C141-E112-01EN
5 - 64
At command issuance (I-O registers setting contents)
1F7
H
(CM)
1
1
1
1
0
0
1
0
1F6
H
(DH)
×
×
×
DV
xx
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(FR)
xx
xx
xx
xx
xx
At command completion (I-O registers setting contents)
1F7
H
(ST)
Status information
1F6
H
(DH)
×
×
×
DV
xx
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(ER)
xx
xx
xx
xx
Error information
(36-1)
SET MAX ADDRESS (F9)
This command allows the maximum address accessible by the user to be set in LBA or CHS
mode. Upon receipt of the command, the device sets the BSY bit and saves the maximum address
specified in the DH, CH, CL and SN registers. Then, it clears BSY and generates an interrupt.
The new address information set by this command is reflected in Words 1, 54, 57, 58, 60 and 61
of IDENTIFY DEVICE information. If an attempt is made to perform a read or write operation
for an address beyond the new address space, an ID Not Found error will result.
When SC register bit 0, VV (Value Volatile), is 1, the value set by this command is held even
after power on and the occurrence of a hard reset. When the VV bit is 0, the value set by this
command becomes invalid when the power is turned on or a hard reset occurs, and the maximum
address returns to the value (default value if not set) most lately set when VV bit = 1.
After power on and the occurrence of a hard reset, the host can issue this command only once
when VV bit = 1. If this command with VV bit = 1 is issued twice or more, any command
following the first time will result in an Aborted Command error.
Содержание MPG3102AH
Страница 1: ...C141 E112 01EN MPG3xxxAH DISK DRIVES PRODUCT MANUAL ...
Страница 3: ...This page is intentionally left blank ...
Страница 5: ...This page is intentionally left blank ...
Страница 9: ...This page is intentionally left blank ...
Страница 17: ...This page is intentionally left blank ...
Страница 33: ...C141 E112 01EN 3 2 Figure 3 1 Dimensions ...
Страница 195: ......