C141-E039-01EN
3 - 84
3.2.4
WRITE EXTENDED (2A)
Bit
Byte
7
6
5
4
3
2
1
0
0
X‘2A’
1
LUN
×
0
0
0
2
Logical Block Address (MSB)
3
Logical Block Address
4
Logical Block Address
5
Logical Block Address (LSB)
6
0
0
0
0
0
0
0
0
7
Transfer Block Count (MSB)
8
Transfer Block Count (LSB)
9
0
0
0
0
0
0
Flag
Link
This command transfers the number of blocks of data specified in the "Transfer block count"
field from the INIT and writes them in continuous logical data blocks with the logical data
block on the disk media specified in the "Logical block address" field in the CDB as the top.
The functions of this command are the same as those of the Group 0 WRITE command (item
3.2.3) with the exception that it is possible to specify 4-byte logical block addresses and 2-byte
transfer block counts. However, when zero is specified for the "Transfer block count," the
command is terminated normally without pre-fetch being performed.