Displaying event logging
Managing logging functions
326
U41855-J-Z125-3-76
All events
Ê
Select
Logging
→
Event Logging
,
All events
tab.
In this group, all occurred events are listed.
Default sorting and scope of the listed results
In both tabs, the default sorting is by the time stamp of the events, with the newest event
listed first.
In the
All Events
tab you can use the
Period:
field to filter for entries from a certain time.
i
To ensure that the time stamps are consistent, it is required that all units (MU,
SU x86, HNC etc.) are synchronized with an NTP server.
See also
section “NTP server” on page 36
.
To restrict the number of displayed results, you can filter by the following criteria:
–
Weight of the event (e.g. >=WARNING, >=ERROR, >=CRITICAL)
–
Name of the unit on which the message was issued
–
Component that issued the warning (e.g. M2000, X2000, Sys-Mgmt, cluster or name of
an installed add-on)
–
Message text
i
The currently possible events with messages are listed in the online help of the SE
Manager under "Further information".
Содержание BS2000
Страница 12: ...Content U41855 J Z125 3 76 ...
Страница 102: ...Working with the SE Manager Operating the SE Manager 100 U41855 J Z125 3 76 ...
Страница 156: ...Installing an operating system on an Application Unit Systems on Application Units 154 U41855 J Z125 3 76 ...
Страница 296: ...Managing energy settings Managing hardware 294 U41855 J Z125 3 76 ...
Страница 300: ...Managing an SU Cluster Managing a cluster 298 U41855 J Z125 3 76 ...
Страница 332: ...Alarm management Managing logging functions 330 U41855 J Z125 3 76 ...
Страница 356: ...Working with EMDS Appendix 354 U41855 J Z125 3 76 ...
Страница 366: ...Related publications 364 U41855 J Z125 3 76 ...