![Fujitsu MAS3184NC - Enterprise 18.4 GB Hard Drive Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/fujitsu/mas3184nc-enterprise-18-4-gb-hard-drive/mas3184nc-enterprise-18-4-gb-hard-drive_product-maintenance-manual_121505056.webp)
4-6
C141-E185
(3)
Limitation of bottom-mounting
Use all 4 mounting holes on the bottom face.
(4)
Environmental temperature
Temperature condition at installed in a cabinet is indicated with ambient temperature measured
30 mm from the disk drive. At designing the system cabinet, consider following points.
•
Make a suitable air flow so that the DE surface temperature does not exceed 60°C.
•
Cool the PCA side especially with air circulation inside the cabinet. Confirm the cooling effect
by measuring temperature of specific ICs and the DE. These measurement results should be
within a criteria listed in Table 4.1.
Table 4.1
Surface temperature check point
No.
Measurement point
Criteria
1
Center of DE cover
60°C
2
Read channel LSI
88°C
3
VCM/SPM Driver
92°C
4
HDC
91°C
5
MPU
91°C
1
4
5
2
3
Figure 4.6 Surface temperature measurement points
Содержание MAS3184NC - Enterprise 18.4 GB Hard Drive
Страница 1: ...C141 E185 01EN MAS3735NC NP MAS3367NC NP MAS3184NC NP DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Страница 10: ...This page is intentionally left blank ...
Страница 34: ...This page is intentionally left blank ...
Страница 72: ...4 22 C141 E185 IMPORTANT Do not connect the external LED to both CN1 and CN2 Connect it to either of them ...
Страница 96: ...This page is intentionally left blank ...
Страница 122: ...This page is intentionally left blank ...
Страница 126: ...This page is intentionally left blank ...
Страница 128: ...This page is intentionally left blankw ...
Страница 129: ......
Страница 130: ......