3. Installation space
3-1. Models: AOYG09KATA, AOYG12KATA, AOYG14KATA,
AOYG18KATA, and AOYG22KATA
¢
Space requirement
Provide sufficient installation space for product safety.
CAUTION
Keep the space shown in the installation examples.
If the installation is not performed accordingly, it could cause a short circuit and result in a lack of
operating performance.
Single outdoor unit installation
•
When the upper space is open:
Unit: mm
Obstacles at rear only
Obstacles at rear and sides
100 or more
250 or more
100 or more
100 or more
Obstacles at front
Obstacles at front and rear
600 or more
600 or more
100 or more
•
When there is an obstruction in the upper space:
Unit: mm
Obstacles at rear and above
Obstacles at rear, sides, and above
100 or more
Max. 200
600 or more
250 or more
100 or more
Max. 200
100 or more
600 or more
- 57 -