C141-E112-01EN
5 - 46
(24)
STANDBY (X'96' or X'E2')
Upon receipt of this command, the device sets the BSY bit of the Status register and enters the
standby mode. The device then clears the BSY bit and generates an interrupt. The device
generates an interrupt even if the device has not fully entered the standby mode. If the device has
already spun down, the spin-down sequence is not implemented.
If the contents of the Sector Count register is other than 0, the automatic power-down function is
enabled and the timer starts countdown when the device returns to idle mode.
When the timer value reaches 0 (passed a specified time), the device enters the standby mode.
If the contents of the Sector Count register is 0, the automatic power-down function is disabled.
Under the standby mode, the spindle motor is stopped. Thus, when the command involving a seek
such as the READ SECTOR(s) command is received, the device processes the command after
driving the spindle motor.
At command issuance (I/O registers setting contents)
1F7
H
(CM)
X'96' or X'E2'
1F6
H
(DH)
×
×
×
DV
xx
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(FR)
xx
xx
xx
Period of timer
xx
At command completion (I/O registers contents to be read)
1F7
H
(ST)
Status information
1F6
H
(DH)
×
×
×
DV
xx
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(ER)
xx
xx
xx
xx
Error information
(25)
STANDBY IMMEDIATE (X'94' or X'E0')
Upon receipt of this command, the device sets the BSY bit of the Status register and enters the
standby mode. The device then clears the BSY bit and generates an interrupt. This command does
not support the automatic power-down sequence.
Содержание MPG3102AH
Страница 1: ...C141 E112 01EN MPG3xxxAH DISK DRIVES PRODUCT MANUAL ...
Страница 3: ...This page is intentionally left blank ...
Страница 5: ...This page is intentionally left blank ...
Страница 9: ...This page is intentionally left blank ...
Страница 17: ...This page is intentionally left blank ...
Страница 33: ...C141 E112 01EN 3 2 Figure 3 1 Dimensions ...
Страница 195: ......