2. HEATING OPERATION
2-1 HEATING CAPACITY CONTROL
A sensor (room temperature thermistor) built in the indoor unit body will usually perceive
difference or variation between a set temperature and present room temperature, and
controls the operation frequency of the compressor.
* If the room temperature is lower by 3°C than a set temperature, the compressor operation
frequency will attain to maximum performance.
* If the room temperature is higher 2.5°C than a set temperatire, the compressor will be
stopped.
Outside air
temperature
Outside air
temperature
19°C
C zone
17°C
14°C
B zone
12°C
A zone
AA zone
7°C
5°C
* When the room temperature is b2°C to -3°C of the setting temperature,
the compressor frequency is controlled within the range shown in Table2.
However, the maximum frequency is limited in the range shown in Figure 2 based on the
fan speed mode and the outdoor temperature.
( Table 2 : Compressor Frequency Range )
( Fig.2 : Limit of Maximum Frequency based on Outdoor Temperature )
* The room temperature is controlled 2°C higher than the setting temperature for 60 minutes
after starting the operation.
After 60 minutes, it is controlled based on the normal setting temperature.
05-02
minimum
frequency
air flow
maximum
frequency
AG*V09LAC
18Hz
18Hz
130Hz
119Hz
AG*V12LAC
AG*V14LAC
Hi
Me
Lo
Quiet
130Hz
96Hz
57Hz
45Hz
130Hz
96Hz
64Hz
51Hz
80Hz
68Hz
130Hz
96Hz
Upper&
Lower
air flow
Upper
air flow
130Hz
96Hz
80Hz
68Hz
130Hz
96Hz
48Hz
33Hz
130Hz
96Hz
64Hz
45Hz
80Hz
51Hz
130Hz
96Hz
130Hz
96Hz
80Hz
68Hz
AA zone
A zone
B zone
C zone
AA zone
A zone
B zone
C zone
Upper & Lower
Upper
Upper & Lower
Upper
AG*V09/ 12LAC
Hi
Me
Lo
Quiet
119Hz
90Hz
54Hz
30Hz
119Hz
90Hz
70Hz
38Hz
70Hz
45Hz
119Hz
90Hz
Upper&
Lower
air flow
Upper
air flow
119Hz
90Hz
70Hz
54Hz
119Hz
90Hz
38Hz
30Hz
119Hz
90Hz
42Hz
38Hz
49Hz
38Hz
119Hz
90Hz
119Hz
90Hz
54Hz
45Hz
AA zone
A zone
B zone
C zone
AA zone
A zone
B zone
C zone
AG*V14LAC
Содержание AG * V12LAC Series
Страница 4: ...1 SPECIFICATIONS R410A FLOOR type INVERTER ...
Страница 6: ...2 DIMENSIONS R410A FLOOR type INVERTER ...
Страница 9: ...3 REFRIGERANT SYSTEM DIAGRAM R410A FLOOR type INVERTER ...
Страница 11: ...4 CIRCUIT DIAGRAM R410A FLOOR type INVERTER ...
Страница 12: ...CIRCUIT DIAGRAM Models AG V09LAC AO V09LAC AG V12LAC AO V12LAC 04 01 INDOOR UNIT OUTDOOR UNIT ...
Страница 13: ...CIRCUIT DIAGRAM Models AG V14LAC AO V14LAC 04 02 INDOOR UNIT OUTDOOR UNIT ...
Страница 14: ...5 DESCRIPTION OF EACH CONTROL OPERATION R410A FLOOR type INVERTER ...
Страница 35: ...6 REFRIGERANT CAUTION R410A R410A FLOOR type INVERTER ...
Страница 62: ...9 REPLACEMENT PARTS R410A FLOOR type INVERTER ...
Страница 80: ...10 INSTALLATION MANUAL R410A FLOOR type INVERTER ...
Страница 89: ...1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan May 2007 Printed in Japan ...