Room temperature control for wired remote controller sensor

Depending on the installed environment, correction of the wire remote temperature sensor 
may be required.
Select the appropriate control setting according to the installed environment.
To change this setting, set Function 42 to Both “01”.
Ensure that the Thermo Sensor icon is displayed on the remote controller screen.

(

...  Factory setting)

Function number

Setting 

value

Setting description

35

(For cooling)

36

(For heating)

00

No correction 0.0°C

01

No correction 0.0°C

02

-0.5°C

More 

Cooling 

Less 

Heating

03

-1.0°C

04

-1.5°C

05

-2.0°C

06

-2.5°C

07

-3.0°C

08

-3.5°C

09

-4.0°C

10

+0.5°C

Less 

Cooling 

More 

Heating

11

+1.0°C

12

+1.5°C

13

+2.0°C

14

+2.5°C

15

+3.0°C

16

+3.5°C

17

+4.0°C

Setting record

  Record any changes to the settings in the following table.

Setting

Setting Value

Heat Insulation condition (building insula-
tion)
Room temperature control for indoor unit 
sensor

Cooling
Heating

Room temperature control for wired remote 
controller sensor

Cooling
Heating

After completing the Function Setting, be sure to turn off the power and turn it on again.

16. CUSTOMER GUIDANCE

Explain the following to the customer in accordance with the operating manual:
(1)  Starting and stopping method, operation switching, temperature adjustment, timer, air 

fl

 ow switching, and other remote control unit operations.

(2)  Air 

fi

 lter removal and cleaning, and how to use the air louvers.

(3) Give the operating manual to the customer.

17. ERROR CODES

If you use a wireless remote controller, the lamp on the photo detector unit will output error 
codes by way of blinking patterns. If you use a wired remote controller, error codes will ap-
pear on the remote control display. See the lamp blinking patterns and error codes in the 
table. An error display is displayed only during operation.

Error display

Wired 

remote 

controller 

Error code

Description

OPERATION 
lamp (green)

TIMER 

lamp 

(orange)

ECONOMY 

lamp 

(green)

(1)

(1)

Serial communication error

(1)

(2)

Wired remote controller 
communication error

(1)

(5)

Check run unfinished

(1)

(6)

Peripheral unit transmission PCB 
connection error

(1)

(8)

External communication error

(2)

(1)

Unit number or Refrigerant circuit 
address setting error 
[Simultaneous Multi]

(2)

(2)

Indoor unit capacity error

Error display

Wired 

remote 

controller 

Error code

Description

OPERATION 
lamp (green)

TIMER 

lamp 

(orange)

ECONOMY 

lamp 

(green)

(2)

(3)

Combination error

(2)

(4)

• Connection unit number 

error (indoor secondary unit) 
[Simultaneous Multi]

• Connection unit number error 

(indoor unit or branch unit) 
[Flexible Multi]

(2)

(6)

Indoor unit address setting error

(2)

(7)

Primary unit, secondary unit setup 
error [Simultaneous Multi]

(2)

(9)

Connection unit number error in 
wired remote controller system

(3)

(1)

Power supply interruption error

(3)

(2)

Indoor unit PCB model 
information error

(3)

(5)

Manual auto switch error

(3)

(10)

Indoor unit communication circuit 
(wired remote controller) error

(4)

(1)

Room temp. sensor error 

(4)

(2)

Indoor unit Heat Ex. Middle temp. 
sensor error

(4)

(4)

Human sensor error

(5)

(1)

Indoor unit fan motor error

(5)

(3)

Drain pump error

(5)

(7)

Damper error 

(5)

(8)

Intake grille error

(5)

(15)

Indoor unit error

(6)

(1)

Outdoor unit reverse/missing 
phase and wiring error

(6)

(2)

Outdoor unit main PCB 
model information error or 
communication error

(6)

(3)

Inverter error 

(6)

(4)

Active filter error, PFC circuit error 

(6)

(5)

Trip terminal L error

(6)

(10)

Display PCB microcomputers 
communication error

(7)

(1)

Discharge temp. sensor error

(7)

(2)

Compressor temp. sensor error

(7)

(3)

Outdoor unit Heat Ex. liquid temp. 
sensor error

(7)

(4)

Outdoor temp. sensor error

(7)

(5)

Suction Gas temp. sensor error

(7)

(6)

• 2-way valve temp. sensor error
• 3-way valve temp. sensor error

(7)

(7)

Heat sink temp. sensor error

(8)

(2)

• Sub-cool Heat Ex. gas inlet 

temp. sensor error

• Sub-cool Heat Ex. gas outlet 

temp. sensor error

(8)

(3)

Liquid pipe temp. sensor error

(8)

(4)

Current sensor error

9333005201_IM_En_ASTG09KMCA.indd   14

9333005201_IM_En_ASTG09KMCA.indd   14

2017/1/20   11:43:07

2017/1/20   11:43:07

Содержание ASTG12CMCB

Страница 1: ...ult experienced service technicians for disconnection and reinstallation of the unit Do not place any other electrical products or household belongings under indoor unit or outdoor unit Condensation dripping from the unit might get them wet and may cause damage or malfunction of your property Be careful not to scratch the air conditioner when handling it After installation explain correct operatio...

Страница 2: ...onents During repairs to sealed components all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servic ing then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation P...

Страница 3: ...hall be complete with leak free disconnect couplings and in good condition Before using the recovery machine check that it is in satisfactory working order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered refrigerant shall be returned to the refrigerant supp...

Страница 4: ...t piping 4 ELECTRICAL REQUIREMENT The indoor unit is powered from the outdoor unit Do not power indoor unit from separate power source WARNING Standard for electrical wiring and equipment differs in each country or region Before you start electrical working confirm related regulations codes or standards Cable Conductor size mm2 Type Remarks Connection cable 1 5 Type 60245 IEC 57 3 cable Earth Grou...

Страница 5: ... an electric discharge 6 4 Installing the wall hook bracket Remove the wall hook bracket from the indoor unit Remove 2 screws 1 Install the wall hook bracket so that it is correctly positioned horizontally and vertically If the wall hook bracket is titled water will drip to the floor 2 Install the wall hook bracket so that it is strong enough to support the weight of the unit Fasten the wall hook ...

Страница 6: ...r water from entering the pipes Die A Pipe B L Check if L is flared uniformly and is not cracked or scratched Pipe outside diameter mm in Dimension A mm Dimension B mm Flare tool for R32 clutch type 6 35 1 4 0 to 0 5 9 1 9 52 3 8 13 2 12 70 1 2 16 6 15 88 5 8 19 7 19 05 3 4 24 0 When using conventional flare tools to flare R32 pipes the dimension A should be approx imately 0 5 mm more than indicat...

Страница 7: ...lastic jacket portion but not at the insulator portion If the insulator is chafed electric leakage may occur Always connect the earth ground wire Improper earthing grounding work can cause electric shocks Do not use the earth ground screw for the indoor unit to the outdoor unit unless it is specified 7 ELECTRICAL WIRING CAUTION Be careful not to generate a spark as follows for using a flammable re...

Страница 8: ...val 2 Remove 3 caps 3 Remove wire cover 4 Remove 7 screws Screws Wire cover Screws 6 position Caps 3 position Wire cover 5 The front panel is pulled to the front raising the upper surface and a front panel is removed Front panel 9 2 Front panel installation 1 First fit the lower part of the front panel and insert top and bottom hooks 3 top sides 2 center Indoor unit Front panel Latches 2 position ...

Страница 9: ...l kit confirm whether the air conditioner receives the signal from the remote controller Do not connect the wired remote controller to the terminal for power supply When connecting the wired remote controller with the indoor unit use the connecting cable that is supplied with wired remote controller or simple remote controller Recommended cable length of wired remote controller is 10 m When you ex...

Страница 10: ...nd pull off the lock at the side of the connector insertion part CAUTION Be careful not to damage the parts on the board Otherwise it will cause malfunction Connector number CN 5 Connector number CN 4 Connector number CN 10 Connector number CN 7 Symbol indicating the location printed on the board 4 Remove the wires from the three fixtures See the figure below Leave the thick green wire in fixture ...

Страница 11: ... in the oval circles below Then connect the connectors in the squares to the terminals respectively Each terminal should form a pair with a connector CAUTION Ensure that the connector is properly inserted Otherwise it may result in erroneous operation Be careful not to damage the parts on the board Otherwise it will cause malfunction 4 Wired remote controller cable External connect kit cable sold ...

Страница 12: ...ress the RESET button to enter the function setting mode Selecting the Function Number and Setting Value Reverse cycle model 1 Press the TEMP buttons to select the func tion number Press the 10 C HEAT button to switch between the left and right digits 2 Press the POWERFUL button to proceed to setting value Press the POWERFUL button again to return to the function number selection 3 Press the TEMP ...

Страница 13: ... converter the setting cannot be made by using the remote controller Set to 00 or 01 To confirm if the remote controller has this function refer to the operating manual of each remote controller Setting record Record any changes to the settings in the following table Setting Description Setting Value Filter sign Auto restart Room temperature sensor switching Remote controller custom code External ...

Страница 14: ...peration Error display Wired remote controller Error code Description OPERATION lamp green TIMER lamp orange ECONOMY lamp green 1 1 Serial communication error 1 2 Wired remote controller communication error 1 5 Check run unfinished 1 6 Peripheral unit transmission PCB connection error 1 8 External communication error 2 1 Unit number or Refrigerant circuit address setting error Simultaneous Multi 2...

Страница 15: ...rror 9 9 4 way valve error 9 10 Coil expansion valve error 10 1 Discharge temp error 10 3 Compressor temp error 10 4 High pressure error 10 5 Low pressure error 13 2 Branch boxes error Flexible Multi Display mode 0 5s ON 0 5s OFF 0 1s ON 0 1s OFF Number of flashing Troubleshooting with the indoor unit display OPERATION indicator green TIMER indicator orange ECONOMY indicator green Troubleshooting ...

Страница 16: ......

Отзывы: