1. External cause
2. Main PCB defective
Trouble shooting 20
EEPROM Access Error
Outdoor unit Main PCB
When the check run if can not write data to the EEPROM.
Detective Actuators:
Detective details:
Indicate of Display:
Forecast of Cause:
02-35
OUTDOOR UNIT Error Method:
・
YES
NO
Test 1-2 : External cause
Check if temporary voltage drop was not generated.
Check if temporary open was not generated.
Check if ground is connected correctly or
there are no related cables near the power line.
Test 1-1 : Turn the power on again?
Error displayed again?
Test 2 :
Replace Main PCB
If Test 1 do not improve the symptom, replace Main PCB(Outdoor unit).
(SERVICE PARTS INFORMATION 10)
Indoor Unit
Outdoor Unit
Operation lamp : - time Flash
ERROR CODE : [E : --]
Timer lamp
: - time Flash
Monitor
A
B
C
D
E
F
6
: Light ON
: Light OFF
n : n time blinking
2