[Selected range] check box
Select the check box to specify the detection range (colored in light pink) in the figure below.
The check box is cleared for the factory default settings.
Clearing this check box sets both start and end positions to "0", and overlapped documents are detected
within the whole document.
The above condition applies when the document is set to the center of the pick roller width.
If documents are overlapped within 30 mm from the leading edge, they are not detected as overlapped.
Disable (Middle)
This can be selected when the [Selected range] check box is selected.
Overlapped documents are not detected within the specified area.
This is the factory default setting.
Enable (Middle)
This can be selected when the [Selected range] check box is selected.
Overlapped documents are detected within the specified area.
Start (Middle)
Specify the start position of the detection area by the length from the leading edge of the document in
the feeding direction.
Range: 0 to 510 mm, in 2 mm increments, Start < End
The factory default setting is "0".
End (Middle)
Specify the end position of the detection area by the length from the leading edge of the document in
the feeding direction.
Range: 0 to 510 mm, in 2 mm increments, Start < End
The factory default setting is "0".
Scanner Settings (Software Operation Panel)
186
Содержание FI-800R
Страница 1: ...P3PC 6672 01ENZ2 FUJITSU Image Scanner fi 800R Operator s Guide ...
Страница 21: ... Inside ADF Scanner Overview 21 ...
Страница 47: ...HINT The following documents can be loaded Office paper Long page document How to Load Documents 47 ...
Страница 153: ...4 Click the OK button The password is set Scanner Settings Software Operation Panel 153 ...
Страница 155: ...The password is cleared Scanner Settings Software Operation Panel 155 ...
Страница 157: ...4 Click the OK button The password is set Scanner Settings Software Operation Panel 157 ...
Страница 179: ...HINT This setting is effective only for scanning images in black white Scanner Settings Software Operation Panel 179 ...
Страница 201: ...Outer Dimensions The outer dimensions are as follows Unit mm in Appendix 201 ...