Read/Write Error Recovery Parameters (Page Code = 1)
Fig. 3.8 shows the format of the page descriptor of this MODE SELECT parameter.
Bit
Byte
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
1
1
X‘0A’ or X‘06’ (Page Length)
2
AWRE
ARRE
TB
RC
ERR
PER
DTE
DCR
Default
0
0
1
0
1
0
0
0
Variable
1
1
1
1
1
1
1
1
3
Number of retries during READ
Default
X‘20’
Variable
X‘FF’
4
Correctable Bit Length
Default
X‘59’
Variable
X‘00’
5
X‘00’ (Head Offset Count)
6
X‘00’ (Data Strobe Offset Count)
7
X‘00’ (Reserved)
8
Number of retries during WRITE
Default
X‘00’
Variable
X‘FF’
9
X‘00’ (Reserved)
10-11
X‘0000’ (Recovery Time Limit)
Figure 3.8 MODE SELECT Parameters: Read/Write Error Recovery Parameters
Note
If transfer of this page descriptor is requested by the MODE SENSE or MODE
SENSE EXTENDED command, the IDD reports X '0A' as the page length (byte 1).
However, if either X '0A' or X '06' is specified for the page length in the MODE
SELECT or MODE SELECT EXTENDED command, the IDD treats it as though the
correct page length was specified. If X '06' is specified for the page length, the value
specified in the "Number of retries during READ" field is used as is in the "Number
of retries during WRITE" field and the value specified in the "Number of retries
during READ" field is also used as is in the "Number of retries during VERIFY"
field. The X '06' page length is included in consideration of compatibility with
previous models, but as much as possible, it is recommended that the INIT use the X
'0A' page length.