Chapter 6 - Maintenance
Replacing the Disk I/O Card
143
The transceiver can only be installed one way. Note the orientation and
ensure you are inserting it correctly. Push the transceiver fully into the SFP
cage so that it completely seats. The transceiver protrudes approximately
1/2-inch from the Disk I/O card face plate when it’s completely seated.
13
Remove the dust covers just prior to inserting the FC data cables. Store them
in a safe place.
14
Re-connect the Fibre Channel data cables to the replacement card.
15
Using the packaging materials from the replacement card, repackage the
failed card and return it per your RMA instructions.
imageRAID.book Page 143 Tuesday, September 23, 2003 4:08 PM