4-2. Heating capacity
NOTE:
Values mentioned in the table are calculated based on the maximum capacity.
¢
Model: AUXG09KVLA
AFR
m
3
/h
540
Indoor temperature
°CDB
16
18
20
22
24
Outdoor temperature
°CDB
°CWB
TC
IP
TC
IP
TC
IP
TC
IP
TC
IP
kW
kW
kW
kW
kW
-15
-16
2.10
0.79
2.05
0.80
2.00
0.82
1.95
0.84
1.90
0.85
-10
-11
2.47
0.84
2.41
0.85
2.35
0.87
2.29
0.89
2.23
0.90
-5
-7
2.84
0.88
2.77
0.90
2.70
0.92
2.63
0.94
2.57
0.96
0
-2
3.44
1.04
3.36
1.06
3.28
1.08
3.20
1.10
3.12
1.12
5
3
3.91
1.13
3.81
1.16
3.72
1.18
3.63
1.20
3.53
1.23
7
6
4.10
1.17
4.00
1.20
3.90
1.22
3.80
1.24
3.71
1.27
10
8
4.20
1.18
4.10
1.21
4.00
1.23
3.90
1.25
3.80
1.28
15
10
4.48
1.21
4.38
1.23
4.27
1.26
4.16
1.29
4.06
1.30
20
15
4.45
1.03
4.35
1.05
4.24
1.07
4.13
1.09
4.03
1.11
24
18
4.47
0.92
4.37
0.94
4.26
0.96
4.15
0.98
4.05
0.99
¢
Model: AUXG12KVLA
AFR
m
3
/h
600
Indoor temperature
°CDB
16
18
20
22
24
Outdoor temperature
°CDB
°CWB
TC
IP
TC
IP
TC
IP
TC
IP
TC
IP
kW
kW
kW
kW
kW
-15
-16
2.59
0.91
2.53
0.93
2.47
0.95
2.41
0.97
2.35
0.99
-10
-11
2.87
0.95
2.80
0.97
2.73
0.99
2.66
1.01
2.59
1.03
-5
-7
3.24
0.98
3.17
1.00
3.09
1.02
3.01
1.04
2.94
1.06
0
-2
3.85
1.15
3.76
1.18
3.67
1.20
3.58
1.22
3.49
1.25
5
3
4.40
1.28
4.29
1.30
4.19
1.33
4.09
1.36
3.98
1.38
7
6
4.62
1.32
4.51
1.35
4.40
1.38
4.29
1.41
4.18
1.44
10
8
4.78
1.27
4.66
1.29
4.55
1.32
4.44
1.35
4.32
1.37
15
10
5.04
1.17
4.92
1.20
4.80
1.22
4.68
1.24
4.56
1.26
20
15
4.87
1.23
4.76
1.25
4.64
1.28
4.52
1.31
4.41
1.32
24
18
5.04
1.11
4.92
1.14
4.80
1.16
4.68
1.18
4.56
1.20
¢
Model: AUXG14KVLA
AFR
m
3
/h
800
Indoor temperature
°CDB
16
18
20
22
24
Outdoor temperature
°CDB
°CWB
TC
IP
TC
IP
TC
IP
TC
IP
TC
IP
kW
kW
kW
kW
kW
-15
-16
3.15
1.13
3.08
1.16
3.00
1.18
2.93
1.20
2.85
1.23
-10
-11
3.66
1.21
3.58
1.23
3.49
1.26
3.40
1.29
3.32
1.31
-5
-7
4.22
1.30
4.12
1.32
4.02
1.35
3.92
1.38
3.82
1.40
0
-2
5.15
1.56
5.02
1.59
4.90
1.62
4.78
1.65
4.66
1.68
5
3
5.42
1.66
5.29
1.70
5.16
1.73
5.03
1.76
4.90
1.80
7
6
5.57
1.54
5.43
1.57
5.30
1.60
5.17
1.63
5.04
1.66
10
8
5.74
1.56
5.61
1.59
5.47
1.62
5.33
1.65
5.20
1.68
15
10
5.87
1.45
5.73
1.48
5.59
1.51
5.45
1.54
5.31
1.56
20
15
5.44
1.13
5.31
1.16
5.18
1.18
5.05
1.20
4.92
1.22
24
18
5.75
1.14
5.62
1.17
5.48
1.19
5.34
1.21
5.21
1.23
¢
Model: AUXG18KVLA
AFR
m
3
/h
800
Indoor temperature
°CDB
16
18
20
22
24
Outdoor temperature
°CDB
°CWB
TC
IP
TC
IP
TC
IP
TC
IP
TC
IP
kW
kW
kW
kW
kW
-15
-16
3.86
1.16
3.77
1.19
3.68
1.21
3.59
1.23
3.50
1.26
-10
-11
4.39
1.24
4.28
1.26
4.18
1.29
4.08
1.32
3.97
1.34
-5
-7
4.91
1.32
4.80
1.35
4.68
1.38
4.56
1.41
4.45
1.44
0
-2
5.93
1.61
5.79
1.65
5.65
1.68
5.51
1.71
5.37
1.75
5
3
6.36
1.71
6.21
1.74
6.06
1.78
5.91
1.82
5.76
1.85
7
6
6.62
1.76
6.46
1.79
6.30
1.83
6.14
1.87
5.99
1.90
10
8
6.98
1.79
6.82
1.82
6.65
1.86
6.48
1.90
6.32
1.93
15
10
7.59
1.82
7.41
1.86
7.23
1.90
7.05
1.94
6.87
1.97
20
15
6.95
1.50
6.79
1.53
6.62
1.56
6.45
1.59
6.29
1.61
24
18
6.89
1.51
6.72
1.54
6.56
1.57
6.40
1.60
6.23
1.63
- 11 -
4-2. Heating capacity
4. Capacity table
CASSETTE TYPE
AUXG09-22KVLA
CASSETTE TYPE
AUXG09-22KVLA
Содержание AUXG09KVLA
Страница 5: ...12 1 Models AOYG09KATA AOYG12KATA AOYG14KATA AOYG18KATA and AOYG22KATA 78 CONTENTS continued ...
Страница 6: ......
Страница 7: ...Part 1 INDOOR UNIT CASSETTE TYPE AUXG09KVLA AUXG12KVLA AUXG14KVLA AUXG18KVLA AUXG22KVLA ...
Страница 56: ... 50 11 3 Others 11 Optional parts CASSETTE TYPE AUXG09 22KVLA CASSETTE TYPE AUXG09 22KVLA ...
Страница 57: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOYG09KATA AOYG12KATA AOYG14KATA AOYG18KATA AOYG22KATA ...