Chapter 1 - Getting Started
Spin-Up Settings
9
For example, if the setting for switches 1 through 3 are “Down.” the device ID
addresses for the drive slots 1 - 12 would be 0 - 11 respectively.
NOTE:
If a hard address ID conflict occurs during Fibre Channel loop
initialization, the Fibre Channel protocol will dynamically set the drive
IDs. This could cause problems with some software products.
Switches 4, 5, and 6 are not used.
Spin-Up Settings
Switches 7 and 8 control the drive spin-up functions. The switches are directly
attached to all of the drive slot start signals. Switch 7 controls the “Start_1” signal
(Delay Spin-up) and switch 8 controls the “Start_2” signal (Remote Spin-up).
The table below describes the function of each switch.
“DL” Switch 7
“RM” Switch 8
Drive Spin-up Mode
Down (0)*
Down (0)*
Drive motor spins up at DC power on.
Down (0)
Up (1)
Drive motor spins up only on SCSI “start”
commands.
Up (1)
Down (0)
Drive motor spins up after a delay of 12
(may vary depending on drive type) seconds
times the numeric ID setting of the
associated drive.
Up (1)
Up (1)
Drive motor will not spin-up.
* Default setting for proper operation.
imageRAID.book Page 9 Tuesday, September 23, 2003 4:08 PM
Содержание IRF-1D series
Страница 2: ...imageRAID book Page 2 Tuesday September 23 2003 4 08 PM ...
Страница 8: ...Table of Contents iv imageRAID book Page iv Tuesday September 23 2003 4 08 PM ...
Страница 164: ...Chapter 6 Maintenance Replacing the Enclosure 152 imageRAID book Page 152 Tuesday September 23 2003 4 08 PM ...
Страница 168: ...Appendix A Technical Information Specifications 156 imageRAID book Page 156 Tuesday September 23 2003 4 08 PM ...
Страница 180: ...Index 168 imageRAID book Page 168 Tuesday September 23 2003 4 08 PM ...
Страница 181: ...imageRAID book Page 7 Tuesday September 23 2003 4 08 PM ...