12. External input and output
With using external input and output functions, this product can be operated inter-connectedly
with an external device.
Connector
Input
Output
Remarks
CN131
Low noise mode
—
See external input/output
settings for details.
CN132
Peak cut mode
—
CN136
—
Error status
CN137
—
Compressor status
12-1. External input
With using external input function, on/off status of “Low noise mode” and “Peak cut mode” can be
specified by the external signal.
¢
Low noise mode
In following condition, the operating noise of the outdoor unit reduces comparing from the one in
normal operating condition:
The air conditioner is set to the “Low noise mode” when closing the contact input of a commercial
timer or on/off switch to a connector on the control PCB of the outdoor unit.
NOTE:
Product performance may drop depending on some conditions such as the outdoor tem-
perature.
Circuit diagram example (CN131)
Outdoor unit
control PCB
Connected unit
Example: Switch
Signal
*10 m
Connector
Locally purchased
CN131
• Contact capacity: DC 24 V or more, 10 mA or
more.
• *: Make the distance from the PCB to the connect-
ed unit within 10 m.
• Construct a circuit as shown in this figure with us-
ing optional parts mentioned below.
• Input signal: On in “Low noise mode”
• Input signal: Off in normal operation
• To set the level of “Low noise mode”, refer to
On
Off
On
Off
Input signal
Low noise mode
Optional part
Part name
Model name
Exterior
External connect kit
UTY-XWZXZ3
- 69 -
OUTDOOR UNIT
AOHG72-90LRLA
Содержание GENERAL ARHG72LHTA
Страница 5: ...Part 1 INDOOR UNIT DUCT TYPE ARHG72LHTA ARHG90LHTA ...
Страница 11: ...4 Wiring diagrams 4 1 Model ARHG72LHTA I O PCB WLAN adapter Converter etc 7 DUCT TYPE ARHG72 90LHTA ...
Страница 12: ...4 2 Model ARHG90LHTA I O PCB WLAN adapter Converter etc 8 DUCT TYPE ARHG72 90LHTA ...
Страница 57: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOHG72LRLA AOHG90LRLA ...
Страница 64: ...5 Wiring diagrams 5 1 Models AOHG72LRLA and AOHG90LRLA 60 OUTDOOR UNIT AOHG72 90LRLA ...