- 54 -
WA
LL
MOUN
TED
AOY
G
09-
14LZ
CAN
10. Electrical characteristics
*1: Maximum current is the total current of the indoor unit and the outdoor unit.
*2: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005. As
the regulations of wire size and circuit breaker differ in each country or region, select appropriate
devices complied to the regional standard.
*3: Limit voltage drop to less than 2%. If voltage drop is 2% or more, increase cable conductor size.
Model name
AOYG09LZCAN
AOYG12LZCAN
AOYG14LZCAN
Power
supply
Voltage
V
230~
Frequency
Hz
50
Max operating current *1
A
11.9
14.9
Starting current
A
2.9
4.0
5.3
Wiring
spec. *2
Circuit breaker current
A
15
20
Power cable
mm
2
1.5
3.5—4.0
Connection cable *3
mm
2
1.5
Limited wiring length
m
21