1. Specifications
Type
Wall mounted
Inverter heat pump
Model name
ASYG07LLCE
ASYG09LLCE
ASYG12LLCE
Power supply
230 V ~ 50 Hz
Available voltage range
198—264 V
Capacity
Cooling
Rated
kW
2.00
2.50
3.40
Btu/h
6,800
8,500
11,600
Min.—Max.
kW
0.9—2.8
0.9—3.0
0.9—3.8
Btu/h
3,100—9,500
3,100—10,200
3,100—13,000
Heating
Rated
kW
2.70
3.00
4.00
Btu/h
9,200
10,200
13,600
Min.—Max.
kW
0.9—3.6
0.9—3.8
0.9—5.0
Btu/h
3,100—12,200
3,100—13,000
3,100—17,000
Input power
Cooling
Rated
kW
0.470
0.730
1.080
Min.—Max.
0.25—1.29
0.25—1.29
0.25—1.40
Heating
Rated
0.620
0.740
1.130
Min.—Max.
0.25—1.63
0.25—1.63
0.25—1.98
Fan
HIGH
W
29
MED
19
LOW
8
QUIET
5
Current
Cooling
Rated
A
2.6
3.5
5.2
Heating
3.0
3.5
5.4
EER
Cooling
kW/kW
4.26
3.42
3.15
COP
Heating
4.35
4.05
3.54
Sensible capacity
Cooling
kW
1.30
1.60
2.20
Power factor
Cooling
%
79
91
91
Heating
90
92
92
Moisture removal
L/h (pints/h)
1.0 (1.8)
1.3 (2.3)
1.8 (3.2)
Maximum operating current *1
Cooling
A
6.0
6.0
6.5
Heating
7.5
7.5
9.0
Fan
Airflow rate
Cooling
HIGH
m
3
/h
720
MED
600
LOW
420
QUIET
325
Heating
HIGH
740
MED
600
LOW
450
QUIET
325
Type × Q'ty
Cross flow fan × 1
Motor output
W
30
Sound pressure level *2
Cooling
HIGH
dB (A)
43
MED
38
LOW
33
QUIET
22
Heating
HIGH
43
MED
38
LOW
33
QUIET
22
Heat exchanger type
Dimensions (H × W × D)
mm
256 × 630 × 20
Fin pitch
1.1
Rows × Stages
2 × 16
Pipe type
Copper tube
Fin type
Aluminum
Enclosure
Material
Polystyrene
Color
White + Pearl white (painted)
Approximate color of Munsell N 9.25/
Dimensions
(H × W × D)
Net
mm
262 × 820 × 206
Gross
263 × 870 × 328
Weight
Net
kg
7.0
Gross
9.5
Connection pipe
Size
Liquid
mm (in)
Ø 6.35 (Ø 1/4)
Gas
Ø 9.52 (Ø 3/8)
Method
Flare
Drain hose
Material
PP+LLDPE
Size
mm
Ø 13.8 (I.D.), Ø 15.8 to Ø 16.7 (O.D.)
Operation range
Cooling
°C
18 to 32
%RH
80 or less
Heating
°C
16 to 30
Remote controller type
Wireless
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
– Pipe length: 5 m, Height difference: 0 m. (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *1: Maximum current is maximum value when operated within the operation range.
• *2: Sound pressure level:
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
DESIGN & TECHNICAL MANUAL
- 2 -
WALL MOUNTED
ASYG07-12LLCE
Содержание AOYG07LLCE
Страница 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE ASYG07LLCE ASYG09LLCE ASYG12LLCE ...
Страница 10: ...3 Wiring diagrams 3 1 Models ASYG07LLCE ASYG09LLCE and ASYG12LLCE 6 WALL MOUNTED ASYG07 12LLCE ...
Страница 16: ...6 2 Sound level check point 0 8 m 1 m Microphone Microphone 12 WALL MOUNTED ASYG07 12LLCE ...
Страница 27: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOYG07LLCE AOYG09LLCE AOYG12LLCE ...
Страница 34: ...5 Wiring diagrams 5 1 Models AOYG07LLCE AOYG09LLCE and AOYG12LLCE 30 OUTDOOR UNIT AOYG07 12LLCE ...
Страница 44: ...12 Accessories Part name Exterior Q ty Part name Exterior Q ty Drain pipe 1 40 OUTDOOR UNIT AOYG07 12LLCE ...