Chapter 3 - Setup and Installation
Multi-Port Mirrored Dual Host-Single Connection Configuration
88
6
Connect the Fibre Channel data cable(s).
a
Connect a cable from the first host (Node A) HBA FC port to the “H0”
connector on the left Host I/O card.
b
Connect another cable from the second host (Node B) HBA FC port to
the “H1” connector on the right Host I/O card.
Multi-Port Mirrored Dual Host-Single Connection Cabling Diagram
7
If you wish to add additional enclosure(s), follow the instructions below.
Otherwise skip to step 13. The example depicts one extra enclosure being
added, however, you may wish to add more enclosures up to the allowable
limit of 96 drives.
8
Set the jumper (JP4) on the Disk I/O card installed in the expansion enclosure.
Loosen the two captive fastener screws on the Disk I/O card and pull it from
the daisy-chain enclosure using the fastener screws. Locate the jumper JP4
and position it for the desired speed setting, (installed on one pin only for 2
Gb mode and on both pins for 1 Gb mode).
SES
Host Computer Node B
H0
H1
H0
H1
RAID Controller
RAID Controller
Power
Supply
Power
Supply
Cooling
Fans
DISK I/O
Host Computer Node A
P1
RS-232
P2
DISK I/O
P1
P2
FC HBA
Connect to H1
Connect to H0
FC HBA
imageRAID IRF-2Sxx-xx/IRF-2Dxx-xx
imageRAID.book Page 88 Tuesday, September 23, 2003 4:08 PM
Содержание IRF-1D series
Страница 2: ...imageRAID book Page 2 Tuesday September 23 2003 4 08 PM ...
Страница 8: ...Table of Contents iv imageRAID book Page iv Tuesday September 23 2003 4 08 PM ...
Страница 164: ...Chapter 6 Maintenance Replacing the Enclosure 152 imageRAID book Page 152 Tuesday September 23 2003 4 08 PM ...
Страница 168: ...Appendix A Technical Information Specifications 156 imageRAID book Page 156 Tuesday September 23 2003 4 08 PM ...
Страница 180: ...Index 168 imageRAID book Page 168 Tuesday September 23 2003 4 08 PM ...
Страница 181: ...imageRAID book Page 7 Tuesday September 23 2003 4 08 PM ...