- 8 -
W
A
LL
MOU
N
TED
ASYG09-14LZCA
3. Specifications
Type
Wall mounted
Inverter heat pump
Model name
ASYG09LZCA
ASYG12LZCA
ASYG14LZCA
Power supply
230 V ~ 50 Hz
Available voltage range
198—264 V
Capacity
Cooling
Rated
kW
2.50
3.50
4.20
Btu/h
8,500
11,900
14,300
Min.—Max.
kW
0.90—4.65
0.90—4.80
0.90—6.40
Btu/h
3,100—15,800
3,100—16,300
3,100—21,800
Heating
Rated
kW
3.20
4.00
5.40
Btu/h
10,900
13,600
18,400
Min.—Max.
kW
0.90—7.20
0.90—7.40
0.90—8.90
Btu/h
3,100—24,500
3,100—25,200
3,100—30,300
Input power
Cooling
Rated
kW
0.48
0.80
1.05
Max.
0.85
0.99
1.56
Heating
Rated
0.555
0.76
1.17
Max.
1.93
1.94
2.19
Fan
HIGH
W
23
23
32
MED
13
13
20
LOW
9
9
12
QUIET
5
5
6
Current
Cooling
Rated
A
2.7
4.0
4.8
Heating
2.9
3.9
5.3
EER
Cooling
kW/kW
5.21
4.38
4.00
COP
Heating
5.77
5.26
4.62
Power factor
Cooling
%
77
87
95
Heating
83
85
96
Moisture removal
L/h (pints/h)
1.0 (2.1)
1.1 (2.3)
1.7 (3.6)
Maximum operating current *1
Cooling
A
9.4
9.4
9.9
Heating
11.9
11.9
14.9
Fan
Airflow rate
Cooling
HIGH
m
3
/h
830
900
MED
680
780
LOW
580
630
QUIET
380
440
Heating
HIGH
830
900
MED
680
780
LOW
580
630
QUIET
380
500
Type × Q'ty
Cross flow fan × 1
Motor output
W
61
Sound pressure level *2
Cooling
HIGH
dB (A)
42
45
MED
37
40
LOW
32
34
QUIET
23
26
Heating
HIGH
41
44
MED
35
39
LOW
31
33
QUIET
23
27
Heat exchanger type
Dimensions (H × W × D)
mm
Main: 384 × 720 × 30
Sub 1: 84 × 720 × 13.3
Sub 2: 126 × 720 × 13.3
Fin pitch
Main: 1.2, Sub 1 and Sub 2: 1.4
Rows × Stages
Main: 3 × 24, Sub 1: 1 × 4, Sub 2: 1 × 6
Pipe type
Copper tube
Fin type
Aluminum
Enclosure
Material
Polystyrene
Color
White
Approximate color of MUNSELL 5PB 9.25/0.5
Dimensions
(H × W × D)
Net
mm
295 × 940 × 270
Gross
365 × 1,040 × 355
Weight
Net
kg
14
Gross
17
Connection pipe
Size
Liquid
mm (in)
Ø 6.35 (Ø 1/4)
Gas
Ø 9.52 (Ø 3/8)
Ø 12.7 (Ø 1/2)
Method
Flare
Drain hose
Material
PP+LLDPF
Size
mm
Ø 13.8 (I.D.), Ø 15.8 to Ø 16.7 (O.D.)
Operation range
Cooling
°C
18 to 32
%RH
80 or less
Heating
°C
16 to 30
Remote controller type
Wireless (Wired [option])
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/ 19 °CWB, and outdoor temperature of 35 °CDB/ 24 °CWB.
– Heating: Indoor temperature of 20 °CDB/ 15 °CWB, and outdoor temperature of 7 °CDB/ 6 °CWB.
– Pipe length: 5 m, Height difference: 0 m. (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *1: Maximum current is maximum value when operated within the operation range.
• *2: Sound pressure level:
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
Содержание AOYG09LZCAN
Страница 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE ASYG09LZCA ASYG12LZCA ASYG14LZCA ...
Страница 16: ... 12 WALL MOUNTED ASYG09 14LZCA 5 Wiring diagrams 5 1 Models ASYG09LZCA ASYG12LZCA and ASYG14LZCA ...
Страница 26: ... 22 WALL MOUNTED ASYG09 14LZCA 8 2 Sound level check point Microphone Microphone 1 m 0 8 m ...
Страница 41: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOYG09LZCAN AOYG12LZCAN AOYG14LZCAN ...
Страница 49: ... 45 WALL MOUNTED AOYG09 14LZCAN 5 Wiring diagrams 5 1 Models AOYG09LZCAN and AOYG12LZCAN ...
Страница 50: ... 46 WALL MOUNTED AOYG09 14LZCAN 5 2 Model AOYG14LZCAN ...