Fujitsu ASTG12CMCB Скачать руководство пользователя страница 5

En-5

6. INSTALLATION WORK

 WARNING

During transportation and relocation shall be covered by wall hook bracket to the con-
necting pipe. With a connection pipe, that I do not carry.
(When operating, There is a possibility that the stress is applied to the pipe joint, 

fl

 am-

mable gas may leak.)

 CAUTION

•  Do not hit or push the human sensor. This may lead to damage or malfunction.
•  Do not touch the human sensor. Any scratches or dirt may lead to incorrect detection.
•  Do not place large objects near the human sensor. Also keep heating units outside the 

sensor’s detection area.

90°

7 m

7 m

50°

50°

Detection range of the human sensor is as follows.

Vertical angle 90° (Side view)

Horizontal angle 100° (Top view)

6.1. Installation dimensions

     

 

70 mm or over 

1.5 m or over 

Remote 

controller

Remote controller holder

Tapping screw (small)

1.8 m 

or over

(Wallcap)

63 mm or over

Wall hook 

bracket

130 mm or over

=

6.2. Indoor unit piping direction

The piping can be connected in the 6 directions indicated in the following.
When the piping is connected to direction (2) , (3) , (4) or (5) , cut along the piping groove 
on the side of the front cover with a hacksaw.

(2)  Right 

outlet

(5)  Left 

outlet

(6)  Left rear 

outlet

(3)  Bottom outlet

(1)  Rear outlet

(4)  Left bottom outlet

(Rear)

6.3. Cutting the hole in the wall for the connecting piping

(1)  Cut a 65 mm diameter hole in the wall at the position shown in the following.
(2)  Cut the hole so that the outside end is lower (5 to 10 mm) than the inside end.
(3)  Always align the center of the wall hole. If misaligned, water leakage will occur.
(4)  Cut the wall pipe to match the wall thickness, stick it into the wall cap, fasten the cap with 

vinyl tape, and stick the pipe through the hole.

(5)  

For left piping and right piping, cut the hole a little lower so that drain water will 

fl

 ow 

freely.

65 mm dia. hole

65 mm dia. hole

Center mark

Wall hook bracket

Center mark

Wall

Fasten with 
vinyl tape

Wall cap*

Wall pipe*

(Inside)

(Outside)

5 to 10 mm low

*Locally purchased

 WARNING

Always use the wall pipe. If the wall pipe is not used, the cable that is connected 
between the indoor unit and the outdoor unit may touch metal, and cause an electric 
discharge.

6.4. Installing the wall hook bracket

• Remove the wall hook bracket from the indoor unit. (Remove 2 screws).
(1) Install the wall hook bracket so that it is correctly positioned horizontally and vertically. 

If the wall hook bracket is titled, water will drip to the 

fl

 oor.

(2) Install the wall hook bracket so that it is strong enough to support the weight of the unit.

• Fasten the wall hook bracket to the wall with 5 or more screws through the holes 

near the outer edge of the bracket.

• Check that there is no rattle at the wall hook bracket.

Wall hook bracket

Tapping screw

 CAUTION

Install the wall-hook bracket both horizontally and vertically aligned. 
Misaligned installation may cause water leakage.

6.5. Forming the drain hose and pipe

[Rear piping, Right piping, Bottom piping]

• Install the indoor unit piping in the direction of the wall hole and bind the drain hose 

and pipe together with vinyl tape.

• Install the piping so that the drain hose is at the bottom.
• Wrap the pipes of the indoor unit that are visible from the outside with decorative tape.

[For Left rear piping (Drain hose), Left piping (Drain hose)]

Interchange the drain cap and the drain hose.

 CAUTION

•  Insert drain hose and drain cap securely. Drain should slope down to avoid water leakage.

•  When inserting the drain hose, no other material than water should be applied. 

Application of other material than water will cause deterioration of the hose, and may 

cause water leakage.

•  After you remove a drain hose, be sure to attach the drain cap.

•  When you secure the piping and drain hose with tape, arrange the drain hose so that 

it is at the bottom of piping.

•  For drain hose piping in low temperature environment, you need to apply freeze 

protection to prevent a frozen drain hose. 

After cooling operation is performed in low temperature environment, (when outdoor 

temperature under 0 °C,) water in the drain hose could be frozen. Frozen drain water 

will block the water 

fl

 ow in the hose, and may cause water leakage at the indoor unit.

Installing the Drain cap 

Use a hexagonal wrench 4 mm at opposite side to 
insert the drain cap, till the drain cap contacts the tip 
of the drain cock.

Right piping

Bottom piping

Bind with vinyl tape

Refrigerant pipes (top)

Rear piping

Indoor unit drain hose (bottom)

No gap

Hexagonal 
wrench

Drain 

cock

Drain cap

9333005201_IM_En_ASTG09KMCA.indd   5

9333005201_IM_En_ASTG09KMCA.indd   5

2017/1/20   11:43:04

2017/1/20   11:43:04

Содержание ASTG12CMCB

Страница 1: ...ult experienced service technicians for disconnection and reinstallation of the unit Do not place any other electrical products or household belongings under indoor unit or outdoor unit Condensation dripping from the unit might get them wet and may cause damage or malfunction of your property Be careful not to scratch the air conditioner when handling it After installation explain correct operatio...

Страница 2: ...onents During repairs to sealed components all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servic ing then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation P...

Страница 3: ...hall be complete with leak free disconnect couplings and in good condition Before using the recovery machine check that it is in satisfactory working order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered refrigerant shall be returned to the refrigerant supp...

Страница 4: ...t piping 4 ELECTRICAL REQUIREMENT The indoor unit is powered from the outdoor unit Do not power indoor unit from separate power source WARNING Standard for electrical wiring and equipment differs in each country or region Before you start electrical working confirm related regulations codes or standards Cable Conductor size mm2 Type Remarks Connection cable 1 5 Type 60245 IEC 57 3 cable Earth Grou...

Страница 5: ... an electric discharge 6 4 Installing the wall hook bracket Remove the wall hook bracket from the indoor unit Remove 2 screws 1 Install the wall hook bracket so that it is correctly positioned horizontally and vertically If the wall hook bracket is titled water will drip to the floor 2 Install the wall hook bracket so that it is strong enough to support the weight of the unit Fasten the wall hook ...

Страница 6: ...r water from entering the pipes Die A Pipe B L Check if L is flared uniformly and is not cracked or scratched Pipe outside diameter mm in Dimension A mm Dimension B mm Flare tool for R32 clutch type 6 35 1 4 0 to 0 5 9 1 9 52 3 8 13 2 12 70 1 2 16 6 15 88 5 8 19 7 19 05 3 4 24 0 When using conventional flare tools to flare R32 pipes the dimension A should be approx imately 0 5 mm more than indicat...

Страница 7: ...lastic jacket portion but not at the insulator portion If the insulator is chafed electric leakage may occur Always connect the earth ground wire Improper earthing grounding work can cause electric shocks Do not use the earth ground screw for the indoor unit to the outdoor unit unless it is specified 7 ELECTRICAL WIRING CAUTION Be careful not to generate a spark as follows for using a flammable re...

Страница 8: ...val 2 Remove 3 caps 3 Remove wire cover 4 Remove 7 screws Screws Wire cover Screws 6 position Caps 3 position Wire cover 5 The front panel is pulled to the front raising the upper surface and a front panel is removed Front panel 9 2 Front panel installation 1 First fit the lower part of the front panel and insert top and bottom hooks 3 top sides 2 center Indoor unit Front panel Latches 2 position ...

Страница 9: ...l kit confirm whether the air conditioner receives the signal from the remote controller Do not connect the wired remote controller to the terminal for power supply When connecting the wired remote controller with the indoor unit use the connecting cable that is supplied with wired remote controller or simple remote controller Recommended cable length of wired remote controller is 10 m When you ex...

Страница 10: ...nd pull off the lock at the side of the connector insertion part CAUTION Be careful not to damage the parts on the board Otherwise it will cause malfunction Connector number CN 5 Connector number CN 4 Connector number CN 10 Connector number CN 7 Symbol indicating the location printed on the board 4 Remove the wires from the three fixtures See the figure below Leave the thick green wire in fixture ...

Страница 11: ... in the oval circles below Then connect the connectors in the squares to the terminals respectively Each terminal should form a pair with a connector CAUTION Ensure that the connector is properly inserted Otherwise it may result in erroneous operation Be careful not to damage the parts on the board Otherwise it will cause malfunction 4 Wired remote controller cable External connect kit cable sold ...

Страница 12: ...ress the RESET button to enter the function setting mode Selecting the Function Number and Setting Value Reverse cycle model 1 Press the TEMP buttons to select the func tion number Press the 10 C HEAT button to switch between the left and right digits 2 Press the POWERFUL button to proceed to setting value Press the POWERFUL button again to return to the function number selection 3 Press the TEMP ...

Страница 13: ... converter the setting cannot be made by using the remote controller Set to 00 or 01 To confirm if the remote controller has this function refer to the operating manual of each remote controller Setting record Record any changes to the settings in the following table Setting Description Setting Value Filter sign Auto restart Room temperature sensor switching Remote controller custom code External ...

Страница 14: ...peration Error display Wired remote controller Error code Description OPERATION lamp green TIMER lamp orange ECONOMY lamp green 1 1 Serial communication error 1 2 Wired remote controller communication error 1 5 Check run unfinished 1 6 Peripheral unit transmission PCB connection error 1 8 External communication error 2 1 Unit number or Refrigerant circuit address setting error Simultaneous Multi 2...

Страница 15: ...rror 9 9 4 way valve error 9 10 Coil expansion valve error 10 1 Discharge temp error 10 3 Compressor temp error 10 4 High pressure error 10 5 Low pressure error 13 2 Branch boxes error Flexible Multi Display mode 0 5s ON 0 5s OFF 0 1s ON 0 1s OFF Number of flashing Troubleshooting with the indoor unit display OPERATION indicator green TIMER indicator orange ECONOMY indicator green Troubleshooting ...

Страница 16: ......

Отзывы: