6
Click the [Set] button to apply the specified settings.
A confirmation screen appears.
7
Click the [OK] button.
The event notification settings are applied.
8
Check the setting completion message and click the [Done] button.
The screen display returns to the [Event/Dump] screen.
6.2
Various Notification Settings
To monitor an ETERNUS DX Disk storage system, perform the required settings for device error notification.
6.2.1
SNMP Trap Setup
SNMP Trap can be sent to the SNMP Manager (monitoring server) when an event occurs in the ETERNUS DX
Disk storage system.
The SNMP Trap setting is explained below.
Carefully read this manual and the manuals for the monitoring software (SNMP Manager) that is to be
used before monitoring the ETERNUS DX Disk storage system.
■
ETERNUS DX Disk Storage System Settings
The SNMP Trap test setting is explained below.
1
Set up the network environment for the ETERNUS DX Disk storage system.
When the ETERNUS DX Disk storage system and the monitoring server are in different subnet environ-
ments, set the Gateway IP address and the Allowable IP address (IP address of the monitoring server or
the network address to which the monitoring server belongs) on the [Setup Network Environment]
screen of ETERNUS Web GUI.
Chapter 6 Monitoring Settings
6.2 Various Notification Settings
102
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Configuration Guide (Basic)
Copyright 2014 FUJITSU LIMITED
P3AM-7652-02ENZ0