11. Safety devices
Type of
protection
Protection form
Model
AOYG09KATA
AOYG12KATA
AOYG14KATA
Circuit
protection
Current fuse (Main PCB)
250 V, 20 A
250 V, 5 A
Fan motor
protection
Terminal protection
program
Activate
127 ±5 °C
Fan motor stop
Reset
95 °C or less
Fan motor restart
Compressor
protection
Terminal protection
program
(Discharge temp.)
Activate
110 °C
Compressor stop
Reset
After 7 minutes
Compressor restart
Thermal protection
program (Outdoor temp.)
Activate
-20 °C
Compressor stop
Reset
-15 °C
Compressor restart
Type of
protection
Protection form
Model
AOYG18KATA
AOYG22KATA
Circuit
protection
Current fuse (Main PCB)
250 V, 20 A
250 V, 25 A
250 V, 5 A
Fan motor
protection
Terminal protection
program
Activate
127 ±5 °C
Fan motor stop
125 ±10 °C
Fan motor stop
Reset
95 °C or less
Fan motor restart
120 ±10 °C
Fan motor restart
Compressor
protection
Terminal protection
program
(Discharge temp.)
Activate
110 °C
Compressor stop
Reset
After 7 minutes
Compressor restart
Thermal protection
program (Outdoor temp.)
Activate
-20 °C
Compressor stop
Reset
-15 °C
Compressor restart
- 77 -
11. Safety devices
OUTDOOR UNIT
AOYG09-22KATA
OUTDOOR UNIT
AOYG09-22KATA
Содержание AUXG09KVLA
Страница 5: ...12 1 Models AOYG09KATA AOYG12KATA AOYG14KATA AOYG18KATA and AOYG22KATA 78 CONTENTS continued ...
Страница 6: ......
Страница 7: ...Part 1 INDOOR UNIT CASSETTE TYPE AUXG09KVLA AUXG12KVLA AUXG14KVLA AUXG18KVLA AUXG22KVLA ...
Страница 56: ... 50 11 3 Others 11 Optional parts CASSETTE TYPE AUXG09 22KVLA CASSETTE TYPE AUXG09 22KVLA ...
Страница 57: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOYG09KATA AOYG12KATA AOYG14KATA AOYG18KATA AOYG22KATA ...