C141-E185
7-3
7.2
Sense Data Analysis
7.2.1
Error information indicated with sense data
Subsection 7.2.2 onwards explain troubleshooting using sense data.
Table 7.1 lists the definition of sense data. For details of sense data, refer to the SCSI
Logical Interface Specifications.
Table 7.1
Definition of sense data
Sense data
Sense
key
Sense
Code
Sub
Sense
Code
00
00
00
Operation was normal.
3
0C
03
A write to a disk terminated abnormally.
4
32
40
44
C4
01
xx
xx
xx
Failed to update the defect list due to a disk medium write error, etc.
An error occurred in power-on self-diagnosis.
A hardware error occurred inside IDD.
A drive error occurred.
1
3
1x
1x
xx
xx
A disk read error occurred.
A disk read error occurred.
E
1D
00
Data discrepancy found by VERIFY command byte check.
5
B
B
B
B
2x
3D
90
47
49
4D
4E
xx
00
00
xx
00
xx
00
An SCSI error, such as an invalid operation code, occurred.
The Reserve bit of the IDENTIFY message was set to 1.
The RESERVE or RELEASE command cannot be executed because
the SCSI ID of the INIT was not posted in the SELECTION phase.
A parity error occurred in the SCSI data bus.
An unmounted or inappropriate message was received.
Before completion of a command, a command with the same tag
number was issued.
An overlap command was issued.
Definition
Содержание MAS3184NC - Enterprise 18.4 GB Hard Drive
Страница 1: ...C141 E185 01EN MAS3735NC NP MAS3367NC NP MAS3184NC NP DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Страница 10: ...This page is intentionally left blank ...
Страница 34: ...This page is intentionally left blank ...
Страница 72: ...4 22 C141 E185 IMPORTANT Do not connect the external LED to both CN1 and CN2 Connect it to either of them ...
Страница 96: ...This page is intentionally left blank ...
Страница 122: ...This page is intentionally left blank ...
Страница 126: ...This page is intentionally left blank ...
Страница 128: ...This page is intentionally left blankw ...
Страница 129: ......
Страница 130: ......