C141-E112-01EN
5 - 38
Subcommand code 42h allows the host to enable the Automatic Acoustic Management feature set.
To enable the Automatic Acoustic Management feature set, the host writes the Sector Count
register with the requested automatic acoustic management level and executes a SET FEATURES
command with subcommand code 42h. The acoustic management level is selected on a scale
from 01h to FEh. Following table shows the acoustic management level values.
Enabling or disabling of the Automatic Acoustic Management feature set, and the current
automatic acoustic management level setting will be preserved by the device across all forms of
reset, i.e., power on, hardware, and software resets.
Automatic management levels
Level
Sector Count value
Reserved
FFh
Maximum performance
C0h - FEh
Minimum acoustic emanation level
80h - BFh
Retired
01h - 7Fh
Vendor Specific (Maximum performance)
00h
Subcommand code C2h disables the Automatic Acoustic Management feature set. Devices that
implement SET FEATURES subcommand 42h are not required to implement subcommand C2h.
If device successfully completes execution of this subcommand, then the acoustic behavior of the
device shall be vendor-specific, and the device return zeros in bits 0-7 of word 94 and bit 9 of
word 86 of the IDENTIFY DEVICE data.
(15)
SET MULTIPLE MODE (X'C6')
This command enables the device to perform the READ MULTIPLE and WRITE MULTIPLE
commands. The block count (number of sectors in a block) for these commands are also specified
by the SET MULTIPLE MODE command.
The number of sectors per block is written into the Sector Count register. The IDD supports 2, 4,
8 and 16 (sectors) as the block counts.
Upon receipt of this command, the device sets the BSY bit of the Status register and checks the
contents of the Sector Count register. If the contents of the Sector Count register is valid and is a
supported block count, the value is stored for all subsequent READ MULTIPLE and WRITE
MULTIPLE commands. Execution of these commands is then enabled. If the value of the Sector
Count register is not a supported block count, an ABORTED COMMAND error is posted and the
READ MULTIPLE and WRITE MULTIPLE commands are disabled.
If the contents of the Sector Count register is 0 when the SET MULTIPLE MODE command is
issued, the READ MULTIPLE and WRITE MULTIPLE commands are disabled.
When the SET MULTIPLE MODE command operation is completed, the device clears the BSY
bit and generates an interrupt.
Содержание MPG3102AH
Страница 1: ...C141 E112 01EN MPG3xxxAH DISK DRIVES PRODUCT MANUAL ...