001 10EN CHAPTER 4 Work Required After Operating System Installation 4 Click the Advanced tab Figure 4 54 Performance Options dialog box ...

Страница 315: ...e for selected drive 7 Select the Custom size option button and enter a value in Initial size To find out the minimum value follow the procedure below 1 Enter the minimum value in the Initial size MB field in the Custom size section if the Virtual Memory dialog box shown in Figure 4 55 is displayed this value is 16 MB which is the value of Minimum allowed in the Total paging file size for all driv...

Страница 316: ... a value greater than Initial size 9 Save the settings Click Set in Paging file size for selected drive The settings are saved and displayed under Paging File Size of Drive 10 Click OK to close the Virtual Memory dialog box 11 Click OK to close the Performance Options dialog box 12 Click OK to close the System Property dialog box 13 Reboot the system The settings are validated after the system reb...

Страница 317: ...tigative data when a problem occurs in Windows OS If a problem occurs in your system your Fujitsu certified engineer uses this software to correctly find out your system software configuration and setting states and conduct smooth examinations of processes z Installation method See Section 3 3 6 High Reliability Tools z Usage Refer to OS Installation Drive DSNAP README_EN TXT file ...

Страница 318: ...the clock within a certain range of accuracy 4 11 1 NTP operation on PRIMEQUEST This section describes how to correct time for each partition using NTP on the PRIMEQUEST The PRIMEQUEST provides NTP client and server functions on the MMB The MMB NTP client function allows you to specify up to three individual NTP servers Each partition uses the NTP server function on the MMB to adjust the time on t...

Страница 319: ... are NTP servers using very high precision clocks for connections to the Internet or intranets GSWB is mounted only in PRIMEQUEST 580A 540A 540 540 480 440 NTP Client NTP Server MMB MMB NTP Client GSWB GSWB GSWB Partition 0 NTP Client PRIMEQUEST Management LAN Partition 1 NTP Client NTP Server 1 NTP Server 2 NTP Server 3 NTP Server 4 NTP Server 5 System System Clock Clock System Clock System Syste...

Страница 320: ...in one cabinet use the following setting but it is not a typical configuration z NTP Enable z NTP Server 1 to NTP Server 3 0 0 0 0 1 Click Network Configuration Date Time The Date Time window appears Figure 4 58 Date Time window example 2 Specify NTP as Enable 3 Specify the IP addresses of the other NTP servers NTP Server1 Specify the primary NTP server NTP Server2 Specify the secondary NTP server...

Страница 321: ...C122 E001 10EN 4 135 4 11 NTP Client Setup 5 After several minutes have passed click the Refresh button and confirm that the correct time is displayed ...

Страница 322: ...up script NTP setup on a partition To set up NTP on a partition running Linux perform the following steps 1 Set an NTP server in the ntp configuration file etc ntp conf as follows Figure 4 59 NTP server IP address setting example Because no special options are required for communication between the MMB and a partition the above setting is all that you need to use ntpd When the MMB is used as an NT...

Страница 323: ... Administrator account 2 Click Control Panel Date and Time The Date and Time Property dialog box appears 3 Click the Internet Time tab 4 Specify the MMB virtual IP address in the Server box and then click OK to close the box 5 Click the Internet Time tab again from the Date and Time Property dialog box and then click Update Now During normal communication with the NTP server the message shown in F...

Страница 324: ...t log 4 An MMB physical IP address is used in communication for time synchronization with an external NTP server In case a setting such as a firewall security setting needs to be changed to enable communication note that communication needs to be enabled not only with the MMB virtual IP address Virtual IP address but also with the corresponding physical IP addresses MMB 0 IP address and MMB 1 IP a...

Страница 325: ...omatically synchronized with the NTP server of the domain controller In such cases the Internet Time tab is not displayed as shown in the figure below Every partition in an MSCS cluster environment must always belong to a domain and the time of the partition also is automatically synchronized with the NTP server of the domain controller Figure 4 61 Date and Time Properties dialog box in time synch...

Страница 326: ... contained in a partition in which the Linux OS is installed Two Linux backup methods are available z Using the standard OS utilities z Using SystemcastWizard Lite The Linux OS system volume backup procedure as described below uses the standard OS utilities in each of the following two cases When PRIMECLUSTER GDS is not used When PRIMECLUSTER GDS is used Note Prepare a single unit such as a tape u...

Страница 327: ...d disk configurations of the objective system Note The information displayed at this time would be required for recovery if the disk were to fail Record the command output to ensure that it can be read at the time of recovery 1 Check the system configuration 1 Check IDE and SCSI card types and IRQ and I O port operating status or 2 Check driver file names 3 Check device names device types and majo...

Страница 328: ...displayed at the backup time change the display unit to a smaller measurement unit before executing the print subcommand and record it for partition reconfiguration In the above example unit s is used for the display unit s for sectors 3 Check file system label names If a device mounted in boot efi is specified an error occurs This error occurs because the file system is different That does not ca...

Страница 329: ...C122 E001 10EN 4 143 4 12 OS Backup Settings Backup Perform the backup in the following procedure The following explains each step Switch to single user mode Check file system matching Back up to media ...

Страница 330: ...t the name of the system to be started such as Red Hat Enterprise Linux Note Advance settings are required to start the EFI boot manager menu For the setting procedure see Section 5 3 8 2 Boot Control window in the PRIMEQUEST 580A 540A 520A 500 400 Series Reference Manual Basic Operation GUI Commands C122 E003EN 2 Enter the command shown below following the ELILO boot prompt When a KVM console is ...

Страница 331: ... Do not execute the e2fsck command if the umount command produces an error If the e2fsck command is executed with the file system mounted the selected volume may be damaged z For root 1 Remount the file system in Read Only mode 2 Check the matching of the file system 3 Remount the file in normal state Note Do not execute the e2fsck command if the mounting in Read Only mode fails If the e2fsck comm...

Страница 332: ...ion because the default block sizes of the tape units may be different Execute backup and restoration based on the same block size Restoration fails if the block size used for restoration differs from that used for backup z Using a locally connected tape unit 1 Prepare a tape unit See mt command manuals for details Display status information on the tape unit Rewind tape 2 Back up For location othe...

Страница 333: ...ewind tape Enter the password in response to the password prompt 4 Back up Use the ssh command for the backup operation For a file system other than boot efi Back up with the dump command Enter the password in response to the password prompt For boot efi Back up with the tar command Enter the password in response to the password prompt etc rc d init d network start ifconfig eth0 xxx xxx xxx xxx ne...

Страница 334: ...s Remarks See the PRIMECLUSTER Global Disk Services Handbook for details 4 12 2 Windows backup Use SystemcastWizard Lite to back up a Windows partition For details see the PRIMEQUEST SystemcastWizard Lite User s Guide C122 E010EN Stop all running applications Switch to single user mode Investigate the device special name of the file system Back up the file system data to media ...

Страница 335: ... to 100 data files When 100 files are exceeded the least recent file is deleted and a new file is saved Exported data remains saved unless the maximum number is exceeded or it is deleted intentionally 4 13 1 1 Listing exported files This section explains what can be done from a listing of files The screen lists the files currently exported in order with the most recent on top The following types o...

Страница 336: ...ime To delete all exported files click the Delete All button To delete a specific file select the radio button of the target file and click the Delete button Only one file can be selected at a time For the subsequent operation see Section 4 13 1 2 Saving to a CSV format file Table 4 8 Displayed and setting items in the Export window Item Description Exported Date Select the radio button of the fil...

Страница 337: ...dow is restored Remarks The keyword is a supplementary phrase assigned to exported data Enter it in up to 50 characters The keyword field can be left blank if you do not want to enter a keyword If the export fails the Export Failure Notice dialog box appears Click the Return button The Export List window is restored with the latest list displayed Figure 4 63 Export window example 2 If export faile...

Страница 338: ...uration window appears Figure 4 64 Backup EFI Configuration window example 2 Select the radio button of the partition for which configuration information is to be backed up and click the Backup button 3 The storage destination dialog box appears Select the storage path and click the OK button The default name of the EFI configuration file to be backed up is as follows 4 Click the OK button The dow...

Страница 339: ...nsidering the operation conditions specify the required security settings It is recommended to back up the setup information after completing the following setup tasks For backing up the settings made here see Section 2 6 Saving Configuration Information z Access control setting 5 1 1 z System SNMP setting 5 1 2 z Specifying SSH parameters 5 1 3 z Specifying HTTPS parameters 5 1 4 ...

Страница 340: ...re 1 Click Network Configuration Access Control The Access Control window is displayed Figure 5 1 Access Control window example 2 Use a radio button to select a filter to be edited Table 5 1 Displayed and setting items in the Access Control window Item Description Protocol Displays protocols subject to IP filtering HTTP HTTPS Telnet SSH SNMP Access Control Displays setting for enabling disabling a...

Страница 341: ...ick the Add Filter button in the Access Control window To edit the filter click the Edit Filter button For addition the Add Filter window is displayed For editing the Edit Filter window is displayed The following shows a display example of the Edit Filter window Figure 5 2 Edit Filter window example ...

Страница 342: ...ncel the removal click the Cancel button Item Description Protocol Sets a protocol subject to IP filtering Select one of the following from the pull down menu HTTP HTTPS Telnet SSH SNMP Access Control Use the Enable and Disable radio buttons to specify whether to implement access control If Disable is selected access to the protocol selected above is enabled for all IP addresses In this case entry...

Страница 343: ...anagement software if an error occurs during operation To notify the linked management software specify the report destination Set the following four z Enabling SNMP z Setting SNMP detail z Setting an SNMP trap send destination z SNMP v3 setting Enabling SNMP Procedure 1 Click Network Configuration Network Protocols The Network Protocols window is displayed Figure 5 3 Network Protocols window exam...

Страница 344: ...em Description SNMP SNMP Agent Enables or disables SNMP Agent Default Disable Agent Port Sets a port to be used for SNMP Agent Port numbers that can be set are 161 and 1 024 to 65 535 Default 161 SNMP Trap Enables or disable SNMP Trap Default Disable Trap Port Set a port to be used for SNMP Trap Port numbers that can be set are 162 and 1 024 to 65 535 Default 162 ...

Страница 345: ...can be set Enter a community to be set access enabled IP address SNMP version access authority and certification information To delete the items clear the Community and IP address items Table 5 4 Displayed and setting items in the SNMP Community window Item Description System Information System Name Displays a system name of the PRIMEQUEST set in the System Information window Set the name in the S...

Страница 346: ... end of the string en size space Community Community Sets an SNMP Community string Remarks Any of the following characters can be used 0 9 a z A Z en size space _ However the following character cannot be used at the beginning of the string IP Address MASK Set an access enabled IP address or network address SNMP Version Sets an SNMP version 1 2 or 3 Access Specifies whether to enable reading or re...

Страница 347: ... 5 1 Security Settings 3 Click the Apply button Setting an SNMP trap send destination Procedure 1 Click Network Configuration SNMP Configuration Trap The SNMP Trap window is displayed Figure 5 5 SNMP Trap window example ...

Страница 348: ...ress of the trap transfer destination SNMP Version Used to select an SNMP version 1 A version 1 SNMP trap is sent 2 A version 2 SNMP trap is sent 3 A version 3 SNMP trap is sent Auth Used to select an authentication level noauth Disables authentication and encryption based on a password enables authentication based on a user name auth Enables authentication based on a password but disables encrypt...

Страница 349: ...ccess must be completely set again from the beginning To validate the set user temporarily stop the SNMP daemon and then restart it Therefore if the Apply button is clicked here the SNMP service is temporarily stopped Procedure 1 Click Network Configuration SNMP Configuration SNMP v3 Configuration The SNMP v3 Configuration window is displayed Figure 5 6 SNMP v3 Configuration window example ...

Страница 350: ...size space The following character cannot be used at the end of the string en size space User User Name Specifies a user name Selecting the check box of the target user enables input of a user name Remarks Any of the following characters can be used 0 9 a z A Z en size space _ However the following character cannot be used at the beginning of the string Auth Type Select the authentication type MD5...

Страница 351: ... The Network Protocols window is displayed Figure 5 7 Network Protocols window example 2 Specify the items related to SSH Table 5 7 Setting items of SSH 3 Click the Apply button Item Description SSH SSH Sets Enable Disable of SSH Default Disable SSH Port Sets a port to be used for SSH Default 22 Timeout Sets a time interval allotted for entering data with SSH connected before the connection is cut...

Страница 352: ...ficate must have been registered If the user attempts to enable HTTPS without the certificate being registered an error is displayed You do not need to perform this step if it has already been performed by the certified service engineer for test program execution Procedure 1 Click Network Configuration Network Protocols The Network Protocols window is displayed Figure 5 8 Network Protocols window ...

Страница 353: ...f HTTPS 3 Click the Apply button Item Description Web HTTP HTTPS HTTPS Sets Enable Disable of HTTPS Default Disable HTTPS Port Sets a port number to be used for HTTPS Default 432 HTTP HTTPS Timeout Sets a time interval allotted for entering data with HTTP HTTPS connected before the connection is cut off Default 600 seconds ...

Страница 354: ......

Страница 355: ... Initialization 1 If the optional product GSWB is implemented in PRIMEQUEST 580A 540A 580 540 480 440 you need to initialize the GSWB Perform initialization by following the instructions in the PRIMEQUEST GSWB User s Manual C122 E028EN ...

Страница 356: ......

Страница 357: ... Software configuration information collection Y 1 Y 1 SCSI related software programs 4 Driver Driver Y Y Y Y 5 Fusion MPT EFI appl F W update tool Y 6 Fusion MPT management tool CIMS Browser Y Y Broadcom LAN related software programs 7 Driver Driver Y Y 8 BCM EFI appl Y 9 BACS Win VLAN aggregation etc Y Intel LAN related software programs 10 Driver Driver Y Y Y 11 Intel PROSet Win VLAN AFT ALB et...

Страница 358: ...lation tool bundled software Y Y 23 DSNAP Runs OS level commands to collect basic information on Windows OS Y 24 PRIMEQUEST Software Installer Tool for installing the accompanying software Y 25 System Parameter Check Tool Checks the environment variables arguments required for OS operation being set by the user Y 26 System data output tool fjsnap Runs on an OS to collect the information required f...

Страница 359: ...is chapter describes overview of these bundled versions and installation and operation of SystemcastWizard Lite z Installation Support Tool A 2 z Bundled Software Package Installer A 3 z DSNAP A 4 z System Parameter Check Tool A 5 z System Data Output Tool fjsnap A 6 z SystemcastWizard Lite A 7 z Installation Support Tool for Windows A 8 z Software Support Guide A 9 ...

Страница 360: ... made in advance in the config file created by the installation support tool on a Windows PC to facilitate work for this OS installation The bundled software package installer facilitates installation of supplied software For details see the PRIMEQUEST Installation Support Tool User s Guide Red Hat C122 E005EN and the PRIMEQUEST Installation Support Tool User s Guide SUSE C122 E047EN A 3 Bundled S...

Страница 361: ...meters which are very likely to be changed in the Linux kernel environment may prevent normal operation of the Linux system System Parameter Check Tool detects and reports these settings System Parameter Check Tool supports the following Linux OS z Red Hat Enterprise Linux AS v 4 for Itanium z Red Hat Enterprise Linux 5 for Intel Itanium System Parameter Check Tool provides commands that check and...

Страница 362: ...0 types 1 000 files of hardware software configuration information environment setups operation information and the logs required for troubleshooting and then compresses and outputs them into a file An outline of system information collection by fjsnap is shown below Figure A 1 Outline of system information collection by fjsnap For further information on fjsnap see the PRIMEQUEST 500A 500 400 Seri...

Страница 363: ...w installation of an OS through a network All end to end installation processes are performed automatically based on the setup information that is specified in advance The required installation time and workload can be reduced because a system with the same configuration can be constructed any number of times and an OS can be installed in multiple partitions at the same time Backup restore This fu...

Страница 364: ...console deployment console on this management terminal instructions can be issued to the PRIMEQUEST for remote OS setup and backup restore Note that the DHCP function 1 is started via the network Note also that an FTP server is required to remotely set up a Linux OS 1 SystemcastWizard Lite contains a simple DHCP server PRIMEQUEST Contents of the OS CD setup information SystemcastWizard Disk image ...

Страница 365: ... further information see the manual for PRIMEQUEST SystemcastWizard Lite User s Guide C122 E010EN A 7 4 How to use the SystemcastWizard Lite From the Start menu on the management terminal where you installed SystemcastWizard Lite click Programs SystemcastWizard Lite Deployment Console This starts the deployment console Figure A 3 Starting the deployment console Window components The deployment con...

Страница 366: ...below 1 Select the target partition from the Partitions View 2 From the menu select the task you want to perform remote OS setup or backup restore A dialog box appears 3 Follow the instructions displayed on the dialog box to set up and run the software You can see the progress status and execution results on the deployment console because that information is displayed in the Details View For detai...

Страница 367: ...n the following path on the PRIMEQUEST Drivers CD for Microsoft Windows Server 2003 C122 E024 E Tools General IST manual where the CD ROM drive is Drive E A 9 Software Support Guide Software Support Guide is a group of programs that can collectively gather information on software errors in Windows in a prompt and accurate manner Fujitsu certified engineers use Software Support Guide to learn how y...

Страница 368: ...l name Information collected QSS Quick Support System Registries event logs system file list Watson log minidumps and MSCS cluster log User mode Process Dumper Application snapshot dumps Desktop Heap Monitor Information on the size of the desktop heap which is a system resource ETW Event Trace for Windows OS standard trace function Process thread disk network trace can be used ETW must be started ...

Страница 369: ...Connecting a General purpose PC This section describes the procedure for connecting a general purpose PC to the PRIMEQUEST main unit 1 Connect the COM port on the general purpose PC to the RS 232C external interface of the MMB with an RS 232C cross cable 1 in Figure B 1 2 Connect the LAN port on the general purpose PC to the LAN maintenance external interface of the MMB with a LAN cable 2 in Figur...

Страница 370: ...I 1 PCI 3 PCI 2 PCI 0 BMM 0 BMM 1 HDD 3 HDD 2 HDD 1 HDD 0 HDD 3 HDD 2 HDD 1 HDD 0 HDD 3 HDD 2 HDD 1 HDD 0 HDD 3 HDD 2 HDD 1 HDD 0 MMB 1 GSWB 0 GTHB 0 GSWB 1 GTHB 1 Rear view PRIMEQUEST 580A 540A 580 540 480 440 Rear view PRIMEQUEST 520A 520 420 BP SB 0 MMB IOX ACS FAN_C 1 FAN for SB IOB P C I 7 P C I 6 P C I 5 P C I 4 P C I 3 P C I 2 P C I 1 P C I 0 B M M 0 B M M 1 G S R B 1 1 1 PCI 2 and PCI 3 ca...

Страница 371: ...re settings External interface Quantity Remarks RS 232C 1 Used by a Fujitsu certified service engineer to set up the unit It is not used in normal operation LAN 100Base TX 3 User Used for a console connection Maintenance LOCAL Dedicated for use by a Fujitsu certified service engineer REMOTE REMCS port Setting item Value Bits per second 19200 Data bits 8 Parity None Stop bit 1 Flow control Not appl...

Страница 372: ...ring that consists of at least eight characters and cannot easily be guessed If the entered password is inadequate the system prompts you to enter another password 5 Set up the MMB network Specify the IP address by using the following command Example Setting 192 168 0 10 for the IP address 255 255 255 0 for the netmask and 192 168 0 1 for the gateway 6 Enter the set http enable command to enable h...

Страница 373: ...I uses JavaScript JavaScript must be enabled in the browser settings on the general purpose PC used z Because the MMB Web UI downloads items downloading must be enabled in the browser settings on the general purpose PC used 1 Start the browser and enter the following URL http nodename adminport nodename IP address of the MMB adminport Port number assigned to the MMB management port default 8081 Ex...

Страница 374: ...in Section B 2 Initializing the MMB Remarks Closing this Web UI window To close this Web UI window click Logout on the navigation bar indicated by e Figure B 2 Web UI Frame Information window a Displayed FUJITSU logo b Information area c Indication of the Active MMB d Maintenance status display e Navigation bar g Bar displaying the submenu hierarchy h Content display area f Submenu ...

Страница 375: ...olling the main power This section explains powering on and off through control of the main power The circuit breakers of the PRIMEQUEST 580A 540A 580 540 480 440 are the main power switches on the main unit They also work as circuit protectors that protect the main unit by detecting overcurrents Note FAN_E 0 and FAN_E 1 of the PRIMEQUEST 520A 520 420 series machine rotate not only when the system...

Страница 376: ... switching it on again If the circuit breaker is switched off because an overcurrent was detected a problem such as a short circuit occurred in the main unit If the circuit breaker is switched on again under this condition the circuit breaker on the distribution panel may be switched off and a burnout may occur in the main unit To prevent this problem do not switch on the circuit breaker again and...

Страница 377: ... the unit configuration Figure C 2 shows an example of the Extended Power Cabinet with a PSU expansion installed 3 When an Extended I O Cabinet is connected turn on the circuit breakers of the Extended I O Cabinet Open the front door of the Extended I O Cabinet and set all the switches used in the power distribution box to the 1 side Remarks The type of power distribution box and circuit breaker i...

Страница 378: ...C 4 C122 E001 10EN Appendix C Power Control Figure C 3 Circuit breaker locations Extended I O Cabinet Circuit breaker ...

Страница 379: ...ched off because an overcurrent was detected a problem such as a short circuit occurred in the main unit If the circuit breaker is switched on again under this condition the circuit breaker on the distribution panel may be switched off and a burnout may occur in the main unit To prevent this problem do not switch on the circuit breaker again and call a certified service engineer Power on procedure...

Страница 380: ...the unit configuration See Figure C 2 Figure C 2 shows an example of the PRIMEQUEST 580A 580 480 with a PSU expansion installed 4 Turn off the circuit breakers of the main unit Open the rear door of the main unit and set all the circuit breakers on the upper part of the cabinet to the O side Note The number of switches depends on the mode of power feed to the main unit See Figure C 2 Figure C 2 sh...

Страница 381: ...tion box to the 0 side Remarks The type of power distribution box and circuit breaker in the Extended I O Cabinet depends on the region in which the cabinet is used See Figure C 3 Especially in Europe the power distribution box in the Extended I O Cabinet does not have circuit breakers For this cabinet therefore turn off the circuit breakers on the power distribution board to which the input power...

Страница 382: ... LED of the MMB Ready LED of the MMB Active LED of the MMB 3 Disconnect the power cable from the power distribution box Data destruction When power to the main processing unit is turned off in an operation from the MMB only the following LEDs of the OPL and the MMB stay lit z MMB Ready LED of the OPL z Power LED of the MMB z Ready LED of the MMB z Active LED of the MMB Before turning off the main ...

Страница 383: ... MMB Web UI window is displayed 3 Click System System Power Control from the MMB menu The System Power Control window is displayed Figure C 5 System Power Control window 4 Click Power On all partition s or Power On the Chassis only only for the PRIMEQUEST 580A 540A 580 540 480 440 and click the Apply button System power is turned on Remarks If Power On all partition s is selected while only cabine...

Страница 384: ...e MMB Web UI window is displayed 2 Click System System Power Control from the MMB menu The System Power Control window is displayed Item Description Power On all partition s Power to every partition is turned on If this item is selected while only cabinet power is on power to every partition is turned on Power On the Chassis only PRIMEQUEST 580A 540A 580 540 480 440 only Power to components other ...

Страница 385: ...tem Power Control window 3 Click Power Off the Chassis all partition s will be automatically shutdown or Force Power Off and click the Apply button System power is turned off Remarks If Force Power Off is selected power is turned off without shutting down any OS running a partition ...

Страница 386: ...0 Series Reference Manual Basic Operation GUI Commands C122 E003EN Remarks The procedures described below show sample screenshots of windows displayed for the PRIMEQUEST 580A 540A 580 540 480 440 Procedure 1 Click System System Power Control from the MMB menu The System Power Control window is displayed Figure C 7 System Power Control window 2 Select a power control mode and click the Apply button...

Страница 387: ...his item is selected while only cabinet power is on power to every partition is turned on Power On the Chassis only only for the PRIMEQUEST 580A 540A 580 540 480 440 Power to components other than the SB and IO Unit is turned on This power on operation includes the GSWB Power Off the Chassis all partition s will be automatically shut down Every partition is shut down and cabinet power is turned of...

Страница 388: ...rom the MMB menu The Power Control window is displayed This window displays only the partitions that are bootable with SBs and IO Units assigned Figure C 8 Power Control window The column shows partitions numbers For details about the Power Control window see Part III MMB in the PRIMEQUEST 580A 540A 520A 500 400 Series Reference Manual Basic Operation GUI Commands C122 E003EN 3 To turn on a partit...

Страница 389: ...y occur Failed The partition failed Power Status The partition power status is displayed as follows On Power is on Standby The partition is in the standby state System Progress The progress of a partition is displayed Power Off Partition power is off Power On In Progress The partition is in power on sequence Reset The partition is reset POST XXXXh Indicates that the partition has started POST Code...

Страница 390: ...eration simply turns off power without shutting down the OS Power Cycle Forcibly turns off the partition and turns it on again Reset Resets the partition INIT Issues the INIT interrupt to the partition Force Power Off Forcibly turns off the partition Not specify Takes no action for the partition Notes Executing INIT forcibly terminates applications running in the partition Before executing INIT st...

Страница 391: ... OS or application manuals Remarks After the cabinet power is turned off it cannot be turned on again for a certain period of time During this period Power Control is grayed out and cannot be selected Under Maintenance This indicates whether a partition is under maintenance Maintenance The partition is under maintenance hyphen The partition is not under maintenance Partitions under maintenance are...

Страница 392: ...rs contact a Fujitsu certified service engineer Also do not execute Reset or Force Power Off for a partition until the problem is removed Power off Reset or Force Power Off is executed for a partition or a shutdown is executed from the operating system and as a result Error is displayed for Status in the MMB Web UI window information frame Furthermore an attempt to display the status of each compo...

Страница 393: ...e OS When the Power Off operation is selected and the OS supports ACPI the OS can be shut down and the power to a partition can be turned off by the power off operation described above However if the OS does not support ACPI this operation turns the power off without shutting the OS down Even if the OS supports ACPI power may not be turned off if an application running under the OS does not suppor...

Страница 394: ......

Страница 395: ...e product as an example but the basic unit settings are the same for other manufacturer s SAN storage units if they are used z PRIMEQUEST z Fibre Channel FC card z SAN storage unit ETERNUS z FC switch as needed for configuration z PC used to configure the SAN storage unit ETERNUS and FC switch The PC can also be used as the MMB console or other such console z Windows Server 2003 Enterprise Edition...

Страница 396: ...cording to the configuration design The Fibre Channel EFI driver must be configured z Set up SAN storage and FC switches Mount connect configure and tune the SAN storage units and FC switches according to the connection diagram prepared during environment design D 3 Design An important part of designing the SAN boot environment is to design a topology connection configuration based on the business...

Страница 397: ...an example of SAN boot in the 2 path configuration Figure D 1 SAN boot configuration example 1 2 path configuration 2 Recommended 4 path configuration Figure D 2 shows an example of SAN boot in the 4 path configuration Figure D 2 SAN boot configuration example 2 4 path configuration ...

Страница 398: ...PN for zoning When FC switches are used zoning must be set up according to the system configuration If zoning is specified manually either a specified port or WWPN can be selected However for simplicity in the event of a failure set 1 to 1 WWPN If a specified port is used and a CA host FC switch port on an ETERNUS unit fails zoning must be set up again z Do not share the system disk The system dis...

Страница 399: ...n which HBA access is enabled is already set up such as when the ETERNUS unit is connected directly to the HBA the HBA WWPN required for this setting can be specified from the list displayed by ETERNUS setup software Note I O processing across the ETERNUS unit must have been executed at least once from the HBA z In other cases obtain information from the EFI console of the server containing the HB...

Страница 400: ...ion lists the WWPNs assigned to CAs For details see the ETERNUS manuals For details on how to obtain the WWPN of the HBA see Section D 4 4 Configuring the EFI driver 2 Basic switch settings The IP addresses in the LAN subnet masks and the gateway addresses of the switch and PC must be set These switch settings can be made from the operation panel or through the serial port For details see the refe...

Страница 401: ...rn on power to the partition The EFI Boot Manager window is displayed on the console 2 Start EFI Shell Select EFI Shell Built in and press the Enter key EFI Shell starts 3 List drivers After EFI Shell starts enter the following and press the Enter key A list of drivers is displayed as shown below Find the line with Emulex SCSI Pass Thru Driver displayed in the DRIVER NAME column and record its val...

Страница 402: ...Chapter 4 Physical Positions and Bus Numbers in the PRIMEQUEST 500A 500 400 Series Reference Manual Tool Operation Information C122 E074EN PRIMEQUEST 580A 540A 580 540 480 440 PRIMEQUEST 580A 540A 580 540 480 440 PCI Slot Physical Positions and Bus Numbers PRIMEQUEST 520A 520 420 PRIMEQUEST 520A 520 420 PCI Slot Physical Positions and Bus Numbers Shell drivers b T D D Y C I R P F A V VERSION E G G...

Страница 403: ...in step 6 Enter y in the displayed dialog box to initialize the HBA settings Note This operation is not required in the system state immediately following shipment from the factory Emulex FC EFI Bios Utility Ver 3 10a6 001 LP10k PCI X 133MHz Bus 49 Dev 01 Func 00 HBA Status Ready Boot Bios Disabled EFI Boot TE3 10A6 Firmware TS1 91A1 1 Setup Utility 2 Firmware Update Emulex FC EFI Bios Setup Utili...

Страница 404: ...ries are empty in the initial state 13 Select 01 DID 0000000 WWN 00000000 00000000 and press the Enter key The following menu is displayed EFI Bios Boot Option is Currently DISABLED Disabled default Enabled 1 Device Path Selection 2 Maximum Luns Target 3 Boot Target Scan 4 Configure Boot Devices 5 Delay Device Dicovery 01 DID 000000 WWN 00000000 00000000 02 DID 000000 WWN 00000000 00000000 03 DID ...

Страница 405: ...he Enter key The following list is displayed Here are targets numbers 001 thru 001 001 DID 0000EF WWN 202C00E0 00CB0815 Here are Luns numbers 0001 thru 0001 0001 Mode Peripheral dev LUN 0000 Selected Boot Device 001 DID 0000EF WWN 202C00E0 00CB0815 Mode Per LUN 0000 1 Boot this device via WWN 2 Boot this device via DID 01 DID 000000 WWN 202C00E0 00CB0815 Mode Per LUN 0000 02 DID 000000 WWN 0000000...

Страница 406: ...FI Boot Manager window is displayed on the console 2 Start EFI Shell Select EFI Shell Built in and press the Enter key EFI Shell starts 3 List drivers After EFI Shell starts enter the following and press the Enter key A list of drivers is displayed as shown below Find the line with Emulex SCSI Pass Thru Driver displayed in the DRIVER NAME column and record its value in the DRV column In the follow...

Страница 407: ...hysical Positions and Bus Numbers in the PRIMEQUEST 500A 500 400 Series Reference Manual Tool Operation Information C122 E074EN PRIMEQUEST 580A 540A 580 540 480 440 PRIMEQUEST 580A 540A 580 540 480 440 PCI Slot Physical Positions and Bus Numbers PRIMEQUEST 520A 520 420 PRIMEQUEST 520A 520 420 PCI Slot Physical Positions and Bus Numbers Shell drivers b T D D Y C I R P F A V VERSION E G G D C DRIVER...

Страница 408: ... displayed in step 6 Enter y in the displayed dialog box to initialize the HBA settings Note This operation is not required in the system state immediately following shipment from the factory Emulex FC EFI Bios Utility Ver 3 11a4 001 LP11002 PCI X 133MHz Seg 00 Bus 49 Dev 01 Func 01 HBA Status Ready Boot Bios Disabled EFI Boot BE3 11A4 Firmware BS2 10A7 1 Setup Utility 2 Firmware Update Emulex FC ...

Страница 409: ...e initial state 13 Select 01 DID 0000000 WWN 00000000 00000000 and press the Enter key The following menu is displayed EFI Bios Boot Option is Currently DISABLED Disabled default Enabled 1 Device Path Selection 2 Maximum Luns Target 3 Boot Target Scan 4 Configure Boot Devices 5 Delay Device Dicovery 01 DID 000000 WWN 00000000 00000000 02 DID 000000 WWN 00000000 00000000 03 DID 000000 WWN 00000000 ...

Страница 410: ... via WWN and press the Enter key The following list is displayed Here are targets numbers 001 thru 001 001 DID 0000EF WWN 202C00E0 00CB0815 Here are Luns numbers 0001 thru 0001 0001 Mode Peripheral dev LUN 0000 Selected Boot Device 001 DID 0000EF WWN 202C00E0 00CB0815 Mode Per LUN 0000 1 Boot this device via WWN 2 Boot this device via DID 01 DID 000000 WWN 202C00E0 00CB0815 Mode Per LUN 0000 02 DI...

Страница 411: ... com ts downloads index jsp D 4 5 Notes on replacing an FC card When an FC card to which the boot device is connected is replaced use the procedure described in Appendix D 4 4 Configuring the EFI driver to set the boot device for the replaced FC card Also make the required settings of the FC card according to the manuals for the FC switch and the storage devices to be connected z Change of zone se...

Страница 412: ...nd press the S key Do not connect the USB FDD to the USB port on an IO Unit Path switching at boot The boot entry for Windows Server 2003 for Itanium based Systems is created based on globally unique identifier GUID information The GUID represents a globally unique identifier Therefore if a failure occurs in a path between an FC switch and SAN storage for example the operating system can be booted...

Страница 413: ...eck all Error Warning Info Monitor More than one can be selected Selection of partition to be displayed Partition All radio buttons All Specified Switching between All and Specified retains the check box selection data on the Specified side Selection of target source for display Source all All Specified Switching between All and Specified retains the check box selection data on the Specified side ...

Страница 414: ...han the denominator of the displayed fraction The denominator of the displayed fraction indicates the total number of logged events System Information System name setting Setting PRIMEQUEST system name System Name PRIMEQUEST brand name Serial number Up to 64 characters can be entered Used also as an SNMP system name Asset tag information setting Asset management information setting Asset Tag None ...

Страница 415: ...rror Mode To change the Mirror Mode setting the chassis must be powered off For this reason apply the above setting to the system before the chassis is powered off System Power Control Cabinet power ON OFF control Power control of PRIMEQUEST system System Power Control None Power On all defined partition s are powered on Power On chassis only Power Off The chassis is powered off after all partitio...

Страница 416: ...e power on offevery month Specify the duration start date to end date of the monthly power on off and the period start month to end month of the monthly power on off schedule 4 Special Execute power on or power off on a specific day Specify the date on which power on or power off is executed Specify whether to turn power on or off on the specified execution date Specify the time at which power is ...

Страница 417: ...Setting of reserved SB Setting reserved SB Reserved SB Configuration None Free SB or SB already defined as a Reserved SB of a partition Boot Control Specification of boot device Specification of boot device Boot Selector No Override No Override Force boot into EFI Boot Manager Force PXE Force boot from DVD Setting of POST Power On Self Test Setting POST Power On Self Test POST Standard Diagnosis F...

Страница 418: ...e Enable Disable Add Edit User Setting user account Setting user name User name None 8 to 32 characters The following characters can be used to specify a user name 0 to 9 a to z A to Z and _ The first character must be a letter from a to z or A to Z Setting password Password None Specify a password consisting of 8 to 32 characters The password cannot be one that is easily guessed If the specified ...

Страница 419: ...to 255 0 to 255 0 to 255 Setting IP address of third NTP server NTP 3 None 0 to 255 0 to 255 0 to 255 0 to 255 Network Interface Setting system network Setting virtual IP address PRIMEQUEST 580A 540A 580 540 480 440 Virtual IP Address Specify the virtual IP address used to access the Web UI Setting MMB IP address PRIMEQUEST 520A 520 420 IP Address Specify the physical IP address assigned to the MM...

Страница 420: ...uto Auto 100M Full 100M Half 10M Full 10M Half Network Protocols HTTP HTTPS setting HTTP setting HTTP Disable Enable Disable Setting HTTP Port Number HTTP Port 8081 1024 to 65535 Enable disable HTTPS HTTPS Disable Enable Disable Setting HTTPS Port Number HTTPS Port 432 432 1024 to 65535 Setting HTTP HTTPS connection timeout HTTP HTTPS Timeout 600 s 0 60 9999 s Telnet setting Enable disable telnet ...

Страница 421: ... Auto Refresh Disable 5 to 999 s SNMP Community Setting system SNMP Setting SNMP System Location System Location None Character string Setting SNMP System Contact SNMP System Contact None Character string Setting SNMP community string Community User None Character string Setting access enabled IP Address or subnet IP Address MASK 1 0 to 255 0 to 255 0 to 255 0 to 255 Setting SNMP Version SNMP Vers...

Страница 422: ...Email Address None Up to 40 characters Create Selfsigned Certificate Creation of SSL certificate Term of self signing certificate validity Term None Number of days Length of private key bits Key length 1024 1024 2048 ISO country code of owner Country Name None Japan JP USA US State or province of owner State or Province Name None Up to 56 characters Owner locality name Locality Name None Up to 56 ...

Страница 423: ...rs uppercase and lowercase letters and en sized numeric characters can be used Password setting Password None 8 to 16 Only en sized alphabetic characters uppercase and lowercase letters and en sized numeric characters can be used Setting user account privileges Privilege No Access Admin Operator User CE No Access A user for which No Access is set does not have remote access to the system Setting f...

Страница 424: ...e Character string Alarm E Mail Filter Button Setting of notification destination e mail in predictive monitoring Selection of display severity check box Severity All check boxes Error Warning Info More than one option can be selected Selection of display partition check box Partition All check boxes Select partition s More than one option can be selected Selection of display target unit Unit All ...

Страница 425: ...ting for enabling operation as a 32 CPU system License None License for enabling the functions for operation as a 32 CPU system 32CPU License PRIMEQUEST 480 440 32 CPU license setting Setting for enabling operation as a 32 CPU system License None License for enabling the functions for operation as a 32 CPU system Window Major category Minor category Setting item Default value Possible values Remar...

Страница 426: ...SIGQUIT S M A R T setting S M A R T Monitoring Enable Enable Disable Watchdog setting Software Watchdog setting Watchdog Disable Enable Disable TimeOut 3600 sec 60 to 6000 sec This option can be specified only when Enable is set Watchdog Action No Action No Action Reset Power Off Power Cycle INIT This option can be specified only when Enable is set Boot Watchdog setting Watchdog Disable Enable Dis...

Страница 427: ...nit name directly Sort by Date Time New event first New event first Old event first Start Date Time First event First event Specified Time End Date Time End event End event Specified Time Number of events to display 1000 100 200 300 400 500 1000 Export List Export list Select File Top file latest File to be downloaded or deleted Only one option can be selected Export indication Keyword Blank Up to...

Страница 428: ......

Страница 429: ...enance For local maintenance For local maintenance For management by the user For management by the user Notes 1 The IP addresses in this figure are examples 3 Two subnets must be setup One for management by the user the other for remote maintenance Specify the same subnet for management by the user and for local maintenance 4 BMM 1 is supported only in the PRIMEQUEST 580A 540A 580 540 2 IP Physic...

Страница 430: ... Driver or PRIMECLUSTER GLS for Linux and by teaming of Intel PROset for Windows Note z If you want to use a switching hub that supports a loop guard function such as the spanning tree protocol and domain separation as an external switch suppress the loop guard function by disabling Spanning Tree Protocol for the port for connection between the switching hub and the main unit or by turning on Doma...

Страница 431: ...xternal switch suppress the loop guard function by disabling Spanning Tree Protocol for the port for connection between the switching hub and the main unit or by turning on Domain Separation BMM 1 BMM 1 IOU BMM 0 BMM 0 IOX REMOTE REMOTE IP 192 168 1 201 IP 192 168 1 100 IP 192 168 1 200 IP 192 168 3 202 IP 192 168 1 8 IP 192 168 1 1 MMB Web UI Web UI REMCS VIP 192 168 3 102 REMCS center Dial up ro...

Страница 432: ...er servers must be configured such that the packets with the physical IP address of MMB can pass through The destination server is an external server outside the firewall IP addresses are restricted by the mail server used Also if the REMOTE MAINTENANCE port is used with the PRIMEQUEST 520A under the above conditions the servers must be configured such that the packets with the IP addresses for RE...

Страница 433: ...er business system CLI Command Line Interface This interface with UNIX or DOS allows the user to enter commands and optional arguments to communicate with the OS CoA Abbreviation for Certificate of Authenticity This is a visual identifier that helps identify genuine Microsoft software and components COM Port Communication Port RS 232C serial port for PC AT compatible machines A COM port is also ca...

Страница 434: ...achine uses two types of FWH one type is mounted on an SB and the other is mounted in an IO Unit GAC Global Address Controller One of the ASICs developed by Fujitsu for the PRIMEQUEST series machine GbE Gigabit Ethernet Ethernet standards for high speed communication of up to 1 Gbps GDS Abbreviation for PRIMECLUSTER GDS GDX Global Data Xbar One of the ASICs developed by Fujitsu for the PRIMEQUEST ...

Страница 435: ...ple this network allows data to be transferred among computers and printers connected in a facility LDAP Lightweight Directory Access Protocol Protocol used to access directory databases in a TCP IP network such as the Internet and intranets LDX Local Data Xbar One of the ASICs developed by Fujitsu for the PRIMEQUEST series machine LED Abbreviation for a light emitting diode MAC address Media Acce...

Страница 436: ...slot expansion unit that is mounted in a PCI_Box Platform OS type or environment that is the basis for operation of application software POST Power On Self Test Hardware test that is automatically run when the computer is powered on Private LAN LAN used for internal control under which firmware programs installed on hardware components communicate with one another MMB firmware GSWB firmware and BM...

Страница 437: ...e American Standards Association SDRAM Synchronous DRAM Memory standard for access speeds that are higher than those of DRAM SEL System Event Log Information on the processing parameters processing and processing results logged during hardware and software operations SERDES Serializer Deserializer Parallel to serial converter from low speeds to high speeds SIRMS Software Product Information Collec...

Страница 438: ...t stores power and protects against possible damage and loss of computer data from a momentary voltage drop or unexpected power failure USB Universal Serial Bus One of the standards on connecting peripheral devices such as keyboards and mice VLAN Virtual LAN Function that logically groups the ports of one switching hub so each group works as an independent LAN Web UI Web User Interface Interface t...

Страница 439: ...eployment console A 9 deployment server 3 19 3 21 3 29 3 32 Detected previous version of PSA window 4 82 4 96 diskdump 4 113 DNS server setting up 2 21 DSNAP 4 123 4 131 A 5 dump area allocating 4 109 dump collection confirmation 4 121 dump device 4 109 dump environment 4 1 Linux Red Hat 4 106 Windows Server 2003 4 123 dump environment setting up 4 119 dump saving area 4 111 dump saving area setti...

Страница 440: ... 124 kernel parameter setting 4 120 kexec tool installing 4 118 L Linux backup 4 140 installation 3 5 installation method 3 1 Linux installation method comparison 3 2 Local Area Connection Properties dialog box 4 74 login 2 8 logout 2 8 M mail sending condition 2 24 maintenance completion window 4 84 4 98 maintenance status display 2 11 management LAN 2 26 4 4 4 23 4 39 4 69 4 88 management LAN du...

Страница 441: ...llation 4 21 4 36 4 65 update installation 4 20 4 35 4 64 4 80 4 94 R rebooting system 4 120 reference manual iii Remote Server Management window 3 20 3 30 Remove SB IOU from Partition window 2 56 reserved SB setting 2 43 2 59 S S M A R T 4 99 S M A R T window 4 100 S M A R T setting 4 99 safety note on vii SAN 3 24 SAN boot environment setup D 2 SB 2 43 2 51 merging 2 47 splitting 2 47 SB and IO ...

Страница 442: ...erm startup window 3 44 3 55 text convention iv title area 2 13 trap destination 4 14 4 29 4 57 4 75 4 89 U uninstallation PSA 4 21 4 36 4 65 4 84 4 98 SIRMS 4 21 4 36 update completion window 4 81 4 95 update installation PSA 4 20 4 35 4 64 4 80 4 94 SIRMS 4 21 4 35 update installation window 4 80 4 82 4 94 4 96 USB Video DVD Switch window 3 7 3 13 3 37 3 48 user account 2 26 2 30 registering 2 2...

Страница 443: ...oor Good Fair Poor Organization Accuracy Clarity Overall rating of this publication Use of examples Index coverage Cross referencing Legibility Binding Figures and tables General appearance Technical level Too detailed Appropriate Not enough detail For Users in U S A Canada and Mexico Fold and fasten as shown on back No postage necessary if mailed in U S A Fujitsu Computer Systems Attention Engine...

Страница 444: ...Y MAIL FIRST CLASS MAIL PERMIT NO 741 SUNNYVALE CA NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES POSTAGE WILL BE PAID BY ADDRESSEE FUJITSU COMPUTER SYSTEMS ATTENTION ENGINEERING OPS M S 249 1250 EAST ARQUES AVENUE SUNNYVALE CA 94085 5401 ...

Страница 445: ......

Страница 446: ...Back Cover ...

Отзывы: