En-5

7. ELECTRICAL WIRING 

7.1. Wiring system diagram

 WARNING

•  Every wire must be connected 

fi

 rmly.

•  No wire should be allowed to touch refrigerant tubing, the compressor or any mov-

ing part.

•  Loose wiring may cause the terminal to overheat or result in unit malfunction. A 

fi

 re 

hazard may also exist. Therefore, be sure all wiring is tightly connected.

•  Connect wires to the matching numbers of terminals.

Grounding line

Type 60245 IEC57 
(Inter-unit)

OUTDOOR UNIT

Please connect it to 
the speci

fi

 ed terminal.

INDOOR UNIT

TERMINAL

Power line

Control line

7.2.  Indoor unit wiring

1. Remove the cable clamp.
2. Bend the end of the connection cable as shown in the 

fi

 gure.

3. Connect the end of the connection cable fully inserting into the terminal block.
4. Fasten the connection cable with a cable clamp.

Wire cover

Wire cover

Screw

Screw

Screw

Screw

Insert the wire cover tab into the square hole 
of the indoor unit and fasten with a screw.

Connection cable

60 mm

40 mm

Cable clamp

Cable clamp

7.3.  How to connect wiring to the terminals

Caution when wiring cable

When stripping off the insulation of a lead wire, always use a special tool such as a wire 
stripper. If there is no special tool available, carefully strip the insulation with a knife etc.
(1)  Use crimp-type terminals with insulating sleeves as shown in the 

fi

 gure below to con-

nect to the terminal block.

(2)  Securely clamp the crimp-type terminals to the wires using an appropriate tool so that 

the wires do not come loose.

Strip : 10 mm 

Crimp-type 
terminal

Sleeve

(3)  Use the speci

fi

 ed wires, connect them securely, and fasten them so that there is no 

stress placed on the terminals.

(4)  Use an appropriate screwdriver to tighten the terminal screws. Do not use a screw-

driver that is too small, otherwise, the screw heads may be damaged and prevent the 
screws from being properly tightened.

(5)  Do not tighten the terminal screws too much, otherwise, the screws may break.

Screw with special washer

Wire

Crimp-type terminal

Terminal blocks

Wire

Screw with special washer

Crimp-type 

terminal

(6)  See the table below for the terminal screw tightening torques.

Tightening torque [N·m (kgf·cm)]

M4 screw

1.2 to 1.8 (12 to 18)

 CAUTION

•  Match the terminal block numbers and connection cable colors with those of the 

outdoor unit.

Erroneous wiring may cause burning of the electric parts.

•  Connect the connection cables 

fi

 rmly to the terminal block. Imperfect installation may 

cause a 

fi

 re.

•  Always fasten the outside covering of the connection cable with the cable clamp. (If 

the insulator is chafed, electric discharge may occur.)

•  Always connect the ground wire.

•  Do not use the earth screw of the indoor unit for the connection other than a speci

fi

 ed 

outdoor unit.

8. FINISHING 

 (1)  Insulate between pipes.

•  Insulate suction and discharge pipes separately.
•  For rear, right, and bottom piping, overlap the connection pipe heat insulation and 

indoor unit pipe heat insulation and bind them with vinyl tape so that there is no gap.

•  For left and left rear piping, butt the connection pipe heat insulation and indoor unit 

pipe heat insulation together and bind them with and vinyl tape so that there is no gap.

•  For left and left rear piping, wrap the area which accommodates the rear piping 

housing section with cloth tape.

•  For left and left rear piping, bind the connection cable to the top of the pipe with 

vinyl tape.

•  For left and left rear piping, bundle the piping and drain hose together by wrapping 

them with cloth tape over the range within which they 

fi

 t into the rear piping 

housing section.

 (2)  Temporarily fasten the connection cable along the connection pipe with vinyl tape. 

(Wrap to about 1/3 the width of the tape from the bottom of the pipe so that water 
does not enter.)

 (3)  Fasten the connection pipe to the outside wall with a saddle, etc.
 (4)  Fill the gap between the outside wall pipe hole and the pipe with sealer so that rain 

water and wind cannot blow in.

 (5)  Fasten the drain hose to the outside wall, etc.

*Field supplied

Pipe

Saddle*

Outside wall cap*

Sealer putty*

(Outdoors)

Wall

Overlap the insulation

Vinyl tape

Wrap with cloth tape 

Cloth tape

Drain hose

Connection cable

Pipe

Drain hose

Check the following:

GOOD

Drain hose

Saddle

Lifted up

Wave

End in water

Drain hose

Connection pipe

Wall pipe

Connection cable

Left piping

For connection from the left rear

Pipe

Connection pipe 
(heat insulation)

Indoor unit pipe
(heat insulation)

PROHIBITED

Bind the pipes together 
so that there is no gap.

Seal A is used when the diameter 

of gas pipe is Ø12.70 or more.

Butt connection pipe (heat 

insulation) against the indoor 

unit pipe (heat insulation) and 

wrap with seal A so that there 

is no gap.

9333005072_IM.indb   5

9333005072_IM.indb   5

2013-9-24   11:44:39

2013-9-24   11:44:39

Содержание AOYG14LMCBN

Страница 1: ...andling it After installation explain correct operation to the customer using the operating manual 2 ABOUT THE UNIT 2 1 Precautions for using R410A refrigerant The basic installation work procedures are the same as conventional refrigerant R22 models However pay careful attention to the following points Since the working pressure is 1 6 times higher than that of conventional refrigerant R22 models...

Страница 2: ...cause water leaks Use heat insulation with heat resistance above 120 C Reverse cycle model only In addition if the humidity level at the installation location of the refrigerant piping is expected to exceed 70 install heat insulation around the refrigerant piping If the expected humidity level is 70 80 use heat insulation that is 15 mm or thicker and if the expected humidity exceeds 80 use heat in...

Страница 3: ...lied WARNING If the wall pipe is not used the cable interconnecting the indoor unit s and outdoor unit may touch metal and cause electric discharge 6 4 Installing the wall hook bracket Remove the wall hook bracket from the indoor unit Remove 2 screws 1 Install the wall hook bracket so that it is correctly positioned horizontally and vertically If the wall hook bracket is titled water will drip to ...

Страница 4: ...re tool Leakage of refrigerant may result if other flare nuts are used 4 Protect the pipes by pinching them or with tape to prevent dust dirt or water from entering the pipes Die A Pipe B L Check if L is flared uniformly and is not cracked or scratched Pipe outside diameter mm in Dimension A mm Dimension B mm Flare tool for R410A clutch type 6 35 1 4 0 to 0 5 9 1 9 52 3 8 13 2 12 70 1 2 16 6 15 88...

Страница 5: ...nnection cable colors with those of the outdoor unit Erroneous wiring may cause burning of the electric parts Connect the connection cables firmly to the terminal block Imperfect installation may cause a fire Always fasten the outside covering of the connection cable with the cable clamp If the insulator is chafed electric discharge may occur Always connect the ground wire Do not use the earth scr...

Страница 6: ... remote controller START STOP button When the air conditioner is running by pressing the test run button the OPERATION Lamp and TIMER Lamp will simultaneously flash slowly Using the wired remote control Option For the operation method refer to the operating manual 1 Stop the air conditioner operation 2 Press the master control button and the fan control button simultaneously for 2 seconds or more ...

Страница 7: ...ed White Red Black Black Insulated connection Remote controller cord Remote controller cord 20 mm 13 2 Installing wired remote controller terminal external connect kit terminal sold separately 1 Remove the screw on the control box as shown on the top right of the figure below 2 Release both bottom clasps at the sides in the direction of the arrow as circled in the bottom left of the figure below P...

Страница 8: ...fixture 1 location into the control box Control box The installation method of the control box is different for each destination country See figure below When installing reuse the screw that was removed in 13 3 2 Removing control box 2 Secure the control box with a screw Use a long screw 3 2 3 Fasten the earth wires of the heat exchanger together as shown in the left figure above Use a short screw...

Страница 9: ...ner cannot receive a cus tom code if the air conditioner has not been set for the custom code The custom codes that are set through this process are applica ble only to the signals in the FUNCTION SETTING For details on how to set the custom codes through the normal process refer to Remote controller custom code 1 Press SET TEMP button to change the custom code between Match the code on the dis pl...

Страница 10: ...e sensor change the setting to Both 01 Factory setting Setting Description Function Number Setting Value Indoor unit 42 00 Both 01 00 Sensor on the indoor unit is active 01 Sensors on both indoor unit and wired remote controller is active Remote controller custom code Only for wireless remote controller The indoor unit custom code can be changed Select the appropriate custom code Factory setting S...

Страница 11: ...t error 6 2 Outdoor unit main PCB model information error or communication error 6 3 Inverter error 6 4 Active filter error PFC circuit er ror 6 5 Trip terminal L error 6 10 Display PCB microcomputers communication error 7 1 Discharge temp sensor error 7 2 Compressor temp sensor error 7 3 Outdoor unit Heat Ex liquid temp sensor error 7 4 Outdoor temp sensor error 7 5 Suction Gas temp sensor error ...

Страница 12: ......

Отзывы: