- 30 -
W
A
LL
MOU
N
TED
ASYG09-14LZCA
Contents of function setting
Each function setting listed in this section is adjustable in accordance with the installation environ-
ment.
NOTE:
Setting will not be changed if invalid numbers or setting values are selected.
Function setting list
1) Filter sign
Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated
amount of dust in the air of the room.
If the indication is not required, select "No indication" (03).
2) Room temperature sensor control for cooling
Depending on the installed environment, correction of the room temperature sensor may be re-
quired. Select the appropriate control setting according to the installed environment.
3) Room temperature sensor control for heating
Depending on the installed environment, correction of the room temperature sensor may be re-
quired. Select the appropriate control setting according to the installed environment.
Function no.
Functions
1)
11
Filter sign
2)
30
Room temperature sensor control for cooling
3)
31
Room temperature sensor control for heating
4)
40
Auto restart
5)
42
Room temperature sensor switching
6)
44
Remote controller custom code
7)
46
External input control
8)
48
Room temperature sensor switching (Aux.)
9)
49
Indoor unit fan control for energy saving for cooling
Function number
Setting value
Setting description
Factory setting
11
00
Standard (400 hours)
01
Long interval (1,000 hours)
02
Short interval (200 hours)
03
No indication
♦
Function number
Setting value
Setting description
Factory setting
30
00
Standard
♦
01
Slightly lower control
02
Lower control
03
Higher control
Function number
Setting value
Setting description
Factory setting
31
00
Standard
♦
01
Lower control
02
Slightly higher control
03
Higher control
Содержание AOYG09LZCAN
Страница 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE ASYG09LZCA ASYG12LZCA ASYG14LZCA ...
Страница 16: ... 12 WALL MOUNTED ASYG09 14LZCA 5 Wiring diagrams 5 1 Models ASYG09LZCA ASYG12LZCA and ASYG14LZCA ...
Страница 26: ... 22 WALL MOUNTED ASYG09 14LZCA 8 2 Sound level check point Microphone Microphone 1 m 0 8 m ...
Страница 41: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOYG09LZCAN AOYG12LZCAN AOYG14LZCAN ...
Страница 49: ... 45 WALL MOUNTED AOYG09 14LZCAN 5 Wiring diagrams 5 1 Models AOYG09LZCAN and AOYG12LZCAN ...
Страница 50: ... 46 WALL MOUNTED AOYG09 14LZCAN 5 2 Model AOYG14LZCAN ...