11. Safety devices
Type of
protection
Protection form
Model
AOYG07LLCE
AOYG09LLCE
AOYG12LLCE
Circuit protection
Current fuse (Main PCB)
250 V, 25 A
250 V, 5 A
Fan motor
protection
Terminal protection
program
Activate
100±15 °C
Fan motor stop
Reset
95±10 °C
Fan motor restart
Compressor
protection
Terminal protection
program
(Discharge temp.)
Activate
110 °C
Compressor stop
Reset
After 7 minutes
Compressor restart
- 39 -