7. Safety devices

Type of

protection

Protection form

Model

ASYG07LLCE

ASYG09LLCE

ASYG12LLCE

Circuit protection

Current fuse (PCB*)

250 V, 3.15 A

Fan motor
protection

Thermistor protection
program

Activate

93±5 °C

Fan motor speed down

Reset

93±5 °C

Fan motor speed recover

*PCB: Printed Circuit Board

- 13 -

WALL MOUNTED

ASYG07-12LLCE

Содержание AOYG07LLCE

Страница 1: ...AIR CONDITIONER Wall mounted type DESIGN TECHNICAL MANUAL INDOOR ASYG07LLCE ASYG09LLCE ASYG12LLCE OUTDOOR AOYG07LLCE AOYG09LLCE AOYG12LLCE DR_AS036EF_02 2016 04 06 ...

Страница 2: ...uct specifications and design are subject to change without notice for future improvement For further details please check with our authorized dealer Copyright 2016 2017 Fujitsu General Limited All rights reserved ...

Страница 3: ...pacity 7 4 2 Heating capacity 8 5 Fan performance 9 5 1 Air velocity distributions 9 5 2 Airflow 10 6 Operation noise sound pressure 11 6 1 Noise level curve 11 6 2 Sound level check point 12 7 Safety devices 13 8 Remote controller 14 8 1 Wireless remote controller 14 9 Function settings 17 9 1 Function settings by using remote controller 17 9 2 Custom code setting for wireless remote controller 2...

Страница 4: ...CE and AOYG12LLCE 30 6 Capacity compensation rate for pipe length and height difference 31 6 1 Models AOYG07LLCE and AOYG09LLCE 31 6 2 Model AOYG12LLCE 32 7 Additional charge calculation 33 7 1 Models AOYG07LLCE and AOYG09LLCE 33 7 2 Model AOYG12LLCE 33 8 Airflow 34 8 1 Models AOYG07LLCE and AOYG09LLCE 34 8 2 Model AOYG12LLCE 34 9 Operation noise sound pressure 35 9 1 Noise level curve 35 9 2 Soun...

Страница 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE ASYG07LLCE ASYG09LLCE ASYG12LLCE ...

Страница 6: ...Cooling HIGH dB A 43 MED 38 LOW 33 QUIET 22 Heating HIGH 43 MED 38 LOW 33 QUIET 22 Heat exchanger type Dimensions H W D mm 256 630 20 Fin pitch 1 1 Rows Stages 2 16 Pipe type Copper tube Fin type Aluminum Enclosure Material Polystyrene Color White Pearl white painted Approximate color of Munsell N 9 25 Dimensions H W D Net mm 262 820 206 Gross 263 870 328 Weight Net kg 7 0 Gross 9 5 Connection pip...

Страница 7: ...oling kW 2 0 35 C 2 5 35 C 3 4 35 C Heating Average 2 2 10 C 2 3 10 C 3 2 10 C SEER Cooling kWh kWh 6 70 6 90 6 60 SCOP Heating Average 4 00 4 00 3 80 Annual energy consumption QCE kWh a 104 127 180 QHE Average 770 805 1 179 Sound power level Cooling HIGH dB A 59 59 59 Heating 60 60 60 3 WALL MOUNTED ASYG07 12LLCE ...

Страница 8: ...2 Dimensions 2 1 Models ASYG07LLCE ASYG09LLCE and ASYG12LLCE 262 12 10 49 6 5 6 5 49 44 820 355 345 91 312 321 96 72 48 Outline of unit Unit mm 820 262 206 4 WALL MOUNTED ASYG07 12LLCE ...

Страница 9: ...Installation space requirement Provide sufficient installation space for product safety Unit mm 63 or more 70 or more Outline of unit 100 or more 1 500 or more 1 800 or more 5 WALL MOUNTED ASYG07 12LLCE ...

Страница 10: ...3 Wiring diagrams 3 1 Models ASYG07LLCE ASYG09LLCE and ASYG12LLCE 6 WALL MOUNTED ASYG07 12LLCE ...

Страница 11: ...P TC SHC IP kW kW kW kW kW kW kW 20 2 34 1 62 0 51 2 61 1 63 0 52 2 70 1 77 0 52 2 87 1 78 0 53 2 96 1 92 0 53 3 14 1 91 0 54 3 32 2 04 0 54 25 2 22 1 54 0 58 2 48 1 55 0 58 2 56 1 68 0 59 2 73 1 69 0 59 2 81 1 82 0 60 2 98 1 82 0 60 3 15 1 93 0 61 30 2 10 1 45 0 64 2 34 1 46 0 65 2 42 1 59 0 65 2 58 1 60 0 66 2 66 1 72 0 66 2 82 1 72 0 67 2 98 1 83 0 68 35 1 98 1 37 0 70 2 20 1 38 0 72 2 28 1 50 ...

Страница 12: ...3 10 11 2 72 1 18 2 66 1 21 2 59 1 23 2 53 1 25 2 46 1 28 5 7 2 96 1 16 2 88 1 19 2 81 1 21 2 74 1 24 2 67 1 26 0 2 3 39 1 20 3 31 1 22 3 23 1 25 3 14 1 27 3 06 1 30 5 3 3 82 1 23 3 73 1 25 3 64 1 28 3 54 1 30 3 45 1 33 7 6 3 99 1 24 3 90 1 27 3 80 1 29 3 71 1 32 3 61 1 34 10 8 3 94 1 18 3 84 1 21 3 75 1 23 3 66 1 26 3 56 1 28 15 10 4 11 1 19 4 01 1 22 3 91 1 24 3 81 1 27 3 71 1 29 Model ASYG12LLC...

Страница 13: ... 4 5 6 7 8 Top view Vertical airflow direction louver Up Horizontal airflow direction louver Left Right 2 0 1 0 1 0 0 5 0 5 3 2 1 0 1 2 3 Unit m s m m 0 1 2 3 4 5 6 7 8 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center 2 0 1 0 0 5 3 2 1 0 Unit m s m m 0 1 2 3 4 5 6 7 8 Side view Vertical airflow direction louver Down Horizontal airflow direction louver Cente...

Страница 14: ... m3 h 720 l s 200 CFM 424 MED m3 h 600 l s 167 CFM 353 LOW m3 h 420 l s 117 CFM 247 QUIET m3 h 325 l s 90 CFM 191 Heating Fan speed Airflow HIGH m3 h 740 l s 206 CFM 436 MED m3 h 600 l s 167 CFM 353 LOW m3 h 450 l s 125 CFM 265 QUIET m3 h 325 l s 90 CFM 191 10 WALL MOUNTED ASYG07 12LLCE ...

Страница 15: ... 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Model ASYG12LLCE Cooling NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 HIGH QUIET Heating Octave band sound ...

Страница 16: ...6 2 Sound level check point 0 8 m 1 m Microphone Microphone 12 WALL MOUNTED ASYG07 12LLCE ...

Страница 17: ...SYG07LLCE ASYG09LLCE ASYG12LLCE Circuit protection Current fuse PCB 250 V 3 15 A Fan motor protection Thermistor protection program Activate 93 5 C Fan motor speed down Reset 93 5 C Fan motor speed recover PCB Printed Circuit Board 13 WALL MOUNTED ASYG07 12LLCE ...

Страница 18: ... on the indoor unit will begin to flash simultaneously To stop the test operation mode press the START STOP button Then the air conditioner stops the operation k ECONOMY button l POWERFUL button m SET TEMP temperature button Sets desired temperature Sets remote controller custom code n MODE button Switches operation mode AUTO COOL DRY FAN and HEAT Starts ends the remote controller custom code max ...

Страница 19: ...NOTE Functions may differ by type of the indoor unit For details refer to the operation manual 15 WALL MOUNTED ASYG07 12LLCE ...

Страница 20: ...w Rear view 139 18 56 Top view Size H W D mm 139 56 18 Weight g 70 without batteries Holder Unit mm Front view Side view Bottom view 60 4 30 2 Ø 3 5 3 5 x 6 5 hole hole 13 5 92 26 2 140 Size H W D mm 140 60 4 26 2 Weight g 25 16 WALL MOUNTED ASYG07 12LLCE ...

Страница 21: ...e been performed firmly There is no wiring mistake Then connect the power supply of indoor unit Entering function setting mode While pressing the FAN button and SET TEMP button simultaneously press the RESET button to enter the function setting mode STEP 1 Setting the remote controller custom code Use the following steps to select the custom code of the remote controller Note that the air con diti...

Страница 22: ... proceed the setting value To return the function number selection press the FAN button again 3 Press the SET TEMP buttons to select the setting value To switch between the left and right digits press the MODE but ton 4 Press the SLEEP button then after you hear the beep emitted from the indoor unit the START STOP button in the order to con firm the settings 5 Press the RESET button to cancel the ...

Страница 23: ...on number Setting value Setting description Factory setting 11 00 Standard 400 hours 01 Long interval 1 000 hours 02 Short interval 200 hours 03 No indication 2 Room temperature sensor control for cooling Depending on the installed environment correction of the room temperature sensor may be re quired Select the appropriate control setting according to the installed environment Function number Set...

Страница 24: ...ed Select the appropriate custom code Function number Setting value Setting description Factory setting 44 00 A 01 B 02 C 03 D 6 Indoor unit fan control for energy saving for cooling Enables or disables the power saving function by controlling the indoor unit fan rotation when the outdoor unit is stopped during cooling operation Function number Setting value Setting description Factory setting 49 ...

Страница 25: ...om code 3 Press the MODE button again The custom code will be changed NOTES If no button is pressed within 30 seconds after the custom code is displayed the system re turns to the original clock indicator In this case start again from step 1 The air conditioner custom code is set to prior to shipment To change the custom code contact your retailer The remote controller resets to custom code when t...

Страница 26: ...s Part name Exterior Q ty Part name Exterior Q ty Operating manual 1 Battery 2 Installation manual 1 Cloth tape 1 Wall hook bracket 1 Tapping screw large M4 25 mm 5 Remote controller 1 22 WALL MOUNTED ASYG07 12LLCE ...

Страница 27: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOYG07LLCE AOYG09LLCE AOYG12LLCE ...

Страница 28: ...l Steel sheet Color Beige Approximate color of MUNSELL 10YR7 5 1 0 Dimensions H W D Net mm 535 663 293 Gross 595 790 395 Weight Net kg 24 26 Gross 27 29 Connection pipe Size Liquid mm in Ø 6 35 Ø 1 4 Gas Ø 9 52 Ø 3 8 Method Flare Pre charge length m 15 Max length 20 Max height difference 15 Operation range Cooling C 10 to 43 Heating 15 to 24 Drain hose Material LDPE Size mm Ø 13 0 I D Ø 16 0 to Ø ...

Страница 29: ...2 Dimensions 2 1 Models AOYG07LLCE AOYG09LLCE and AOYG12LLCE Top view Unit mm Front view Side view 20 663 68 293 Drain hole 30 330 454 Pitch of bolt 103 535 15 48 352 330 25 OUTDOOR UNIT AOYG07 12LLCE ...

Страница 30: ...tacles at the rear and sides 100 or more 250 or more 100 or more 100 or more When there are obstacles at the front only When there are obstacles at the front and rear 600 or more 600 or more 100 or more When there is an obstruction in the upper space Unit mm When there are obstacles at the rear and above When there are obstacles at the rear sides and above 100 or more Max 200 600 or more 600 or mo...

Страница 31: ...nly When there are obstacles at the front only 200 or more 1 000 or more When there are obstacles at the front and rear 200 or more 1 000 or more When there is an obstruction in the upper space Unit mm When there are obstacles at the rear and above 1 500 or more 200 or more Max 300 27 OUTDOOR UNIT AOYG07 12LLCE ...

Страница 32: ...N Do not install the outdoor unit in two stage where the drain water could freeze Otherwise the drainage from the upper unit may form ice and cause a malfunction of the lower unit When the outdoor temperature is 0 C or less do not use the accessory drain pipe and drain cap If the drain pipe and drain cap are used the drain water in the pipe may freeze in ex tremely cold climate For reverse cycle m...

Страница 33: ...R ThHO ThHO ThO ThO 3 way valve Muffler Cooling Heating Thermistor Discharge temperature Thermistor Outdoor temperature Thermistor Heat exchanger out temperature Thermistor Room temperature Thermistor Pipe temperature Compressor 4 way valve Strainer Expansion valve Strainer 2 way valve 29 OUTDOOR UNIT AOYG07 12LLCE ...

Страница 34: ...5 Wiring diagrams 5 1 Models AOYG07LLCE AOYG09LLCE and AOYG12LLCE 30 OUTDOOR UNIT AOYG07 12LLCE ...

Страница 35: ... unit 1 15 0 872 0 910 10 0 961 0 886 0 925 7 5 0 979 0 965 0 890 0 929 5 0 992 0 983 0 969 0 893 0 933 0 1 000 0 991 0 976 0 901 0 940 Indoor unit is lower than outdoor unit 2 5 1 000 0 991 0 976 0 901 0 940 7 5 0 991 0 976 0 901 0 940 10 0 976 0 901 0 940 15 0 901 0 940 HEATING Pipe length m 5 7 5 10 15 20 Height difference H m Indoor unit is higher than outdoor unit 1 15 0 832 0 822 10 0 917 0 ...

Страница 36: ...Indoor unit is lower than outdoor unit 2 5 1 000 0 972 0 944 0 887 0 896 7 5 0 972 0 944 0 887 0 896 10 0 944 0 887 0 896 15 0 887 0 896 HEATING Pipe length m 5 7 5 10 15 20 Height difference H m Indoor unit is higher than outdoor unit 1 15 0 896 0 879 10 0 968 0 890 0 879 7 5 0 994 0 968 0 896 0 879 5 1 000 0 994 0 968 0 896 0 879 0 1 000 0 994 0 968 0 896 0 879 Indoor unit is lower than outdoor ...

Страница 37: ...gerant amount g 650 Refrigerant charge Total pipe length m 15 or less 20 Max 20 g m Additional charge g 0 100 7 2 Model AOYG12LLCE Refrigerant type R410A Refrigerant amount g 850 Refrigerant charge Total pipe length m 15 or less 20 Max 20 g m Additional charge g 0 100 33 OUTDOOR UNIT AOYG07 12LLCE ...

Страница 38: ...s AOYG07LLCE and AOYG09LLCE Cooling m3 h 1 670 l s 464 CFM 983 Heating m3 h 1 470 l s 408 CFM 865 8 2 Model AOYG12LLCE Cooling m3 h 1 830 l s 508 CFM 1 077 Heating m3 h 1 600 l s 444 CFM 942 34 OUTDOOR UNIT AOYG07 12LLCE ...

Страница 39: ... 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Model AOYG09LLCE Cooling Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Heating Octave band sound pressure level dB 0...

Страница 40: ... 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Heating Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 36 OUTDOOR UNIT AOYG07 12LLCE ...

Страница 41: ...evel check point 1 m Microphone Microphone Rear Airflow Rear view Side view NOTE Detailed shape of the actual outdoor unit might be slightly different from the one illustrat ed above 37 OUTDOOR UNIT AOYG07 12LLCE ...

Страница 42: ...m2 1 5 Limited wiring length m 21 1 Maximum current is the total current of the indoor unit and the outdoor unit 2 Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005 As the regulations of wire size and circuit breaker differ in each country or region select appropri ate devices complied to the regional standard 3 Limit voltage drop to less than 2 If voltage drop is...

Страница 43: ...nt fuse Main PCB 250 V 25 A 250 V 5 A Fan motor protection Terminal protection program Activate 100 15 C Fan motor stop Reset 95 10 C Fan motor restart Compressor protection Terminal protection program Discharge temp Activate 110 C Compressor stop Reset After 7 minutes Compressor restart 39 OUTDOOR UNIT AOYG07 12LLCE ...

Страница 44: ...12 Accessories Part name Exterior Q ty Part name Exterior Q ty Drain pipe 1 40 OUTDOOR UNIT AOYG07 12LLCE ...

Отзывы: