7. TROUBLESHOOTING
07-01
7-1 ERROR DISPLAY
Run [Self-Diagnosis] if [E:EE] flashes on the clock display of the remote controller.
When the error indication "E:EE" is displayed, inspection of the air conditioning system is necessary.
Please consult authoilzed servise personnel.
Error code
Error contents
Trouble
shooting
Communication error (Serial reverse transfer error)
Room temperature sensor open
Room temperature sensor short-circuited
Indoor heat exchanger temperature sensor open
Indoor heat exchanger temperature sensor short-circuited
Outdoor heat exchanger temperature sensor error
Water drain abnormal
Outdoor temperature sensor error
Outdoor discharge pipe temperature sensor error
Indoor EEPROM abnormal (Model No.)
Indoor fan motor abnormal
Outdoor unit fan motor error
Outdoor communication signal error (Forward transfer signal error)
Ex. Self-diagnosis
Error code
SU MO TU WE TH FR SA
DAY OFF
DELETE
SET
ENERGY
SAVE
SET BACK
DAY
CLOCK ADJUST
Display
DAY OFF
DELETE
SET
ENERGY
SAVE
SET BACK
DAY
CLOCK ADJUST
SET
1. Stop the air conditioner operation.
2. Press the SET TEMPERATURE buttons and simultaneously for 5 seconds or more
to start the self-diagnosis.
3. Press the SET TEMPERATURE buttons and simultaneously for 5 seconds or more
or there is no key input for 20 seconds to stop the self-diagnosis.
SU MO TU WE TH FR SA
7-1-1 WIRED REMOTE CONTROLLER DISPLAY
THERMO
SENSOR
Pressure switch error
Active filter module (AFM) error
CT error
Communication error
(indoor unit remote control)
IPM error
Compressor rotor location cannot detect
(permanent stop)
Compressor temperature sensor
error
1. SELF - DIAGNOSIS
1
2
5
6
7
8
9
10
11
12
13
14
15
16
17
18
3
4
Содержание AO*24LMAKL
Страница 5: ...1 SPECIFICATIONS R410A CASSETTE type INVERTER ...
Страница 11: ...2 DIMENSIONS R410A CASSETTE type INVERTER ...
Страница 15: ...3 REFRIGERANT SYSTEM DIAGRAM R410A CASSETTE type INVERTER ...
Страница 19: ...4 CIRCUIT DIAGRAM R410A CASSETTE type INVERTER ...
Страница 25: ...5 DESCRIPTION OF EACH CONTROL OPERATION R410A CASSETTE type INVERTER ...
Страница 47: ...6 REFRIGERANT CAUTION R410A R410A CASSETTE type INVERTER ...
Страница 56: ...7 TROUBLE SHOOTING R410A CASSETTE type INVERTER ...
Страница 91: ...8 APPENDING DATA R410A CASSETTE type INVERTER ...
Страница 110: ...9 INSTALLATION MANUAL R410A CASSETTE type INVERTER ...
Страница 117: ...10 REPLACEMENT PARTS R410A CASSETTE type INVERTER ...
Страница 119: ...Thermistor Heat exchanger temp 2 way valve Liquid 3 way valve Gas 10 02 Thermo Holder Thermistor Outdoor Temp ...
Страница 143: ...2 TOP PANEL removal Remove the 7 mounting screws Remove the TOP PANEL upward FRONT VIEW REAR VIEW 10 26 ...
Страница 158: ...10 41 8 DRAIN PAN removal Remove the DRAIN PAN ASSY DRAIN PAN ASSY ...
Страница 161: ...10 44 11 DRAIN PUMP removal Remove the 2 mounting screws Remove the DRAIN PUMP UNIT DRAIN PUMP UNIT DRAIN HOSE ...
Страница 162: ...1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan Apr 2006 Printed in Japan ...