- 47 -
WA
LL
MOUN
TED
AOY
G
09-
14LZ
CAN
6. Capacity compensation rate for pipe length and height
difference
6-1. Models: AOYG09LZCAN and AOYG12LZCAN
NOTE:
Values mentioned in the table are calculated based on the maximum capacity.
COOLING
Pipe length (m)
5
7.5
10
15
20
Height differenc
e
H (m)
Indoor unit is higher than
outdoor unit *1
15
-
-
-
0.877
0.874
10
-
-
0.956
0.891
0.888
7.5
-
0.988
0.960
0.895
0.892
5
1.017
0.992
0.964
0.899
0.895
0
1.025
1.000
0.971
0.906
0.902
Indoor unit is lower than
outdoor unit *2
-5
1.025
1.000
0.971
0.906
0.902
-7.5
-
1.000
0.971
0.906
0.902
-10
-
-
0.971
0.906
0.902
-15
-
-
-
0.906
0.902
HEATING
Pipe length (m)
5
7.5
10
15
20
He
igh
t differ
ence
H (m)
Indoor unit is higher than
outdoor unit *1
15
-
-
-
0.933
0.925
10
-
-
0.981
0.933
0.925
7.5
-
1.000
0.981
0.933
0.925
5
1.017
1.000
0.981
0.933
0.925
0
1.017
1.000
0.981
0.933
0.925
Indoor unit is lower than
outdoor unit *2
-5
1.012
0.995
0.976
0.928
0.920
-7.5
-
0.993
0.974
0.926
0.918
-10
-
-
0.971
0.923
0.916
-15
-
-
-
0.914
0.906
Height difference H
Indoor unit is higher than outdoor unit
*
1
Indoor unit is lower than outdoor unit
*
2
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
H
H
Содержание AOYG09LZCAN
Страница 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE ASYG09LZCA ASYG12LZCA ASYG14LZCA ...
Страница 16: ... 12 WALL MOUNTED ASYG09 14LZCA 5 Wiring diagrams 5 1 Models ASYG09LZCA ASYG12LZCA and ASYG14LZCA ...
Страница 26: ... 22 WALL MOUNTED ASYG09 14LZCA 8 2 Sound level check point Microphone Microphone 1 m 0 8 m ...
Страница 41: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOYG09LZCAN AOYG12LZCAN AOYG14LZCAN ...
Страница 49: ... 45 WALL MOUNTED AOYG09 14LZCAN 5 Wiring diagrams 5 1 Models AOYG09LZCAN and AOYG12LZCAN ...
Страница 50: ... 46 WALL MOUNTED AOYG09 14LZCAN 5 2 Model AOYG14LZCAN ...